background image

МОНТАЖ GVS 200 - 202 S - 215

INSTALLATION OF GVS 200 - 202 S - 215

Стр. 3/12

MT11_A50_C_GVS_200_202S_215_GIVI_ENGITA

rev. A

2

МОНТАЖ

2

INSTALLATION

Обе  стороны линейки закрепляются болтами TCEI  M6x20
(DIN 912). Датчик прикрепляется к универсальному шарниру
болтами TCEI M8x20 или к стальному проводу болтами TCEI
M8x10.
Необходимо  удостовериться  в  том,  что  каретка  не  ударяет
по

торцевым 

крышкам

во 

время 

движения

(запас

прочности).
Подсоедините кабель и вручную пройдите всю длину
измерения, чтобы удостовериться в том, что ни линейка, ни
кабель не встречают на своем пути никаких препятствий.

Fix the two scale ends with screws TCEI M6x20 (DIN 912).
Fix  the  transducer  to the  double-effect  joint with  screws  M8x20,
or to the steel wire with screws TCEI M8x10.
Make  sure  the  carriage  does  not  hit  the  end  caps  during  the
complete movement (safety margin).
Place the cable and manually cover the entire measuring length
to make sure that both the scale and the cable are able to move
without interferences.

УСТРОЙСТВО ZERO MAGNETO SET

ACTIVATION BAR ZERO MAGNETO SET

ОГРАНИЧИТЕЛЬ
ХОДА

LIMIT SWITCH

РЕФЕРЕНТНЫЕ МЕТКИ

REFERENCE INDEXES

ЗАПАС ПРОЧНОСТИ

SAFETY MARGIN

ML = ДЛИНА ИЗМЕРЕНИЯ/

ML = MEASURING LENGTH

ИЗМЕРЕНИЯ В мм /

DIMENSIONS IN mm

Каждая линейка GVS 2xx обеспечена адаптером GV-PB для
гарантии механической совместимости с линейкой PBS-HR.

GV-PB adapter is provided with each scale GVS 2xx, to guarantee
the mechanical compatibility with PBS-HR scale.

Summary of Contents for GVS 200

Page 1: ...G GV VS S 2 20 00 0 2 20 02 2 S S 2 21 15 5 Installation Manual Self aligned Scales www givimisure it...

Page 2: ...exposed axes is recommended to prevent any damage from falling tools or material and from infiltration of oils or fluids RECOMMENDED MOUNTING POSITIONS Any kind of lever arm must be avoided A proper...

Page 3: ...EI M8x10 Make sure the carriage does not hit the end caps during the complete movement safety margin Place the cable and manually cover the entire measuring length to make sure that both the scale and...

Page 4: ...ousing and correct any misalignment Check the correct connection and the continuity of the shield which has to be connected to a grounding node with very low impedance 1 The output of the cable from t...

Page 5: ...at least 30 minutes from the last machining before interrupting the air flow The necessary compressed air flow varies between 6 and 9 normal l min per each scale Depending on the length of the measuri...

Page 6: ...f draining filters or regularly empty the glasses and replace the filtercartridges Broken obstructed or blocked air pipes Verify their integrity Damaged sealing lips Replace them and verify the respec...

Page 7: ...detected act directly on the source of disturb using EMC filters 0 5 The scale is supplied with a standard 0 5 m long cable suitable to continuous movements longer or different cables are available o...

Page 8: ...ve humidity 20 80 not condensed Reading block sliding by ball bearings Power supply 5 Vdc 5 or 10 28 Vdc 5 Current consumption 140 mAMAX with R 120 5 Vdc 100 mAMAX with R 1200 10 28 Vdc A B and I0 out...

Page 9: ...Max acceleration 30 m s 2 Required moving force 1 5 N Vibration resistance EN 60068 2 6 100 m s 2 55 2000 Hz Shock resistance EN 60068 2 27 150 m s 2 11 ms Protection class EN 60529 IP 54 standard IP...

Page 10: ...sion Max traversing speed 120 m min Max acceleration 30 m s2 Required moving force 1 5 N Vibration resistance EN 60068 2 6 100 m s2 55 2000 Hz Shock resistance EN 60068 2 27 150 m s2 11 ms Protection...

Page 11: ...have been damaged by negligence or misuse improper installation or maintenance maintenance performed by unauthorized personnel transport or any other circumstance that excludes a manufacturing fault o...

Page 12: ...TRY GIVI MISURE S r l A SOCIO UNICO Via Assunta 57 20834 Nova Milanese MB Italy C F e Iscrizione al Reg Imprese di Monza e Brianza n 04355540156 Cap Soc 51 480 00 I V Tel 39 0362 366126 Fax 39 0362 36...