Dimming adjustment time

1…60 s
Basic setting: 4 s

Time from minimum
brightness until reaching
maximum brightness (dimming
speed).

Run-on time

0 s … 24 h
Basic setting: 0 s

As soon as a run-on time has
been entered, the actuator will
no longer remain on
permanently, but only for the
length of the run-on time. The
run-on time is restarted if
actuation is repeated. This
parameter is directly
connected to the "Manual
switch-off of run-on time"
parameter.
Note: The set time apply to
operation using radio
transmitters. The device is
switched immediately when
the 

Prog

 button is pressed.

Behaviour after the end of the
disabling function

On
Off
no change
Last value
Basic setting: No change

Behaviour of the output when
a block is removed.

Behaviour on voltage return

On
Off
Last value
Configured brightness
Basic setting: Off

Defines the behaviour of the
output after voltage return.

Brightness on voltage return

0...100 %
Basic setting: 100 %

Brightness value, set by the
output after voltage return
(mains voltage). The
parameter "Behaviour after
voltage return" must be set to
"Configured brightness".
Note: If the value is above the
set maximum brightness or
below the minimum
brightness, then the system
will switch to the appropriate
limit value.

32581002

10499448

13.03.2014

8/11

eNet

Radio control unit 1-10V, 1-gang Mini

Summary of Contents for eNet

Page 1: ...the end customer 2 Device components Figure 1 Device components 1 Operating mode switch 2 Button Prog 3 Status LED 4 Measuring points for voltage measurement terminals rear mounted 3 Function System...

Page 2: ...d signalling could vary from what is described here i The parameter list is in the Internet in the documentation for this device Supplementary functions with eNet server Update of the device software...

Page 3: ...ous voltages to the device or load couple the miniature circuit breakers or label them with a warning to ensure disconnection is guaranteed o Insert the actuator in the appliance box in such a way tha...

Page 4: ...r The actuator and radio transmitter exit the programming mode automatically i If the status LED of the control unit flashes 3 times at 1 second intervals for approx 5 seconds then the programming ope...

Page 5: ...r longer than 4 seconds The light switches off briefly and then switches on again to the new switch on brightness Switch on brightness is saved i Alternatively the switch on brightness can be saved wi...

Page 6: ...tory setting Operating mode Normal operation Continuous on Continuous off Basic setting Normal Operation Normal operation The output can be operated with radio transmitters and the Prog button Continu...

Page 7: ...as not yet been switched off due to the delay when a switch on command comes then the load will remain on Note The set time apply to operation using radio transmitters The device is switched immediate...

Page 8: ...he Prog button is pressed Behaviour after the end of the disabling function On Off no change Last value Basic setting No change Behaviour of the output when a block is removed Behaviour on voltage ret...

Page 9: ...is the highest priority and 4 the lowest 0 means no priority Priority restraint 0 4 Basic setting 2 Specifies the priority for recalling and removing a scene of type Forced position for the channel Pr...

Page 10: ...a level higher than the maximum brightness then the system will dim to maximum brightness Hotel function On Off Basic setting Off If the hotel function is activated the system will dim to 20 brightnes...

Page 11: ...Eliminate short circuit Lamps switch to maximum brightness No dimming is possible Cause 1 10 V control cables are interrupted or not connected Connect the control cables correctly 6 4 Accessories Ins...

Reviews: