10.   To disconnect, turn all controls to the off position, then remove plug from outlet.

 

WARNING

 - Risk of Electric Shock:

1.   Connect this table to a proper outlet only. For loading always put heavier items at the bottom and not at the top in 

order to help prevent the possibility of the furnishing tipping over.

 

WARNING

 - Risk of Injury to Persons:

1.   Do not use this table to lift people and do not use the table to lift heavy parts or use this table as a platform for storage.

2.   Maximum intended load is 265 pounds uniformly distributed (120 kilograms) including the table top.

 

DANGER

 - Risk of electric shock, injury, or death:

1. 

 Improper usage, abuse, or misuse of the power supply, handset, motors and other electrical components may result in 

an electrical shock injury or possible death.

2.   Do not open the power supply unit or handset under any circumstances. The power supply and handset contain no 

serviceable parts.

3.   Do not modify or make any changes to the power supply, handset or other electrical devices.

4.   During installation, repair, cleaning, or maintenance work, the power cable must be disconnected from the outlet.

5.   The engines/motors control unit is not designed for continuous operation. Changing the desktop position without 

interruption must not exceed the duty cycle indicated on the power supply. The unit is thermally protected and will 

temporarily shut down if use exceeds the duty cycle. Allow a 9-minute cooling period for the control unit to reset.

6.   The power supply unit may only be operated with voltage as specified on the power supply label.

7.   Only use the power cord supplied with the power supply. Check that it is not damaged. Do not operate the power 

supply unit if the power cord is damaged.

8.   Connect the power supply to a proper outlet only. To disconnect turn all controls to the off position, then remove plug 

from outlet.

9.   In the event of a malfunction (e.g. if the control unit keeps adjusting the desk because a movement button has jammed), 

please unplug the unit immediately.

10.   Do not expose the power supply, control unit/ECS+, handset or other electrical device to water or other liquids 

including moisture, drips, splashes or spills. Only clean electrical device with a dry cloth.

11.   Do not operate the power supply, control unit/ECS+, handset or other electrical device in a potentially explosive 

atmosphere. Do not operate where aerosol spray products are being used or where oxygen is being administered.

12.   Do not use the desk with if it has been dropped or damaged. Contact the manufacturer for examination or repair

13.  It is not allowed to connect self-constructed products to the power supply, control unit/ECS+, handset or other 

electrical device. To prevent damage, use only approved OEM components

 

WARNING

 - Risk of injury, or death:

1.   During the raising or lowering of the table there exists a risk of squeezing or pinching between the moving desktop and 

fixed objects.

2.   The necessary safety margins depend on the greatest type of injury risk that can be predicted. Where possible small 

pinch points exist (i.e. fingers) use at least a one inches (2,5 cm) safety margin and for body or head (especially where 

children may be present) use a minimum of 16 inches (41 cm) count from the floor or from their top of the table feet if 

that is relevant

3.   During the lowering or rising of the desktop, the operator must ensure that no person or object risk being harmed by 

the operation.

Summary of Contents for FOLI MECHANISM WITH ECS+

Page 1: ...manual FOLI USER FOLI MECHANISM WITH ECS ...

Page 2: ...tart 6 1 4 Electrical rating 6 2 Assembly Adjustment 6 2 1 Assembly Instruction 6 2 2 Setup procedure 6 2 3 Optional mounting guidelines 7 2 4 System configuration example 7 2 5 Adjustments 7 3 Operation Instructions 8 3 1 Basic functions 8 4 Maintenance Repairs 12 4 1 Cleaning Inspection and Storage 12 4 2 User Maintenance 12 4 3 Repairs 12 4 4 Servicing of double insulated products 13 2 ...

Page 3: ...equipment function and to avoid equipment damage or wear The information and specifications included in this manual were in effect at the time of approval for printing ROL reserves the right to discontinue or change specifications or design at anytime without notice and without incurring any obligation whatever 1 1 Important safety instructions please save these instruction When using an electrica...

Page 4: ...ord supplied with the power supply Check that it is not damaged Do not operate the power supply unit if the power cord is damaged 8 Connect the power supply to a proper outlet only To disconnect turn all controls to the off position then remove plug from outlet 9 In the event of a malfunction e g if the control unit keeps adjusting the desk because a movement button has jammed please unplug the un...

Page 5: ...f pinch points when the desktop is moving 11 This table is not intended for use by individuals including children with limited physical sensory or mental abilities or with a lack of experience and or lack of expertise unless they are supervised by a person responsible for their safety or have received instructions from that person on how to use the control unit 12 Children must be supervised at al...

Page 6: ...th an approved surface provided by the Global Furniture Group 2 2 Setup procedure CAUTION Risk of electrical shock The power cord must be unplugged while the control unit is being commissioned This table is equipped with the ECS system to setup the controlling device proceed as follows 1 Connect the motor cables to the control unit 8 pin motor cables 2 Connect the handset to the relevant socket at...

Page 7: ...t installed by a qualified electrician This product is designed for the voltage indicated on the power supply label No adapters should be used with this product CAUTION Risk of electrical shock Before you plug in the power cord check the following again The voltage must be as specified on the power supply label When the power cord is plugged in the electrical control devices are operational NOTICE...

Page 8: ...read the user manual carefully before installing or operating the control unit Overload protection If the total load on the equipment is to high you will only be able to drive for 2 seconds The system will then stop and you need to release the table from load before new drive After load release press button again Overheat protection If heavy loaded and driven continuously for a long period of time...

Page 9: ... In that case press the Down button until the symbol goes away ECS ECS for ECS Software will show the software version of the ECS box Version is shown as Year and Week Y W Press Up and Down buttons simultaneously to enter the Settings menu Press Up button until you reach ECS To enter press Up and Down buttons simultaneously The version of the software is now shown on the display To exit setting pr...

Page 10: ...he Settings menu Press Up button until you reach SOF To enter press Up and Down button simultaneously The version of the software is now shown on the display To exit setting press Up and Down buttons simultaneously rES Reset rES for Reset will force the sytem into Reset mode Press Up and Down buttons simultaneously to enter the Settings Menu Press Up button until you reach rES To enter press Up an...

Page 11: ...e Lower limit Reset Mode Press and hold Up and Down buttons simultaneously for 8 seconds this will initiate the Reset mode SL Simple Memory Lower SL for Simple Memory Lower You are able to set a stored Simple Memory for the Down button The desk will stop at this set height when driving downwards Press Up and Down buttons simultaneously to enter the Settings menu Press Up button until you reach SL ...

Page 12: ...nit is replaced a manual reset is required Follow these steps as section 3 2 If the table is still not operational please contact your vendor for further assistance The control system is equipped with safety features the intermittency function and the overheating protection and memory function Overheat protection The table will become inoperable if the overheating protection is triggered and will ...

Page 13: ...means is provided on a double insulated product nor is a means for grounding to be added to the product Servicing a double insulated product requires extreme care and knowledge of the system and is to be done only by qualified service personnel Replacement parts for a double insulated product must be identical to the parts they replace A double insulated product is marked with the words DOUBLE INS...