DESIGN

DESIGN

DESCRIPTION

DESCRIPTION

g) Less controls – The thermal store is open 

vented and therefore does not require 

additional safety devices such as temperature 

and pressure relief valves or an inlet control 

group and expansion vessels. 

h) Building Regulation – The thermal store, 

being open vented, does not require 

Building control to be notified to comply 

with section G3 of the building regulations, 

unlike an unvented cylinder which does.

i)  Annual inspection – The running costs of this 

cylinder are greatly reduced by not being 

required to have an annual safety inspection 

where as an unvented cylinder does.

The Torrent provides high performance mains 

pressure hot water without the additional costs 

incurred with an unvented cylinder.

The Torrent GreenHeat is available in the 

following basic variants:-

Torrent GreenHeat OV

The Torrent GreenHeat OV utilises an open 

vented boiler and / or direct electric immersion 

heaters as its primary energy source. It is 

available with tappings for a woodburning 

or solid fuel boiler, but if any of the standard 

tapping are not required, they can be removed 

at the time of order.

One of the benefits of the open vented boiler 

configuration is that the whole output of the 

boiler is available to the thermal store, unlike 

the indirect Sealed Primary (SP) version where 

the output from the boiler is limited by the heat 

exchanger. This will provide an improvement in 

the operational efficiency of the boiler, reducing 

the primary energy usage and running costs.

The Torrent GreenHeat OV provides high-

performance mains pressure hot water. The 

heat energy provided from the primary heat 

source and / or solid fuel input is circulated 

from the store to the central heating circuit, 

allowing rapid heat-up of a radiator system.

In situations where no gas or solid fuel source 

is available the Torrent GreenHeat OV can be 

used exclusively from the two 3kW electric 

immersion elements which will provide both 

hot water and auxiliary heating for the property. 

The obvious application is apartments where 

no gas main is available but this could also be 

appropriate where electricity is available from a 

renewable or low carbon source. 

If connected to the standard grid then the 

thermal store is the perfect solution to maximise 

usage of an off peak tariff where arrangements 

Gledhill developed the principal of domestic thermal stores starting in 1982 and 

they have been manufacturing them since then.

Their importance to plumbing systems is described below.

a)  Why use a thermal store - Alternative energy fuel sources are typically low grade, 

inherently unpredictable and are often available in plentiful supply but not when 

the heat energy is needed! A thermal store provides the means to harness the 

energy when it is available for later conversion into both hot water AND heating. 

  Being open vented, they provide a simple and inherently safe way to produce high-

performance mains pressure hot water. So the householder can enjoy the comfort 

and luxury of a mains pressure system produced from alternative energy sources. 

  The alternative energy feeds into the thermal store which is also the water that 

circulates around the heating system. This means that the energy available from 

solar panels or a wood burning stove, for example, can be used to provide energy 

into the heating circuit to decrease the use of fossil fuel based boilers, and hence 

reduce household running costs. 

  It is very problematic and inherently unsafe to connect wood burning stoves or 

other uncontrolled heat sources to an unvented cylinder, and not easily possible 

to combine alternative energy heat sources to provide energy to the heating 

circuit, hence the unique advantages of a thermal store.

b) The heart of an alternative energy system - The Torrent GreenHeat is the ideal 

product to use as the heart of an alternative energy system as it will take 

energy input not only from a conventional boiler but also from a wide variety of 

alternative energy sources, including but not limited to: 

 

•   solar  panels 

  •   wood burning stoves and other uncontrolled heat sources

  •   ground or air source heat pumps

  •   electricity from renewable or low carbon sources

  If the system is configured appropriately the heat from the alternative energy 

source will be available for both hot water AND heating. This is only possible with 

a thermal store such as the Torrent and is not possible with an unvented cylinder 

where you will only get an alternative energy contribution to the hot water.

c)  In-built upgrade potential - You are able to specify from the required tappings, 

with any future requirements, for example, a wood burning stove or solar panels 

can be added as an upgrade to the property at a later stage and the hot water 

cylinder will be ready to work with it.

d)  Neutral Point - The Torrent GreenHeat becomes the neutral point in any open vented 

system because the open vent and cold feed pipes are connected to it. The benefit 

of this is that another device to enable different systems to be joined together at a 

neutral point is not required, which would be required in other systems. In multiple 

fuel systems, the Torrent acts as a low loss header.

e)  Apartments – The Torrent open vented thermal store does not need a discharge pipe 

from a pressure and temperature relief valve, unlike an unvented cylinder which does. 

This combined with the fact that discharges are not permitted into PVCu soil stacks 

makes the installation of un-vented stores in apartments difficult and expensive.

f)  Legionella Risk – Alternative energy supplies cannot be relied upon to raise the 

temperature of the stored water above 60 degrees every time they operate. This 

is not a problem with a thermal store because the store water is not the water that 

comes out of the tap. The water that comes out the hot tap is mains cold water 

run through a plate heat exchanger on the outside of the thermal store. This water 

heats very quickly and the volume of stagnent water in the heat exchanger is very 

small so there is virtually no legionella risk.

should be made to power the lower immersion element in order to minimise the running 

costs. It is important to note that the design heat loss, of the rooms to be heated, must 

be less than the lowest immersion power. If the design heat loss is greater than this, the 

heating will need to be supplemented by another heat source.

The Torrent GreenHeat OV is designed to be heated directly (i.e. without internal heat 

exchangers) by one or more of the following heat sources;

•  Electric immersion heaters e.g. to utilise off peak electricity

•  A remote gas or oil boiler

•  A solid fuel boiler or stove 

Torrent GreenHeat SP

The Torrent GreenHeat SP utilises a sealed system boiler as its primary energy source. 

It is available with tappings for a woodburning or solid fuel boiler, but if any of the 

standard tapping are not required, they can be removed at the time of order. The 

Torrent GreenHeat SP provides high-performance mains pressure hot water.

Where a sealed primary coil is used,  the thermal store is a hot water only thermal store. 

If too much heat is taken out of store,  then hot water performance will be limited. The 

hot water priority should be protected by use of an appropriate thermostat. The central 

heating circuit is normally supplied directly from the boiler although an auxiliary 

heating circuit can be connected from the store in which case the solid fuel source 

will provide energy to the auxiliary heating circuit. Obviously, the energy output that 

can be provided by the auxiliary heating circuit will be limited to the energy input 

from the solid fuel appliance.

This sealed primary (SP) model permits the use of a smaller feed and expansion tank 

because the main central heating circuit does not need to be catered for. This can 

make positioning the F&E tank more straightforward.

An immersion element is provided and it is normally envisaged that this will be used as an 

emergency electric back-up for hot water and to provide emergency energy to the auxiliary 

heating circuit. However, if a low carbon or renewable electricity source is available then 

this could be connected to the immersion element to provide heat input to the thermal 

store, decreasing the use of the fossil fuel boiler and hence reducing running costs.

The Torrent GreenHeat SP is designed to be heated by one or more of the following 

heat sources;

•  Directly by an electric immersion heater as a backup heat source only

•  Indirectly (i.e. via a heat exchanger) by a remote gas or oil boiler

•  Directly by a solid fuel boiler or stove

Torrent GreenHeat SOL

The Torrent GreenHeat SOL utilises either a sealed system boiler and / or an open 

vented boiler as its primary energy source. It also has a high-efficiency solar coil to 

allow the homeowner to benefit from a wide variety of alternative energy inputs. 

It is available with tappings for a woodburning or solid fuel boiler, but if any of the 

standard tapping are not required, they can be removed at the time of order.

The Torrent GreenHeat SOL provides high-performance mains pressure hot water.The 

central heating circuit can be supplied directly from a sealed system boiler although 

an auxiliary heating circuit can be connected from the store in which case both the 

solar and solid fuel energy will also provide an input to the auxiliary heating circuit. 

Alternatively, an open vented boiler can be used to directly heat the store so that the 

energy will be available for both hot water and auxiliary central heating circuit.

The cylinder comes with two return connections for solid fuel and woodburning 

stoves to enable the homeowner to have an aga running 24 hours a day but still 

retaining the dedicated solar volume.

An immersion element is provided and it is normally envisaged that this will be 

used as an emergency electric back-up for 

hot water and to provide emergency energy 

to the auxiliary heating circuit. However, if a 

low carbon or renewable electricity source is 

available then this could be connected to the 

immersion element to provide heat input to the 

thermal store, decreasing the use of the fossil 

fuel boiler and hence reducing running costs.

The Torrent GreenHeat SOL is designed to be 

heated by one or more of the following heat 

sources;

•  Directly by an electric immersion heater as 

a backup heat source only

•  Either indirectly or directly by a remote gas 

or oil boiler

•  Directly by a solid fuel boiler or stove

•  Indirectly by solar thermal system

Torrent GreenHeat HP Models

The Torrent GreenHeat HP and HP SOL are 

directly heated, open vented thermal stores 

designed for use with an air source or a ground 

source heat pump. It is available with tappings 

for a woodburning or solid fuel boiler, but if any 

of the standard tapping are not required, they 

can be removed at the time of order.

Although the thermal store is open vented, 

the mains pressure hot water is heated 

instantaneously via the plate heat exchanger.

The Torrent GreenHeat HP range of primary 

thermal stores are only suitable for open 

vented heating systems but they provide mains 

pressure hot water without the requirements of 

a pressure and temperature relief valve. 

The suggested model sizes are based on typical 
hot water usage and the store charged to about 
75°C. If the store charge temperature is going 
to be lower, then a larger model should be 
considered. This is especially important where 
the heat pump alone is unable to charge the 
store to 75°C as is likely to be the case with a 
heat pump. If the immersion element is used 
to raise the temperature of the store, then 
a suitable control system should be used 
to ensure the immersion element does not 
operate until the heat pump has raised the store 
to the maximum temperature, or the overall 
efficiency of the system will be reduced.

The Torrent GreenHeat HP and HP SOL is 

designed to be heated by one or more of the 

following heat sources;

•  Directly by a ground source or air source heat 

pump

•  Directly by an electric immersion heater as 

a backup heat source only

•  Directly by a solid fuel boiler or stove

•  Indirectly by solar thermal system

Summary of Contents for Torrent GreenHeat HP TGH170

Page 1: ...al Torrent GreenHeat OV TGH140 TGH350 Torrent GreenHeat SP TGH140 TGH350 Torrent GreenHeat SOL TGH210 TGH450 Torrent GreenHeat HP TGH170 TGH450 Torrent GreenHeat HPSOL TGH210 TGH450 Torrent GreenHeat Open vented thermal store providing heating and mains pressure hot water ...

Page 2: ...n updated set of Instructions will be produced and supplied with new appliances and will be made available for other appliances on request Benchmark places responsibilities on both manufacturers and installers The purpose is to ensure that customers are provided with the correct equipment for their needs that it is installed commissioned and serviced in accordance with the manufacturers instructio...

Page 3: ...he volume of stagnent water in the heat exchanger is very small so there is virtually no legionella risk shouldbemadetopowerthelowerimmersionelementinordertominimisetherunning costs It is important to note that the design heat loss of the rooms to be heated must be less than the lowest immersion power If the design heat loss is greater than this the heating will need to be supplemented by another ...

Page 4: ... 155 n a 95 95 n a n a n a 195 1040 1115 1 38 n a 134 1 81 n a 35 TGH170 SP 44 207 170 1449 535 720 n a 1270 1270 690 n a 650 570 322 470 145 n a 135 90 n a 385 n a 95 95 n a n a n a 195 1270 1345 1 38 n a 163 2 03 n a 35 TGH210 SP 47 248 210 1414 585 680 n a 1235 1235 685 n a 645 555 412 455 145 n a 125 90 n a 345 n a 95 95 n a n a n a 195 1235 1310 1 84 n a 201 2 30 n a 35 TGH250 SP 49 288 250 1...

Page 5: ...GH350 HP 43 282 350 1874 630 1140 n a 1690 1690 900 355 215 300 430 515 615 n a 130 95 805 n a 100 100 385 100 615 385 100 n a n a 200 1690 1770 n a 339 3 14 n a 15 TGH450 HP 53 388 450 1764 730 935 n a 1490 1490 880 390 310 395 510 595 630 n a 270 40 600 n a 270 270 420 270 630 420 270 n a n a 370 1490 1785 n a 431 3 67 n a 15 Torrent GreenHeat HP SOL TGH210 HPSOL 49 250 210 1414 580 680 920 1235...

Page 6: ...Solarcoilflow 22mmcomp 450 28mmcomp 19 Cold feed 15mm comp 20 Solar sensor 21 Solarcoilreturn 22mmcomp 450 28mmcomp 22 Plate heat exchanger return 22mm 23 Solid fuel return 2 28mm comp 24 Drain 1 2 female Component kit supplied attached A Thermostat B Immersion heater Optional extra components A Header tank B Ball valve C Float D Overheat thermostat E Solid fuel tappings F Sealed primary boiler co...

Page 7: ...imary circuit pressures e g it is not fitted with a non adjustable low system pressure switch The heat pumps normally operate at lower temperature difference 5 10 C betweenflowandreturnthanthatforagasboilers 10 20 C resultinginhigherflow rates in the heat pump primary circuit Therefore it is important that the primary pipeworkconnectingtheheatpumptothethermalstoreandthecirculatingpump are sized to...

Page 8: ...ferred range is between 2 and 3 0 bar If the incoming static mains pressure exceeds 5 0 bar at any point in the 24 hour cycle then a pressure limiting valve set at 3 0 bar should be fitted downstream of the stop tap where the cold supply enters the dwelling If a water meter is fitted in the service pipe it should have nominal rating to match the anticipated maximum simultaneous hot and coldwater d...

Page 9: ...ing scale protection should be complied with These requirements state that where the mains water hardness exceeds 200ppm provision should be made to treat the feed water to the water heaters and the hot INSTALLATION INSTALLATION INSTALLATION INSTALLATION Thermostat Immersion Heater Wiring E L N water circuit of combination boilers to reduce the rate of accumulation of scale To comply with this req...

Page 10: ...ge In this case no bypass valve is required unless TRV s are used on all radiators If the flow and return pipes between the boiler and the Torrent OV thermal store are dipped as illustrated in the schematic shown opposite then the boiler selected must be suitable for a sealed heating system i e it must be fitted with an overheat thermostat Automatic air vents should be fitted at appropriate places...

Page 11: ...se refer to page 20 for further information Where a sealed primary coil is used the thermal store is a hot water only thermal store If too much heat is taken out of store then hot water performancewillbelimited Thehotwaterpriority should be protected by use of an appropriate thermostat Heating can be taken from the SP thermal store to provide auxilliary heating to towel radiators which are low out...

Page 12: ...ch does not require a minimum pressure in the primarycircuitforoperation Thespaceheating can be supplied directly from the heat pump circuit or from the thermal store The selection between the two options will depend upon the operating characteristics of the heat pump type of heating system and control strategy For general guidance If the heat pump requires a buffer for operation for example to re...

Page 13: ...eated The overheat thermostat should be set at a temperature which operates before or at 85 C Please see page 23 for further information A solid fuel boiler can also be connected to the Torrent GreenHeat SOL please refer to page 20 for further information Solar heating circuit The Torrent SOL is an advanced thermal store and has been designed to incorporate existing boiler and central heating cont...

Page 14: ... Typical components not supplied but available to purchase from Gledhill Spares Ltd 1 x Honeywell V4043B1265 28mm compression normally open 2 port valve 1 x Honeywell V4043H1106 28mm compression normally closed 2 port valve 1 x Honeywell L641B1012 High limit pipe thermostat 1 x XC010 control thermostat When the boiler is lit the water temperature raises When the temperature is above INSTALLATION I...

Page 15: ...ovided by a temperature sensor S3 which is wired directly to the solar controller same as sensors S1 and S2 In this case the mechanical overheat thermostat S3 shown in this diagram is not required and the solar pump is wired straight to the solar controller Temperature range 50 95 o C Boiler hold off pipe thermostat Type LL641B1012 Thermal store temperature max 85 C more typically 75 77 C Installe...

Page 16: ...tection is provided by a temperature sensor S3 which is wired directly to the solar controller same as sensors S1 and S2 In this case the mechanical overheat thermostat S3 shown in this diagram is not required and the solar pump is wired straight to the solar controller Normally Closed 2 Port Valve Normally Open 2 Port Valve E E L N N SL PL ML Control Stat 2 1 C 2 Pipe Thermostat 1 1 C 2 on off on...

Page 17: ...d as shown in figure 4 4 to protect the store from over heating by stopping the solar Pump at pre set temperature limit S1 S2 S3 E N R1 N R1 N L 1 2 3 4 5 6 7 8 12 13 14 15 16 17 18 19 20 Solar controller N L E 1 2 3 Normally Closed 2 Port Valve Normally Open 2 Port Valve E E L N N SL PL ML Control Stat 2 1 C 2 Pipe Thermostat 1 1 C 2 on off on off Temperature range 50 95 o C Boiler hold off pipe ...

Page 18: ...ematic wiring diagram for the Torrent GreenHeat HP and Torrent GreenHeat HP solar with space heating supplied directly from the heat pump circuit Typical schematic wiring diagram for the Torrent GreenHeat HP and Torrent GreenHeat HP solar with space heating supplied from thermal store ...

Page 19: ...eater so that the store can be heated to a temperature above the heat pump delivery temperature to increase the hot water performance of the unit if necessary Because the TorrentHP is a primary thermal store it is not necessary to heat the store above 60 C for hygienic protection against growth of legionella This is because the domestic hot water is heated instantaneously via a heat exchanger and ...

Page 20: ...the inside back pages of this document Electrician Installer Please note that water at the hot tap does not indicate that the Torrentisfull Checkthatthereiswaterinthefeedandexpansiontankbeforeswitching on the immersion heaters Dry firing the elements will cause premature failure which is not covered by our warranty Non Electric Torrent Models Opentheincomingstopvalveandfillthedomestichotwatersyste...

Page 21: ...ap Is the circuit correctly sized Fit an air vent Is the temp rise now satisfactory Investigate for blockage Is air trapped in the primary circuit Annual Servicing No annual servicing of the Torrent GreenHeat is necessary However if required a hot water performance test can be carried out to prove the appliance is working satisfactorily and within its specification If it is decided to carry out th...

Page 22: ... keeps sticking intermittently Hot cold crossed at appliance DHW temperature exceeds and remains well above 60 C when the flow rate is low DHW printed circuit control board and or temperature sensor is are faulty Thermostats set to high see pages 23 and 38 for details Store not heating Other heat sources failed Incorrect plumbing arrangement No power supplies fuses are blown Overheat stat has trip...

Page 23: ... constant flow rates by automatically compensating for supply pressure changes between 1 bar 10 bars To facilitate installation into the wide range of plumbing equipment which is encountered in the U K Four Fixing Options are available Options For Showers 1 MXF DW Range For fitting behind Fixed Shower Heads or onto Flexible Hoses for Handshowers preferably onto the inlet end when lightweight hoses...

Page 24: ... Before lifting ensure you have a good hold e Taking the lead for team lifts As more than one person is required for these products ensure that one person is taking the lead This may be you so ensure that each person that is helping is made aware of the weight and of the items listed within this assessment Make sure you and any others helping know the route you intend to take that it is clear of a...

Page 25: ... development and may introduce product modifications from time to time Gledhill Building Products Ltd AMD DECEMBER 2013 CONDITIONS OF SALE GUARANTEE TERMS 1 Gledhill Building Products Ltd We or Gledhills only do business upon the Conditions which appear below and no other Unless we so agree in writing these Conditions shall apply in full to any supply of goods by us to the exclusion of any Conditi...

Page 26: ...mpany name Telephone No Comments Signature SERVICE 05 Date Engineer name Company name Telephone No Comments Signature SERVICE 07 Date Engineer name Company name Telephone No Comments Signature SERVICE 09 Date Engineer name Company name Telephone No Comments Signature SERVICE 02 Date Engineer name Company name Telephone No Comments Signature SERVICE 04 Date Engineer name Company name Telephone No C...

Page 27: ... services including Low cost annual repair and maintenance contracts direct from Gledhill Annual servicing and safety checks Expert response to out of warranty breakdowns at fixed charges Please call 08445 679898 or visit www gledhill net for further details Only the best is acceptable FM 02057 To protect our environment we use copper a totally recyclable metal which never becomes waste Gledhill B...