26
Swiss Lifting Solutions
* must be operated with a frequency inverter
DIN EN (ISO)
classification
A3 (M3)
15 C/d
(25% ED)
A4 (M4)
30 C/d
(30% ED)
A5 (M5)
60 C/d
(40% ED)
A5 (M5)
60 C/d
(40% ED)
A5 (M5)
60 C/d
(40% ED)
A5 (M5)
60 C/d
(40% ED)
Lifting speed
50 Hz
Lifting speed
60 Hz
Motor type Number
of falls
Dead
weight
Main fuse
(400 V,
slow-blow)
Series
Load capacity [kg]
[m/min]
[m/min]
[kg]
[A]
Chain safety
5:1
6.4:1
8:1
10:1
12.5:1
16:1
LPM 250/1NL D8 PLUS
-
-
250
200
160
100
4
4.8
71 A 4
1
13
6
LP 500/1NF D8 PLUS
LP 500/1NL D8 PLUS
LP 500/1N D8 PLUS
-
-
-
-
-
-
500
500
500
400
400
400
320
320
320
250
250
250
8/2
4
8
9.6/2.4
4.8
9.6
80 B 8/2
80 A 4
80 B 2
1
1
1
23
23
23
6
6
6
LP 1000/1NF D8 PLUS
LP 1000/1NL D8 PLUS
LP 1000/1N D8 PLUS
-
-
-
-
-
-
1000
1000
1000
800
800
800
630
630
630
-
-
-
8/2
4
8
9.6/2.4
4.8
9.6
100 B 8/2
90 B 4
100 B 2
1
1
1
51
45
51
10
10
10
LP 1600/1NF D8 PLUS
LP 1600/1NL D8 PLUS
-
-
-
-
1600
1600
-
1250
-
1000
-
-
8/2
4
9.6/2.4
4.8
100 C 8/2
100 AL 4
1
1
89
84
16
16
LP 2500/1NF D8 PLUS
LP 2500/1NL D8 PLUS
-
-
-
-
2500
2500
2000
2000
-
-
-
-
8/2
4
9.6/2.4
4.8
100 C 8/2
100 AL 4
1
1
90
85
16
16
Chain safety
10:1
12.5:1
16:1
20:1
25:1
32:1
LPM 250/1SL D8 PLUS
-
-
125
100
-
-
8
9.6
71 A 4
1
13
6
LP 500/1S D8 PLUS *
LP 500/1KL D8 PLUS *
-
-
-
-
250
250
200
200
160
160
125
125
16
16
19.2
19.2
80 B 2
80 A 4
1
1
23
23
6
6
LP 1000/1S D8 PLUS *
LP 1000/1KL D8 PLUS *
-
-
-
-
500
500
400
400
-
-
-
-
16
16
19.2
19.2
100 B 2
90 B 4
1
1
51
45
10
10
LP 1600/1SL D8 PLUS
1250
1000
800
-
-
-
8
9.6
100 AL 4
1
84
16
Table 5-2 Technical data LP D8 PLUS (three-phase version)
* must be operated with a frequency inverter
DIN EN (ISO)
classification
A3 (M3)
15 C/d
(25% ED)
A4 (M4)
30 C/d
(30% ED)
A5 (M5)
60 C/d
(40% ED)
A5 (M5)
60 C/d
(40% ED)
A5 (M5)
60 C/d
(40% ED)
A5 (M5)
60 C/d
(40% ED)
Lifting speed
50 Hz
Lifting speed
60 Hz
Motor type Number
of falls
Dead
weight
Main fuse
(400 V,
slow-blow)
Series
Load capacity [kg]
[m/min]
[m/min]
[kg]
[A]
Chain safety
5:1
6.4:1
8:1
10:1
12.5:1
16:1
LPM 250/1NL D8
400
320
250
200
160
100
4
4.8
71 A 4
1
12
6
LPML 250/1NL D8
500
-
-
-
-
-
4
4.8
71 A 4
1
12
6
LP 500/1NF D8
LP 500/1NL D8
LP 500/1N D8
800
800
800
630
630
630
500
500
500
400
400
400
320
320
320
250
250
250
8/2
4
8
9.6/2.4
4.8
9.6
80 B 8/2
80 A 4
80 B 2
1
1
1
22
22
22
6
6
6
LPL 500/1NL D8
1000
-
-
-
-
-
4
4.8
80 A 4
1
22
6
LP 1000/1NF D8
LP 1000/1NL D8
LP 1000/1N D8
1600
1600
1600
1250
1250
1250
1000
1000
1000
800
800
800
630
630
630
-
-
-
8/2
4
8
9.6/2.4
4.8
9.6
100 B 8/2
90 B 4
100 B 2
1
1
1
49
43
49
10
10
10
LP 1600/1NF D8
LP 1600/1NL D8
2500
2500
2000
2000
1600
1600
-
1250
-
1000
-
-
8/2
4
9.6/2.4
4.8
100 C 8/2
100 AL 4
1
1
85
80
16
16
LP 2500/1BF D8
LP 2500/1NF D8
LP 2500/1BL D8
LP 2500/1NL D8
LP 2500/1B D8
-
-
-
-
-
3200
-
3200
-
3200
-
2500
-
2500
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
6.4/1.6
8/2
3.2
4
6.4
7.8/1.9
9.6/2.4
3.8
4.8
7.8
100 C 8/2
100 C 8/2
100 AL 4
100 AL 4
100 C 2
1
1
1
1
1
86
86
81
81
81
16
16
16
16
16
LP 2500/2BF D8
LP 2500/2NF D8
LP 2500/2BL D8
LP 2500/2NL D8
LP 2500/2B D8
-
-
-
-
-
6300
-
6300
-
6300
-
5000
-
5000
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3.2/0.8
4/1
1.6
2
3.2
3.9/1
4.8/1.2
1.9
2.4
3.9
100 C 8/2
100 C 8/2
100 AL 4
100 AL 4
100 C 2
2
2
2
2
2
86
86
81
81
81
16
16
16
16
16
Chain safety
10:1
12.5:1
16:1
20:1
25:1
32:1
LPM 250/1SL D8
-
-
125
100
-
-
8
9.6
71 A 4
1
12
6
LP 500/1S D8 *
LP 500/1KL D8 *
-
-
-
-
250
250
200
200
160
160
125
125
16
16
19.2
19.2
80 B 2
80 A 4
1
1
22
22
6
6
LP 1000/1S D8 *
LP 1000/1KL D8 *
-
-
-
-
500
500
400
400
-
-
-
-
16
16
19.2
19.2
100 B 2
90 B 4
1
1
49
43
10
10
LP 1600/1SL D8
1250
1000
800
-
-
-
8
9.6
100 AL 4
1
80
16
Table 5-1 Technical data LP D8 (three-phase version)
5.1 Technical data
5 Annex