GLAZING VISION Xvent Operation And Maintenance Manual Download Page 7

 

405-OM-UK-001 v1.0 

 09 Jul 2020 

 

Need assistance? +44 (0)1379 658300 [email protected] 

Page 7 of 18 

Controls and Operation 

 
Various options are available at time of order. If specific data is required for your product, please refer to your order confirmation or 
contact your supplier for assistance. 
 

Control Switch 

The standard operation of the unit is via the supplied wall mounted control switch and can be operated using two different methods 
as explained below: 
 

 

Figure 1 

 Wall mounted control switch 

 

‘One touch’ operation

 

 Press and release the control switch once in either the up or down direction - the product will open or close 

fully. Partially open positions can be achieved by pressing the control switch again at any point during the open or close cycle. 
 
Conventional 

‘hold’ operation

 

 Press and hold the control switch until the product has reached the desired position, releasing the 

switch stops the product in that position. Note that the product will stop automatically when it becomes either fully open or closed.  
 

Status Light 

The status light will illuminate green if the product is functioning normally. If the status light displays another colour, please refer to 
the troubleshooting section of this document. 
 

Remote Control (Optional) 

The remote control unit functions in the same way as the wall mounted control switch but allows you to open and close your product 
from a short range. It has 3 control buttons, open, stop and close - the stop button can be used for partial opening. 
 
The remote control is powered by 2 x AAA batteries. In order to preserve the battery, the remote control will switch itself off after a 
brief period of inactivity. It will switch itself on when any of the buttons on the remote control are pressed. To replace the batteries, 
remove the small hex screws found on the rear of the remote to allow access inside. Note the polarity when inserting the new 
batteries. 
 

 

 Figure 2 

 Remote control 

 
 
 
 
 
 
 

Status light 

Status light 

Summary of Contents for Xvent

Page 1: ...405 OM UK 001 v1 0 09 Jul 2020 www glazingvision co uk 44 0 1379 658300 info glazingvision co uk Xvent...

Page 2: ...tion Page Introduction 3 Safety Information 4 Basic Operation 6 Controls and Operation 7 Manual Override 9 Troubleshooting 12 Glass Specification and Breakage Instructions 13 Routine Testing and Maint...

Page 3: ...access A variety of optional extras including a rain sensor thermostat remote control and Building Management System connectivity are available This product is robust and long lasting boasting excelle...

Page 4: ...amage to the product and its mechanisms It should not be relied upon to prevent injuries Let our experts carry out your routine maintenance with a maintenance contract 44 0 1379 658300 info glazingvis...

Page 5: ...t may open close unexpectedly e g due to the rain sensor activating and cause injury Do not pull on the cables where they exit the product Doing so may loosen connections result in damage to the produ...

Page 6: ...arm activation must be by manual operation using the wall mounted control switch this is to allow somebody to walk around the building duringa fire drill and check each that each individual rooflight...

Page 7: ...ion releasing the switch stops the product in that position Note that the product will stop automatically when it becomes either fully open or closed Status Light The status light will illuminate gree...

Page 8: ...mote control together and immediately release them The status light on the remote control should turn red for a few seconds and then turn off If it turns green or amber try pressing the three buttons...

Page 9: ...support system in place unscrew the bolts using a pin torx driver This will disengage the mechanisms from the lid Next unscrew the mechanisms from the base frame and allowing them to be removed from...

Page 10: ...e legs from slipping when working take care not to knock the support legs out of place Figure 6 Support legs Support Option 3 Chain or Strap This option can be used when there is not enough space for...

Page 11: ...d by Glazing Vision personnel or Approved Installers If the manual override has been used the product requires re initialising As the Xvent is a safety critical product this will need to be done by a...

Page 12: ...n close button will clear this condition Continuous red after power on fault recovery Indicates that the product requires initialisation synchronisation Pressing close on the wall mounted switch will...

Page 13: ...eaning open the product and isolate the power supply then clean the rain sensor The thermostat if specified is reacting to a change in temperature and triggering the product to close Check that the th...

Page 14: ...ance requirements must be completed and logged on the sheets at the back of this manual Glazing Vision can offer a service maintenance contract please contact us for further details Suitably qualified...

Page 15: ...nsor if present Disposal at End of Life Glazing Vision design products with ease of recyclability at end of life in mind Many of the main components used are widely recyclable and we encourage you to...

Page 16: ...fied to BS EN 12101 2 2003 and is fully CE marked Visit our website or contact your technical sales advisor for up to date certification documentation The following label will be affixed to the exteri...

Page 17: ...ents yes no Battery Replacement yes no Cleaning Requirements yes no Annual Requirements yes no Battery Replacement yes no Cleaning Requirements yes no Annual Requirements yes no Battery Replacement ye...

Page 18: ...cement yes no Cleaning Requirements yes no Annual Requirements yes no Battery Replacement yes no Cleaning Requirements yes no Annual Requirements yes no Battery Replacement yes no Cleaning Requirement...

Reviews: