27
Code no. 576074
Rev. nº 03/0418
Temperatures
Programming the drying temperatures.
Functions that can be programmed:
Programming the internal temperature of the drum
. A function that can be programmed in
EASY
mode and
PRO
mode. It allows the temperature inside the dryer drum to be programmed.
Programming the temperature of the air input.
This is a function that can only be programmed in
PRO
mode.
This allows the user to program the temperature limit for the exhaust air from the gas burner or for
the series of electric heating elements.
Mechanical action
Functions that can only be programmed in
PRO
mode.
Programming the rotation speed.
There are three preset speeds that can be selected in programming.
The rpm for each speed is set in the TABLES menu in System Tools (Section 7.1.3).
Programming the reverse rotation sequence.
There are five preset sequences that can be selected in programming.
Each sequence has three settings:
Left turn time (anticlockwise direction). Programming in minutes.
Pause time. Programming in seconds.
Right turn time (clockwise direction). Programming in minutes.
The rotation and pause times are set in the TABLES menu in System Tools (Section 7.1.3).
Alert beep and new phase
Functions that can only be programmed in
PRO
mode.
This
alert beep
can be programmed at the end of each phase.
The duration of the beep cannot be programmed.
Access to programming a new phase.
Up to a maximum of nine new phases can be programmed.
Accessing a new phase situates the programming in the
Drying duration
stage.
Cool down
Functions programmable in
EASY
mode and
PRO
mode.
End of program stage.
During the cooling stage the heating system is switched off and the rotation of the drum and the extraction
continue operating to reduce the temperature of the clothes at the end of the drying program, thereby avoid
creases in the fabrics and the risk of spontaneous combustion.
Normal cooling
. In the corresponding stage, a stage duration and a target temperature are programmed.
The program ends when one of the following conditions is satisfied.
The programmed time ends and the internal temperature of the dryer is below 60 ºC (140 ºF).
The internal temperature of the dryer is equal to or less than the programmed target temperature.
Safety cooling.
Cooling that is activated when a drying program is interrupted by pressing the
key or
by opening the door during the normal cooling stage. The program ends when the internal temperature of
the dryer is at or below 60 ºC (140 ºF).
VERY IMPORTANT!!!
The cooling stage is intended to reduce the temperature inside the drum, thereby preventing creases in
the fabrics and reducing the risk of spontaneous combustion from static electricity. As a security
measure it is highly advisable to program enough time to allow the fabrics to cool.