background image

GIRA

 

Info

 

 

Smoke detector plus / VdS 

Instructions for Installation 

 

 

Smoke detector plus / VdS 

02/02 

Seite: 1 von 6 

Smoke detector plus / VdS with relay module 

 

pure white 

Art. Nr.: 0496 06  

 alu 0496 

07 

 
 

Smoke detector plus / VdS with radio transmitter module 

 

pure white 

Art. Nr.: 0496 08 

 alu 0496 

09 

 
 

Product features 

  Battery-operated stand-alone Home Smoke Detector working on photoelectric principle. 

  Automatic self-test for smoke-sensing electronics, therefore extremely reliable and immune to 

interference. 

  Option of operating as a wireless network with radio transmitter modules and a wireless alarm unit 

(available as extras). 

  Loud pulsating warning tone if smoke detected, approx. 85 dB (A). 

  Battery low-power monitor (LED and short beeps at intervals) warns that battery voltage is 

growing weaker, for up to about 30 days. 

  Contamination/fault warning function with LED and short beep. 

  Option of operating as a wired network with relay modules (available as extras). Up to 40 smoke 

detectors can be linked together. If one smoke detector identifies a fire, the alarm is relayed all the 
other smoke detectors in the network. 

  Integrated test button: if the smoke detector emits its warning tone when the test button is 

pressed, it is in good working order. 

  Simple mechanical safeguard prevents smoke detector clicking into place in its base if no battery 

is fitted. 

  Damage to the detector is not possible if the battery is installed with the wrong polarity. 

 
 

Operating principle 

The smoke detector is an early warning device for smouldering fires as well as flaming fires that 
develop smoke. It operates on the proven light scatter principle. lnside the sensing chamber a light 
source and a light sensor are arranged so that light normally does not fall on the sensor. It is only 
when airborne particles enter the chamber that light is scattered onto the sensor (Tyndall effect) to 
produce an electrical signal. This design means that no radioactive source is required. Smouldering 
fires in particular are quickly identified by the smoke detector and the alarm given. 
 
If smoke enters the sensing chamber, the built-in sounder is triggered. A logic circuit to eliminate false 
alarms delays the alarm signal and resetting by up to 30 seconds. 
 
This product has been approved by the Schadenverhütung GmbH in Cologne (VdS). Only security 
products meeting the high quality demands of the prEN 12239 receive this approval. 
Important test criteria are: 

  reliable smoke detection characteristics 

  good smoke entry 

  immunity to electrostatically discharge 

  functional check and battery presence control 

 Test 

button 

 

Reviews: