Intended use

-

Switching and brightness setting of luminaires with 1-10 V interface

-

Operation with suitable radio transmitters

-

Mounting in appliance box according to DIN 49073 in combination with a suitable cover.

-

Installation in surface-mounted housing or panel-mounted housing (accessories) for
suspended ceilings

Product characteristics

-

Switch-on brightness can be saved permanently

-

Minimum brightness can be saved permanently

-

Scene operation possible

-

Status indicator of the 1-10 V subscribers via LED

-

Status feedback to radio transmitter

-

1-10 V subscribers switchable with 

Prog

 button

-

1-10 V interface is protected against reverse polarity 

Can be set with eNet server:
-

Maximum brightness

-

Dimming speed

-

Switch-on delay / switch-off delay

-

Dim up/dim down ramp

-

Switch-off warning

-

Operation locks

-

Continuous on, Continuous off

-

Hotel function

-

Run-on time

-

Light control

i

If settings are changed with the eNet server, operation and signalling could vary from what
is described here.

i

The parameter list is in the Internet in the documentation for this device.

Supplementary functions with eNet server: 
-

Update of the device software

-

Repeater function

-

Reading of error memory

Response after mains voltage return

The response after mains voltage return can be configured with the eNet server. Default setting:
Off.

4 Operation

Operation with radio transmitters

Operation is with radio transmitters, please observe the radio transmitter instructions.

5 Information for electrically skilled persons

5.1 Fitting and electrical connection

DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.

Mounting and connecting actuator

To ensure good transmission quality, keep a sufficient distance from any possible sources of
interference, e.g. metallic surfaces, microwave ovens, hi-fi and TV systems, ballasts or
transformers. 

32581002

10499448

13.03.2014

2/11

eNet

Radio control unit 1-10V, 1-gang Mini

Summary of Contents for eNet

Page 1: ...the end customer 2 Device components Figure 1 Device components 1 Operating mode switch 2 Button Prog 3 Status LED 4 Measuring points for voltage measurement terminals rear mounted 3 Function System...

Page 2: ...d signalling could vary from what is described here i The parameter list is in the Internet in the documentation for this device Supplementary functions with eNet server Update of the device software...

Page 3: ...ous voltages to the device or load couple the miniature circuit breakers or label them with a warning to ensure disconnection is guaranteed o Insert the actuator in the appliance box in such a way tha...

Page 4: ...r The actuator and radio transmitter exit the programming mode automatically i If the status LED of the control unit flashes 3 times at 1 second intervals for approx 5 seconds then the programming ope...

Page 5: ...r longer than 4 seconds The light switches off briefly and then switches on again to the new switch on brightness Switch on brightness is saved i Alternatively the switch on brightness can be saved wi...

Page 6: ...tory setting Operating mode Normal operation Continuous on Continuous off Basic setting Normal Operation Normal operation The output can be operated with radio transmitters and the Prog button Continu...

Page 7: ...as not yet been switched off due to the delay when a switch on command comes then the load will remain on Note The set time apply to operation using radio transmitters The device is switched immediate...

Page 8: ...he Prog button is pressed Behaviour after the end of the disabling function On Off no change Last value Basic setting No change Behaviour of the output when a block is removed Behaviour on voltage ret...

Page 9: ...is the highest priority and 4 the lowest 0 means no priority Priority restraint 0 4 Basic setting 2 Specifies the priority for recalling and removing a scene of type Forced position for the channel Pr...

Page 10: ...a level higher than the maximum brightness then the system will dim to maximum brightness Hotel function On Off Basic setting Off If the hotel function is activated the system will dim to 20 brightnes...

Page 11: ...Eliminate short circuit Lamps switch to maximum brightness No dimming is possible Cause 1 10 V control cables are interrupted or not connected Connect the control cables correctly 6 4 Accessories Ins...

Reviews: