Keep Components A and B
Separate
CAUTION
To prevent cross-contamination of the equipment’s wet-
ted parts, never interchange component A (isocyanate)
and component B (resin) partrs. The gun is shipped with
the A side on the left. The fluid manifold, fluid hous
-
ing, side seal assembly, check valve cartridge, and mix
chamber are marked on the A side.
Foam Resins with 245 fa
Blowing Agents
New foam blowing agents will froth at temperatures above
90°F (33 °C) when not under pressure, especially if agitat-
ed. To reduce frothing, minimize preheating in a circulation
system.
Changing Materials
When changing materials, flush the equipment mul
-
•
tiple times to ensure it is thoroughly clean.
Always clean the fluid inlet strainers after flushing.
•
Check with your material manufacturer for chemical
•
compatibility.
Most materials use ISO on the A side, but some use
•
ISO on the B side.
Epoxies often have amines on the B (hardener) side.
•
Polyureas often have amines on the B (resin) side.
Warnings