Monthly 

  Press the test button; 

  If it emits the warning tone, the home smoke detector is in good working order. 

  If the warning tone is not emitted, please check the battery connection or replace the battery 

with a new one. If the test results are then still negative, the home smoke detector must be 
replaced. 

 

6-monthly 

  Remove the home smoke detector from its base and wipe it with a damp cloth. 

  Reinsert the home smoke detector in its base and turn it clockwise until it clicks into place. 

 

Technical data 

Sensitivity 

to prEN 12239 (95) 

Operating voltage 

9 V DC 

Current consumption 

Quiescent current 

typical 

Alarm current (type without relay) 

max.25 mA 

Alarm current (relay type) 

max.50 mA 

Relay module 

NO contacts, volt-free 

Switched voltage 

max. 30 V DC 

Switched current 

max. 1 A 

Battery rectangular 

battery 

Battery type 

ICE6 LR 61, 9 V 

Battery low power signal 

1/min, 30 days 

Alarm indicator 

LED, red 

Sounder 

85 dB (A) 

Ingress protection 

IP 42 

Ambient service temperature 

+ 5 to + 40 °C 

Storage temperature 

- 5 to + 60 °C 

VdS approval 

see nameplate on smoke detector 

Weight (without battery) 

130 g 

 

Acceptance of guarantee 

We accept the guarantee in accordance with the corresponding legal provisions.

 

Please return the unit postage paid to our central service department giving a brief description 
of the fault: 

Gira 
Giersiepen GmbH & Co. KG 

Service Center 

Dahlienstrasse 12 
D-42477 Radevormwald 
 

 

The CE sign is a free trade sign addressed exclusively to the authorities and does not include
any warranty of any properties. 

 

Gira 
Giersiepen GmbH & Co. KG 
Postfach 1220 
D-42461 Radevormwald 

Telefon:  +49 / 21 95 / 602 - 0 
Telefax:  +49 / 21 95 / 602 - 339 
Internet: www.gira.de 

Reviews: