Edit mode
31
Code no. 576074
Rev. nº 03/0418
Select whether an acoustic warning is desired at the end
of the phase (Fig. 5.12).
Function that can only be programmed in
PRO
mode.
Fig. 5.12
Programme a new phase or access the programming for
cooling. (Fig. 5.13)
Function that can only be programmed in
PRO
mode.
Fig. 5.13
Select the cooling time. Increase or decrease the cooling
time with the
and
keys (Fig. 5.14)
Maximum programmable time: 150 min;
Minimum time: 2 min.
Fig. 5.14
Select the final cooling temperature. Increase or decrease
the final cooling temperature with the
and
keys (Fig. 5.15)
Maximum programmable temperature 60 ºC (140 ºF);
Minimum temperature: 21 ºC (70 ºF).
Fig. 5.15
Next phase
Beep on end
Cooling time
Cool down temperature