Global Power Products Multi Pulse Counter Installation & Operation Manual Download Page 6

 

About This Guide 

This document  is a manual designed to help guide  you through the  installation and operation of your 
MultiPulse Counter. This manual provides detailed guidelines and instructions on features and operating 
characteristics  of  the  MultiPulse  Counter  for  installation,  programming,  communication,  and 
troubleshooting. 

Use these instructions to assemble the MultiPulse Counter.  Read all instructions before you begin the 
installation. The MultiPulse Counter is designed for a variety of monitoring situations. It can be used as a 
stand-alone  pulse  counter  or  part  of  a  network  of  pulse  counters.  If  this  meter  is  to  be  used  with  an 
automated system using WIFI, Ethernet, or RF Communications, refer to the specific instruction of each 
communication option. 

 

Contents of the Package 

The  Multi  Pulse  Counter  is  shipped  from  the  factory  in  a  kit  containing  all  the  hardware  needed  to 
assemble the monitoring system.   

Each box contains: 

Description 

Quantity 

Multi Pulse Counter with Electronics Installed in a Flush Mount Enclosure 

9V DC Battery 

5V 1W DC Power Supply 

Multi Pulse Management Website Login informationand manual. 

Table 1: Contents inside the shipped package. 

 

Principle of Operation 

The  Multi  PulseCounter  is  an  electronic  pulse  counter  capable  of  counting  dry(passivecontact 
open/closed)  andwet(active  contact  up  to  +24  VDC)  pulses.  The  deviceincorporatesa20Hzlow  pass 
filterto  ignore  any  unintended  noise  on  the  input  lines.  Pulses  with  width  fewerthan  50ms  will  be 
disregardedcompletely.  The  recorded  data  is displayed viaan8x2 character LCD  that is visible from the 
outside of the enclosure.The Multi PulseCounter can be customized to upload data to the management 
website wirelessly using Wi-Fi, LTE Cat-M1, or through a wired Ethernet connection. If multiple devices 
are  used  together,  a  wireless  RF  network  can  be  created  where  each  device  communicates  with 
onecentralsmart  gateway  for  seamless  supervision  of  hundreds  of  counters.If  Wi-Fi,  LTE  Cat-M1, 
Ethernet,  or  a  smart  gateway  is  used,  recorded  data  is  automatically  uploaded  to  the  Multi  Pulse 
Counter  management  website.  Naming  customization  can  be  made  on  the  website  to  make 
understanding  the  data  easy.  A  3.6V  Non-Rechargeable  battery  is  provided  with  the  device  to 
ensureaccurate operation for a limited period during a power outage.  

Summary of Contents for Multi Pulse Counter

Page 1: ...lti Pulse Counter 16 Port Smart Monitoring System 225 Arnold Road Lawrenceville GA 30044 Phone 800 886 3837 Email nemeter globalpowerproducts com Installation Operation Manual Version 1 10 October 202...

Page 2: ...ersion number Global Power Products Inc reserves the right to revise this publication and to make any modifications to its content at any time without obligation to notify any party person or entity o...

Page 3: ...mplied including any implied warranty of merchantability or fitness for a particular purpose GlobalPower Products shall not be liable for any indirect special or consequential damages arising from any...

Page 4: ...Pulse Counter Input Specifications 6 Power Specifications 7 Battery Specifications 7 Enclosure Specifications 7 Product Code Structure 8 Mounting Instructions 9 Setup Instructions 9 Operation 10 Mult...

Page 5: ...ure 5 Adjusting the contrast by rotating the adjustment screw 11 Figure 6 Show the login page of the Multi Pulse Counter data server 12 Figure 7 Multi Pulse Counter data webpage showing the number of...

Page 6: ...DC Power Supply 1 Multi Pulse Management Website Login informationand manual 1 Table 1 Contents inside the shipped package Principle of Operation The Multi PulseCounter is an electronic pulse counter...

Page 7: ...xplosion and burnhazards For more information on the battery backup and operation kindly visit Battery Specifications on Page 3 Pulse Counter Input Specifications Input Voltage 0 24 VDC Maximum Count...

Page 8: ...ile running on battery we estimate the device can countto 1 million pulses before it runs out of charge The actual battery backup time may vary depending on the input pulse frequency and the remaining...

Page 9: ...l be labeled as MPC DD WF Along with the model number each specific Multi Pulse Counter has a unique serial number used for identification purposes The configuration dry wet of each input terminal blo...

Page 10: ...negative wire to the position marked Black for each terminal block In case of a dry passive pulse from a mechanical switch the wires can be connected either way to each terminal block In case of a dry...

Page 11: ...e displayed to indicate how much charge is left on the battery If a communication module has been installed on the device a record of the counts will be uploaded to the Multi Pulse Counter management...

Page 12: ...lat screwdriveras shown in figure 4 Figure 5 Adjusting the contrast by rotating the adjustment screw MultiPulse Counter Management Website Instructions The data uploaded by the Multi Pulse Counter can...

Page 13: ...n the Click Here to Download icon The data can also be viewed in a graphical format by clicking on the Graph button on the left side of the webpage You can select any input from the drop down menu alo...

Page 14: ...the name of each input so that tracking each device is simple Figure 9 Multi Pulse Counter webpage with the available customizable options for the users Finally all the groups in this account will be...

Page 15: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not i...

Page 16: ...tenna s used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co located or operating in conjunction with any other antenna or...

Reviews: