GLAZING VISION Xvent Operation And Maintenance Manual Download Page 5

 

405-OM-UK-001 v1.0 

 09 Jul 2020 

 

Need assistance? +44 (0)1379 658300 [email protected] 

Page 5 of 18 

 

Do not place anything on, or cause obstruction to, the moving sections of the product as this may cause damage to the 
mechanisms/product and/or prevent the unit from opening/closing. 

 

Do not allow unauthorised persons (e.g. children) to operate the product as this may lead to personal injury or damage to 
the product. Do not leave children or pets unsupervised near the product 

 it may open/close unexpectedly (e.g. due to the 

rain sensor activating) and cause injury. 

 

Do not pull on the cables where they exit the product. Doing so may loosen connections, result in damage to the product 
and/or create the need for a repair visit. 

 

Do not leave the product open in the rain, this could damage the control board and/or mechanisms. If required, a rain 
sensor can be specified at the time of order. 

 

Should any cables or electrical components break or become damaged, have them repaired or replaced immediately. 
Deteriorated insulation of electrical parts or overloading may cause an electric shock or fire. 

 
For more information or assistance please contact Glazing Vision. 

 

 

Summary of Contents for Xvent

Page 1: ...405 OM UK 001 v1 0 09 Jul 2020 www glazingvision co uk 44 0 1379 658300 info glazingvision co uk Xvent...

Page 2: ...tion Page Introduction 3 Safety Information 4 Basic Operation 6 Controls and Operation 7 Manual Override 9 Troubleshooting 12 Glass Specification and Breakage Instructions 13 Routine Testing and Maint...

Page 3: ...access A variety of optional extras including a rain sensor thermostat remote control and Building Management System connectivity are available This product is robust and long lasting boasting excelle...

Page 4: ...amage to the product and its mechanisms It should not be relied upon to prevent injuries Let our experts carry out your routine maintenance with a maintenance contract 44 0 1379 658300 info glazingvis...

Page 5: ...t may open close unexpectedly e g due to the rain sensor activating and cause injury Do not pull on the cables where they exit the product Doing so may loosen connections result in damage to the produ...

Page 6: ...arm activation must be by manual operation using the wall mounted control switch this is to allow somebody to walk around the building duringa fire drill and check each that each individual rooflight...

Page 7: ...ion releasing the switch stops the product in that position Note that the product will stop automatically when it becomes either fully open or closed Status Light The status light will illuminate gree...

Page 8: ...mote control together and immediately release them The status light on the remote control should turn red for a few seconds and then turn off If it turns green or amber try pressing the three buttons...

Page 9: ...support system in place unscrew the bolts using a pin torx driver This will disengage the mechanisms from the lid Next unscrew the mechanisms from the base frame and allowing them to be removed from...

Page 10: ...e legs from slipping when working take care not to knock the support legs out of place Figure 6 Support legs Support Option 3 Chain or Strap This option can be used when there is not enough space for...

Page 11: ...d by Glazing Vision personnel or Approved Installers If the manual override has been used the product requires re initialising As the Xvent is a safety critical product this will need to be done by a...

Page 12: ...n close button will clear this condition Continuous red after power on fault recovery Indicates that the product requires initialisation synchronisation Pressing close on the wall mounted switch will...

Page 13: ...eaning open the product and isolate the power supply then clean the rain sensor The thermostat if specified is reacting to a change in temperature and triggering the product to close Check that the th...

Page 14: ...ance requirements must be completed and logged on the sheets at the back of this manual Glazing Vision can offer a service maintenance contract please contact us for further details Suitably qualified...

Page 15: ...nsor if present Disposal at End of Life Glazing Vision design products with ease of recyclability at end of life in mind Many of the main components used are widely recyclable and we encourage you to...

Page 16: ...fied to BS EN 12101 2 2003 and is fully CE marked Visit our website or contact your technical sales advisor for up to date certification documentation The following label will be affixed to the exteri...

Page 17: ...ents yes no Battery Replacement yes no Cleaning Requirements yes no Annual Requirements yes no Battery Replacement yes no Cleaning Requirements yes no Annual Requirements yes no Battery Replacement ye...

Page 18: ...cement yes no Cleaning Requirements yes no Annual Requirements yes no Battery Replacement yes no Cleaning Requirements yes no Annual Requirements yes no Battery Replacement yes no Cleaning Requirement...

Reviews: