Glacier GL-F-16M Operation Manual Download Page 9

8

5

Freeze

r C

omponents

Ø

The freezer controller has memory of the set point. The freezer will continue to follow the 

previous operations when restart the freezer after the power failure. The restart should be 
done after 5 minutes in case to damage the compressor.

Caution

Meiling will not be responsible for the safety ofthe stored articles.

4.7

 

Operatio

n a

fte

r p

owe

r f

ailure

File box

Touch screen 
controller

Door handle 
with lock

Wheels

Stand bar

USB port

Door

Power lock 
and Back-up 
Battery lock

(do not open it till power failure)

Air inlet and 
Condenser 
filter net

(Please clean it up regularly )

7

6. Displa

y p

ane

l f

unctio

n d

escription

(1)Control board introduction:

a. Both    -25     are temperature display windows. In normal operation, the average

temperature of the upper and lower chambers of the cabinet is displayed in °C; different

prompt characters can be displayed in the setting state (see below for details).
b. Door opening indicator : when the door is opened, the indicator light will be on. when the

door is opened more than 1 minute, the indicator lighting with buzzer alarm, display "door".
c. Fault indicator: The indicator is off when the product is operating normally; the indicator is

on when the product is operating abnormally.
d.“PRINT”: The system can retain 7 days of data for printing. Press the Print key to print the 

temperature for the set period of time.
e.

: In parameter setting mode, move to the previous parameter or decrease the value of

the parameter. For example, when setting the set temperature, reduce the set temperature.

When setting the parameter value, long press the key to quickly decrease the parameter.
f.          : In parameter setting mode, you can move to the next parameter or increase the value 

of the parameter. For example, when setting the set temperature, increase the set 

temperature value. When setting the parameter value, press and hold the up button for a long 

time and the parameter will increase rapidly. Under normal conditions, press and hold the key 

for 3 seconds to import the U disk for 12 months.
g.

is the button for set/mute, when there is no alarm state and the key is not unlocked,

press       , displaying ambient temperature for 5 seconds restores normal display; In the 

unlocked state, press          for 3 seconds, can enter the user menu. When buzzer alarm 

(including cabinet temperature over temperature alarm, door open alarm, sensor fault alarm, 

etc.), in the locked state, first time press           , Buzzer stops tweeting, 5 seconds after 

showing ambient temperature, resume normal display(The key mute is only to turn off the 

buzzer of this abnormal state alarm. If the fault is eliminated, the buzzer will continue to alarm 

when the next exception occurs), press             again, buzzer alarms, After the ambient 

temperature is displayed for 5 seconds, the cabinet temperature and alarm status are 

restored. When the press is under unlocked state,            can be used as a set button.

In the unlock state, in the parameter setting mode, press this key to display the value and the 

parameter name. If the pressed time is longer than 3 seconds, the setting is saved and the 

normal interface is returned.

a

b

d   printer(optional)

e

f

g

c

Summary of Contents for GL-F-16M

Page 1: ...www aegisfridge com OPERATION MANUAL Applicable product model GL F 16M ...

Page 2: ... 4 4 Standing 4 5 Power on for the First Time 5 Components and Overview 6 Display Panel Function Description 7 Defrost Unused Maintenance 7 1 Defrost 7 2 Unused and Maintenance 7 3 Disposal 8 After sale Service 9 Specifications 10 Performance 10 1 Main Technical Parameter 10 2 Packing List 10 3 Electrical Diagram 1 2 4 4 4 4 5 5 6 10 10 12 13 15 15 15 15 5 7 10 11 ...

Page 3: ...carefully the cautions and safety issues In order to make the device work properly please follow the correct installation method Medical freezer ultra low temperature freezer combined refrigerator and freezer can only be operated by trained and authorized personnel Maintenance of the equipment can only be carried out by agents authorized by Glacier If the operator encounters a situation not mentio...

Page 4: ...onnel may cause electric shock or fire Be sure to install the unit on a sturdy floor If the floor is not strong enough or the installation site is not adequate this may result in injury from the unit falling or tipping over Carefully with the power cord to avoid short circuit or open circuit When removing the plug from the power supply outlet grip the power supply plug not the cord Pulling the cor...

Page 5: ...or lightning rod Such grounding may cause electric shock in the case of an incomplete circuit Use a power supply outlet with ground earth to prevent electric shock If the power supply outlet is not grounded it will be necessary to install a ground by qualified engineers The medical freezeris not available to store non living things flowers or other critical articles which is not suitable for low t...

Page 6: ... strong vibration and no corrosive gases around Without the presence of a lot of dust No shaking or vibrating of the freezer Altitude of the place where the freezer is located 2000m Input voltage 220 10 V No direct sunlight or any other cooling or heating source no electromagnetic interference or the freezer will not run properly 4 2 Installation site This unit is a precision machine When select a...

Page 7: ...d transfer to other safe locations 5 Prior to put the articles inside the freezer should check if the temperature set range of this device is matching the requirement of the articles 6 Due to the Inertia of refrigeration there is a little difference between the actual temperature displayed on the controller and the set temperature This is a normal phenomenon 7 Medical freezers are storage devices ...

Page 8: ...ample of the identification function 2 Structure and composition Cabinet door body refrigeration system control system and accessories Medical refrigerators and freezers are suitable for hospitals epidemic prevention stations blood banks research institutes universities genetic engineering companies etc 3 The storage temperature inside the box can be adjusted through the temperature button on the ...

Page 9: ...e set temperature increase the set temperature value When setting the parameter value press and hold the up button for a long time and the parameter will increase rapidly Under normal conditions press and hold the key for 3 seconds to import the U disk for 12 months g is the button for set mute when there is no alarm state and the key is not unlocked press displaying ambient temperature for 5 seco...

Page 10: ...eter settings Unlock In the normal running state press the key and for 3 seconds at the same time the upper room digital tube will display the parameter code PS1 the lower room digital tube will display the parameter code 0000 press the and input the password 0005 enter the user menu password enter 0099 to restore the key lock password to the default 0005 Unlock at this time Press the key for 3 se...

Page 11: ...wer chamber low temperature alarm High ambient temperature alarm U disk generated file error Upper chamber temperature sensor alarm Low battery alarm door PF Door ajar alarm Power failure alarm EE Communication failure alarm Note When adding USB or printer ER recorder not connected and LoF recorder not activated abnormal alarm are valid 5 L01 0 0 10 0 5 0 Low temperature alarm setting value is set...

Page 12: ...re not allowed to play games in a medical freezer Caution For personal safety please cut the power supply before any maintenance Don t inhale medications or aerosols around the device while maintaining a medical freezer or it will endanger your health 7 Defrost Unused Maintenance After the product has been working for a period of time its internal surface will be frosted which will affect the cool...

Page 13: ...r with a soft cloth Once this product is activated it is best to use it continuously Note Do not spray water directly on the cabinet so as to avoid degradation of electrical components and metal parts rust Do not use hot water and corrosive cleaners or organic solvents to clean the cabinet 7 3 Disposal WARNING If the equipment is left unused in an unsupervised area for extended periods of time mak...

Page 14: ...nnected Is the power supply voltage too low or too high Whether the door is closed or the door is open too often Do you have too many items at one time Is the ambient temperature too high Temperature setting is correct or not Is the temperature inside the box too low Is the box placed on a flat floor Does the cabinet hit the wall During the rainy and humid season the window may condense which is n...

Page 15: ...m filling Fully enclosed Medical freezer Ultra low temperature freezer GL F 16M PCM color plate Epoxy polyester powder spray coated steel plate Wire tube condenser Wire Tube Evaporator Microcomputer control NTC High low temperature alarm door ajar alarm power failure alarm low battery alarm sensor error alarm Thermostat Temperature sensor ...

Page 16: ...lace it with the same roll paper The installation steps are as follows 1 Press the cylinder button on the printer and open the cover of the printer 2 put print paper into the printer box and pull the paper roll end of the printer cover after the note slightly exposed on the box cover port Annex1 Rechargeable Battery Maintenance Installation Replacement and Disposal Long term power failure or in th...

Page 17: ...nical Parameter Model Ambient tempera ture Refriger ant Rated voltage V Rated frequenc y Hz Storage temperatu re Net capacity L Rated current A Net Weight Kg Exterior dimension W D H mm Clim ate type Name Operation manual 1 10 3 Electrical Diagram Quantity Defrost shovel 1 10 2 Packing List GL F 16M 16 32 N R600a 65g 2 220 50 Up 10 25 450 1 55 144 810 735 1960 Down 10 25 ...

Reviews: