Glacier GL-F-16M Operation Manual Download Page 4

1

INTRODUCTION

1

2

Thank you for choosing Meiling's bio-medical products.Read this manual 

carefully before using the appliance and follow the instructions for the safety 
operation.Keep this manual in an adequate place to refer to it as necessary.

Meiling never guarantee any safety if the appliance is used for any objects other 

than intended use or used by any procedures other than those mentioned in this 
manual.The contents of the manual will be subjected to change without notice due 
to the improvement of performance or functions.Contact Meiling sales 
representative or agent if any point in this manual is unclear or if there are any 
inaccuracies.No part of this manual may be reproduced in any form without the 
expressed written permission of Meiling.

u

Please read the page4-page7 carefully as it contains the important safety 

notices.

u

Only trained or authorized personnel could operate this Ultra-low temperature 

freezer.

u

Only qualified service personnel or authorized agent could install and 

maintenance this device.

u

Use Meiling spare parts as always. If users want to use other accessories, 

Meiling bio-medical will not be responsible for the adverse consequences. 
However users could apply for verifying the eligibility of these accessories from 
Meiling before use them.

u

Should inspect and maintenance the device in a specified time interval.

u

Due to the differences between each models and the improvements of products, 

actual product may differ from the diagram. Please refer to the final product.

u

Everyone has an obligation to be responsible for his or her own safety.

u

Put on dry gloves when you take out refrigerated articles from the freezer. 

u

contents or the inside walls with naked hands may cause frostbit.

Handing frozen.

u

contents or the inside walls with naked hands may cause frostbit.

2. Safety

 

Notices

For the first time to use this device, uses must read the meaning of the following warning labels

very carefully. Items and procedures are described so that you can use this unit correctly and safely. 
If  the  precautions  advised  are  followed,  this  will  prevent  possible  injury  to  the  user  and  any  other 
person.

CAUTION.

Failure to observe WARNING signs could result in injury to
personnel and damage to the unit and associated property.

WARNING

Failure to observe WARNING signs could result in a hazard to 
personnel possibly resulting in serious injury or death.

WARNING. 

Failure to observe WARNING signs could result in a hazard to personnel possibly resulting in serious injury 
or death.

As with any equipment that uses CO2 gas, there is a likelihood of oxygen depletion in the vicinity of the 
equipment.It is important that you assess the work site to ensure there is suitable and sufficientventilation.If 
restricted ventilation is suspected, then other methods of ensuring asafe environment mustbe considered. 
These may include atmosphere monitoring and warning devices.

CAUTION HOT.

The sign inform the users about the danger of burns for high 
temperature.

DANGER OF EXPLOSION

The sign inform the danger of the application of volatile, 
explosive chemical substances.

NO TILTING .

STAY

 

OUT

 

OF

 

SUN

.

Do not touch any electrical parts such as the power supply plug or any switches with a wet hand.This may 
cause electric shock.

Only qualified engineers or service personnel should install the unit.
The installation by unqualified personnel may cause electric shock or fire.

Be sure to install the unit on a sturdy floor. If the floor is not strong enough or the installation site is not
 adequate, this may result in injury from the unit falling or tipping over

Carefully with the power cord to avoid short circuit or open circuit.When removing the plug from the power 
supply outlet, grip the power supply plug, not the cord.Pulling the cord may result in electric shock or fire by 
short circuit. Don't make the power line pack and pressed by furnish or heavy goods.Also please don't close 
to the compressor and heat source.

Please insert the power plug firmly to avoid leakage.

Use  a  power  supply  outlet  with  ground  (earth)  to  prevent  electric  shock.  If  the  power  supply  outlet  is  not 
grounded, it will be necessary to install a ground by qualified engineers.
Don't  lengthen  the  line  randomly.  If  you  need,  To  use  2.5mm2  copper  line,you  should  keep  4mm2  line  to 
connect the electrical outlet. Or may cause fire.

Make sure a dedicated power source is used as indicated on the rating label attached to the unit. Out of the 
rate,  should  install  a  property  transformer  and  a  proper  voltage  stabilizer  for  securely  operation.  Or  the 
freezer may be damaged, and may cause injury.

Be sure to installthe unit on a sturdy floor, no shaking and tilting.

Never install the unit in a flammable or volatile location. This may cause explosion or fire.

Never  install  the  unit  in  a  humid  place  or  outdoor  or  a  place  where  it  is  likely  to  be  basked 
straightly.Deterioration of the insulation may result which could cause current leakage or electric shock.

Do  not  place  the  devicelateral  tilt,  do  not  impact  the  device;  the  device  is  equipped  with  refrigeration 
systems, roll or shock will easily damage the freezer.

Summary of Contents for GL-F-16M

Page 1: ...www aegisfridge com OPERATION MANUAL Applicable product model GL F 16M ...

Page 2: ... 4 4 Standing 4 5 Power on for the First Time 5 Components and Overview 6 Display Panel Function Description 7 Defrost Unused Maintenance 7 1 Defrost 7 2 Unused and Maintenance 7 3 Disposal 8 After sale Service 9 Specifications 10 Performance 10 1 Main Technical Parameter 10 2 Packing List 10 3 Electrical Diagram 1 2 4 4 4 4 5 5 6 10 10 12 13 15 15 15 15 5 7 10 11 ...

Page 3: ...carefully the cautions and safety issues In order to make the device work properly please follow the correct installation method Medical freezer ultra low temperature freezer combined refrigerator and freezer can only be operated by trained and authorized personnel Maintenance of the equipment can only be carried out by agents authorized by Glacier If the operator encounters a situation not mentio...

Page 4: ...onnel may cause electric shock or fire Be sure to install the unit on a sturdy floor If the floor is not strong enough or the installation site is not adequate this may result in injury from the unit falling or tipping over Carefully with the power cord to avoid short circuit or open circuit When removing the plug from the power supply outlet grip the power supply plug not the cord Pulling the cor...

Page 5: ...or lightning rod Such grounding may cause electric shock in the case of an incomplete circuit Use a power supply outlet with ground earth to prevent electric shock If the power supply outlet is not grounded it will be necessary to install a ground by qualified engineers The medical freezeris not available to store non living things flowers or other critical articles which is not suitable for low t...

Page 6: ... strong vibration and no corrosive gases around Without the presence of a lot of dust No shaking or vibrating of the freezer Altitude of the place where the freezer is located 2000m Input voltage 220 10 V No direct sunlight or any other cooling or heating source no electromagnetic interference or the freezer will not run properly 4 2 Installation site This unit is a precision machine When select a...

Page 7: ...d transfer to other safe locations 5 Prior to put the articles inside the freezer should check if the temperature set range of this device is matching the requirement of the articles 6 Due to the Inertia of refrigeration there is a little difference between the actual temperature displayed on the controller and the set temperature This is a normal phenomenon 7 Medical freezers are storage devices ...

Page 8: ...ample of the identification function 2 Structure and composition Cabinet door body refrigeration system control system and accessories Medical refrigerators and freezers are suitable for hospitals epidemic prevention stations blood banks research institutes universities genetic engineering companies etc 3 The storage temperature inside the box can be adjusted through the temperature button on the ...

Page 9: ...e set temperature increase the set temperature value When setting the parameter value press and hold the up button for a long time and the parameter will increase rapidly Under normal conditions press and hold the key for 3 seconds to import the U disk for 12 months g is the button for set mute when there is no alarm state and the key is not unlocked press displaying ambient temperature for 5 seco...

Page 10: ...eter settings Unlock In the normal running state press the key and for 3 seconds at the same time the upper room digital tube will display the parameter code PS1 the lower room digital tube will display the parameter code 0000 press the and input the password 0005 enter the user menu password enter 0099 to restore the key lock password to the default 0005 Unlock at this time Press the key for 3 se...

Page 11: ...wer chamber low temperature alarm High ambient temperature alarm U disk generated file error Upper chamber temperature sensor alarm Low battery alarm door PF Door ajar alarm Power failure alarm EE Communication failure alarm Note When adding USB or printer ER recorder not connected and LoF recorder not activated abnormal alarm are valid 5 L01 0 0 10 0 5 0 Low temperature alarm setting value is set...

Page 12: ...re not allowed to play games in a medical freezer Caution For personal safety please cut the power supply before any maintenance Don t inhale medications or aerosols around the device while maintaining a medical freezer or it will endanger your health 7 Defrost Unused Maintenance After the product has been working for a period of time its internal surface will be frosted which will affect the cool...

Page 13: ...r with a soft cloth Once this product is activated it is best to use it continuously Note Do not spray water directly on the cabinet so as to avoid degradation of electrical components and metal parts rust Do not use hot water and corrosive cleaners or organic solvents to clean the cabinet 7 3 Disposal WARNING If the equipment is left unused in an unsupervised area for extended periods of time mak...

Page 14: ...nnected Is the power supply voltage too low or too high Whether the door is closed or the door is open too often Do you have too many items at one time Is the ambient temperature too high Temperature setting is correct or not Is the temperature inside the box too low Is the box placed on a flat floor Does the cabinet hit the wall During the rainy and humid season the window may condense which is n...

Page 15: ...m filling Fully enclosed Medical freezer Ultra low temperature freezer GL F 16M PCM color plate Epoxy polyester powder spray coated steel plate Wire tube condenser Wire Tube Evaporator Microcomputer control NTC High low temperature alarm door ajar alarm power failure alarm low battery alarm sensor error alarm Thermostat Temperature sensor ...

Page 16: ...lace it with the same roll paper The installation steps are as follows 1 Press the cylinder button on the printer and open the cover of the printer 2 put print paper into the printer box and pull the paper roll end of the printer cover after the note slightly exposed on the box cover port Annex1 Rechargeable Battery Maintenance Installation Replacement and Disposal Long term power failure or in th...

Page 17: ...nical Parameter Model Ambient tempera ture Refriger ant Rated voltage V Rated frequenc y Hz Storage temperatu re Net capacity L Rated current A Net Weight Kg Exterior dimension W D H mm Clim ate type Name Operation manual 1 10 3 Electrical Diagram Quantity Defrost shovel 1 10 2 Packing List GL F 16M 16 32 N R600a 65g 2 220 50 Up 10 25 450 1 55 144 810 735 1960 Down 10 25 ...

Reviews: