6: Setting the range
o
Set the required follow-up time using the adjuster (11).
o
Set the required brightness threshold with the adjuster (12). The
3
icon stands for Day
mode, i.e. switching independent of brightness, and the
2
icon for minimum brightness.
i
Should the device need to switch at the start of twilight, then set the adjuster (12) as shown
in ( 5).
o
Set the range by sliding the internal housing ( 6).
Top lock (14)
Maximum range
Centre lock (14)
Medium range
Bottom lock (14)
Minimum range
o
Measure the detection area by walking it. To do this, switch the motion detector to test
mode. Set the follow-up time to 10 seconds and the brightness value to
3
.
Connecting the controller
7: Stripping the connection cable
The connection cables are equipped with screwless terminals. For secure contacting, connect
only single-wire cables with a cross-section of maximum 2.5 mm². Observe the stripping lengths
for external cable jacketing and basic insulation ( 7).
blue, BU
N
, neutral conductor
brown, BN
8
Lamp cable
black, BK
L
, conductor
o
Insert the screwless terminals for fixing into the holders (5) of the housing cover ( 4).
82523522
19.05.2011
5/8
Observer 70