31
Global Manufacturing, Inc
®
800.551.3569
TOLL FREE USA & CANADA
1801 East 22nd Street
501.374.7416
TEL
501.376.7147
FAX
Little Rock, AR 72206 USA
w w w. G l o b a l M a n u f a c t u r i n g . c o m
Air Blaster Performance Data for GWE Models
Air Blaster
Model
Air
Pressure
psi
70
80
90
100
bar
4.8
5.5
6.2
6.9
4" Discharge
GWE4-12-28
Tank Volume is
1.7
ft³
(49 l)
Free Air Volume
ft³
9.8
11.0
12.0
13.2
liters
277
311
340
374
Fill Time
sec
15
15
15
15
Shot Time
sec
.08
.08
.08
.08
Force
lbf
877
1021
1200
1300
kN
3.93
4.58
5.38
5.83
Efficiency
lb/ft³
90
93
100
99
4" Discharge
GWE4-16-34
Tank Volume is
3.5
ft³
(99 l)
Free Air Volume
ft³
20.0
22.4
24.8
27.0
liters
566
634
702
765
Fill Time
sec
25
35
35
35
Shot Time
sec
.13
.15
.15
.15
Force
lbf
976
1185
1342
1467
kN
4.34
5.31
6.02
6.58
Efficiency
lb/ft³
50
53
54
54
4" Discharge
GWE4-20-30
Tank Volume is
5.0
ft³
(142 l)
Free Air Volume
ft³
28.8
32.2
35.6
39.0
liters
815
912
1008
1104
Fill Time
sec
35
40
40
40
Shot Time
sec
.18
.20
.21
.22
Force
lbf
1075
1350
1485
1635
kN
4.82
6.05
6.66
7.33
Efficiency
lb/ft³
37
42
42
42
6" Discharge
GWE6-24-48
Tank Volume is
10.6
ft³
(299 l)
Free Air Volume
ft³
61.0
68.3
75.5
82.7
liters
1727
1934
2138
2342
Fill Time
sec
90
90
90
105
Shot Time
sec
.20
.21
.22
.23
Force
lbf
2681
2812
3230
3333
kN
12.02
12.60
14.48
14.94
Efficiency
lb/ft³
44
41
43
40
6" Discharge
GWE6-30-60
Tank Volume is
22.8
ft³
(645 l)
Free Air Volume
ft³
131.3
147.0
162.4
178.0
liters
3718
4162
4599
5040
Fill Time
sec
210
210
210
210
Shot Time
sec
.38
.40
.42
.44
Force
lbf
3190
3345
3840
3965
kN
14.30
14.99
17.21
17.77
Efficiency
lb/ft³
24
23
24
22
FILL TIME = Time to fill tank /- 2 psi of regulated pressure using 3/8" x 10’ fill line. Fill time may vary depending
on fill line size and length, compressor characteristics, and environmental conditions.
FORCE measurements were made using an 8" diameter, 1" thick piston, located 4" from the Air Blaster discharge mount
flange, to transfer the blast impulse to a dynamic sensor. A 1" solenoid valve, without muffler, mounted directly to the air
inlet port was used to fire the GWE4 and GWE6 model Air Blasters.
FILL TIME, SHOT TIME, & FORCE for the GWE6-30-60 were not measured. The data presented is an estimation of perfor-
mance for this model. The force output is too powerful for the dynamic sensor.
Appendix F - Performance Data