OPEN Command allows only Open.
CLOSE
Command allows only Close.
IR Photocell- Grounding IR, senses obstruction and a closing gate stop and
reverses.
2S
–
Manual Switch for Dual gate operation. Grounding activates,
alternatively open- close.
Flash-
Intermittent closed contacts of 24V.
Lock
– 24V Electric Lock. Activates only in START of opening.
DIP SWITCH: 4 terminals
ON
OFF
1
Motor works with 80% Power
Motor works with 100% power
2
Auto Close Enable
Auto Close Disable
3
Auto Close delay time
Auto close delay time
4
Delayed closing for Motor1
– 3 sec
Delayed closing for Motor1-1.5 sec
RF Remote Control:
Two Channels( buttons) provided.
A
- Open- Close- Open Dual Gate.
B
- Open
– Close- Open Single gate.
Learning Remotes
.:
Press LEARN button on the Remote Receiver Board once. Its LED lit.
Keep pressing a button on the RF Remote.
Receiver LED blinks 3 Times and is learnt. Repeat for other remotes.
Erasing the RF Remote:
Press LEARN Button on the RF Receiver 8 times. Then LED blinks several times.
Now the RF Remote is erased.
Battery in the RF Remote has an estimated life of 12 months. Replace both, if
necessary.(CR2016)
Motor Arm Fixing for Outward opening Gates: