Power Specifications 

The supply voltage for the Multi Pulse Counter should be between 3.5 

 5 V

DC

. A 5 V

DC

(up to 1A) adapter 

is provided with the package, however, a similarly rated adapter can be used for supplying power if need 
be.  There  is  provision  for  a  non-rechargeable  battery  to  supply  power  to  the  device  during  a  power 
outage to ensure uninterrupted operation, more information in the following section.  

 

Battery Specifications 

A non-rechargeable Lithium Thionyl Chloride Battery is provided with the device for back up during an 
outage. The C-size battery is rated at 9000 mAH with an output of 3.6V. The Multi Pulse Counter can run 
upto 30 days on battery backup in an idle state. When the Multi Pulse Counter is running on battery it 
will continue  to count  pulses  until  the  battery  dies. While running on battery, we estimate  the device 
can  countto  1  million  pulses  before  it  runs  out  of  charge.  The  actual  battery  backup  time  may  vary 
depending on the input pulse frequency and the remaining charge on the battery. Once the battery is 
completely drained, the user will receive an alert on the LCD once the device is powered on. The battery 
can be easily replaced by removing the drained battery replacing it with a new one. 

Enclosure Specifications 

Global  Power  Product’s 

Multi  Pulse  Counter  is  enclosed  in  a  reliable,  weatherproof  NEMA  4x-rated 

enclosure as shown in figure 1. The dimensions of the enclosure are 10.6 x 8 x 3.3 in. The NEMA-rated 
enclosure  works  both  indoors  and  outdoorsby  protecting  against  foreign  objects  like  dust  and  the 
damaging effects of water. The enclosure will be undamaged by the external formation of ice. However, 
the opening at the bottom of the enclosure must be sealed by the user to retain the waterproof ability 
when in use. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1: Enclosure Dimensions

 

Summary of Contents for Multi Pulse Counter

Page 1: ...lti Pulse Counter 16 Port Smart Monitoring System 225 Arnold Road Lawrenceville GA 30044 Phone 800 886 3837 Email nemeter globalpowerproducts com Installation Operation Manual Version 1 10 October 202...

Page 2: ...ersion number Global Power Products Inc reserves the right to revise this publication and to make any modifications to its content at any time without obligation to notify any party person or entity o...

Page 3: ...mplied including any implied warranty of merchantability or fitness for a particular purpose GlobalPower Products shall not be liable for any indirect special or consequential damages arising from any...

Page 4: ...Pulse Counter Input Specifications 6 Power Specifications 7 Battery Specifications 7 Enclosure Specifications 7 Product Code Structure 8 Mounting Instructions 9 Setup Instructions 9 Operation 10 Mult...

Page 5: ...ure 5 Adjusting the contrast by rotating the adjustment screw 11 Figure 6 Show the login page of the Multi Pulse Counter data server 12 Figure 7 Multi Pulse Counter data webpage showing the number of...

Page 6: ...DC Power Supply 1 Multi Pulse Management Website Login informationand manual 1 Table 1 Contents inside the shipped package Principle of Operation The Multi PulseCounter is an electronic pulse counter...

Page 7: ...xplosion and burnhazards For more information on the battery backup and operation kindly visit Battery Specifications on Page 3 Pulse Counter Input Specifications Input Voltage 0 24 VDC Maximum Count...

Page 8: ...ile running on battery we estimate the device can countto 1 million pulses before it runs out of charge The actual battery backup time may vary depending on the input pulse frequency and the remaining...

Page 9: ...l be labeled as MPC DD WF Along with the model number each specific Multi Pulse Counter has a unique serial number used for identification purposes The configuration dry wet of each input terminal blo...

Page 10: ...negative wire to the position marked Black for each terminal block In case of a dry passive pulse from a mechanical switch the wires can be connected either way to each terminal block In case of a dry...

Page 11: ...e displayed to indicate how much charge is left on the battery If a communication module has been installed on the device a record of the counts will be uploaded to the Multi Pulse Counter management...

Page 12: ...lat screwdriveras shown in figure 4 Figure 5 Adjusting the contrast by rotating the adjustment screw MultiPulse Counter Management Website Instructions The data uploaded by the Multi Pulse Counter can...

Page 13: ...n the Click Here to Download icon The data can also be viewed in a graphical format by clicking on the Graph button on the left side of the webpage You can select any input from the drop down menu alo...

Page 14: ...the name of each input so that tracking each device is simple Figure 9 Multi Pulse Counter webpage with the available customizable options for the users Finally all the groups in this account will be...

Page 15: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not i...

Page 16: ...tenna s used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co located or operating in conjunction with any other antenna or...

Reviews: