11
CEILING INSTALLATION
Ceiling installation of the DSH heater MUST be performed using the ceiling bracket accessory DSHCMB (sold
seperately). This ceiling bracket accessory allow for installation of one or two DSH infrared heaters on the ceiling. This
bracket can be installed indoors or outdoors.
Cables can be passed within the center of the bracket. The telescopic pole can be adjusted for four different heights,
ranging from 35.5 cm (14") to 61 cm (24").
The DSHCMB contains the following components:
Quantity
A
Support Bracket
1
B
Telescoping Bracket
1
C
M6 x 55 Philips bolt, spring washer, and wing nut
4
D
Hex Wrench
1
1. Set the height of the ceiling bracket by inseriting the
telescoping pole into the support bracket and installing
the hardware at the desired height. (Figure 11)
!
NOTE:
The minimum distance between the bottom
end of the pole to the ceiling is 35.5 cm (14") and
the maximum distance is 61 cm (24"). See the
Site Selection
section to ensure that all minimum
clearances have been met.
2. Install the heater to the fixing bracket by setting the
adjustable angle mounting brackets to the desired angle
and fasten the brackets with an adjustable wrench.
(Figure 10)
3. Secure the heater and fixing bracket to the ceiling-
mounting bracket using the hardware pre-installed on
the ceiling-mounting bracket. The hardware should
be threaded through the holes labeled D in Figure 9.
(Figure 12, Figure 13)
4. Secure the bracket to the ceiling using hardware
suitable for your application (not included).
!
NOTE:
Depending on material and design of ceiling
structural elements, the heater must be secured with the
correct fasteners. The weight of each DSH heater is 3.75
kg. The installation structure and hardware must be able
to hold 5 times the weight of the heater(s).
Figure 11
Figure 12
Figure 13
One Heater Installation
Two Heater Installation
Installation