- FIRST NAVIGATION LIGHTS
*
MODULE
IS NOT
RESPOND
ING
.
MODULE
S NOT RESPONDING
WILL BE
UNREGISTERED FROM
THE SYSTEM
* or some other module
If input module didn't respond during normal operation, but responds during
next equipment
turning
on process, equipment proceeds with normal
operation. In case of permanent input module malfunction, l
ights
can be
turn
on/off by switches on the modules.
- SOME MALFUNCTION OCCURS. AUTOMATIC RESET WAS DONE.
TURN ON APPROPRIATE LIGHTS!
This message appears after equipment turn on in case when turning on is
not result of normal turning on by POWER ON/OFF button, but as result of
automatic reset. Automatic reset occurs in case when supply is restored
during power failure signalization and in case of software execution
malfunction.
-
POWER SUPPLY IS SWITCHED TO SPARE (or MAIN) SUPPLY
-
INTERNAL 12VDC POWER SUPPLY IS MISSING
THE DEVICE WILL STOP OPERATING WHEN
INTERNAL BATTERY BECOMES DISCHARGED.
After acceptance,
POWER/SYSTEM FAILURE LED
remains activated.
12V DC is used to power some electronic circuits, but is also used to
continuously charge the battery, which serves for the supply of
power/system failure alarm. Thus, when there is no 12V
DC
, main unit runs
on battery, but only until it runs out.
-
ERROR
SERIAL COMMUNICATION INTERFACE, EXTERNAL
ACCEPT AND POWER CHANGE-OVER ALARM ARE
OUT OF ORDER.
After acceptance,
POWER/SYSTEM FAILURE LED
and output contact
remains activated.
This message is generated when problem in main units internal electronic
circuits operation is detected
.
As buzzer quitting by ACCEPT button maybe
will not be possible, buzzer will go off automatically after 10-15s.
29