10: Connection diagram, Automatic manual mode
Installation switch S1 ( 10) can be used to switch Automatic mode on and off. Installation switch
S2 can be used to switch Manual mode on and off.
o
Lock the housing cover into the bottom of the rear housing panel, push the top down and
screw it tight with the central screw (3).
6 Appendix
6.1 Technical data
Rated voltage
AC 230 V ~
Mains frequency
50 Hz
Power consumption
approx. 1.1 W
Ambient temperature
-25 ... +55 °C
Protection rating
IP 55
Circuit breaker
max. 10 A
Installation height
approx. 2.40 m
Detection angle
approx. 70 °
run-on time
approx. 10 s ... 5 min
Connected load
Incandescent lamps
1000 W
HV halogen lamps
1000 W
Tronic transformers
750 W
Inductive transformers
750 VA
Electronic ballast
Type-dependent
Fluorescent lamps, uncompensated
500 VA
Fluorescent lamps, parallel compensated
400 VA
Switching current
Minimum switching current AC
100 mA
Contact type
µ contact
Connection
Single stranded
max. 2.5 mm²
6.2 Warranty
The warranty is provided in accordance with statutory requirements via the specialist trade.
Please submit or send faulty devices postage paid together with an error description to your
responsible salesperson (specialist trade/installation company/electrical specialist trade). They
will forward the devices to the Gira Service Center.