6.a)

6.1 Automatic mode

After a presence detector has been programmed into 
a radio-controlled dimming actuator, the actuator ope-
rates permanently in the automatic mode.

If the actual brightness value measured at the pre-
sence detector is below the reference brightness, the 
dimming actuator is started with full brightness 
(100 %) when presence is detected.

Thereafter, the degree of dimming is adjusted in such 
a way that the actual brightness corresponds to the 
reference value (constant lightintensity control).

If the actuator is switched off and if the shut-off delay 
is permanently retriggered by presence during the 
switch-off phase, the actuator restarts with the lowest 
dimming level when it is switched on again.

If - in the light control mode - no presence is detected 
any more during the preset shut-off delay, the dim-
ming actuator shuts off, but remains in the automatic 
mode.

The dimming actuator is also switched off at minimal 
brightness and when the reference brightness is ex-
ceeded for at least 15 minutes by 40 %.

6.2 Manual activation of the light control

To activate the light control manually when the load is 
switched off (without presence detection), depress 
briefly a key on any of the radio-control transmitters 
programmed into the radio-control.

If used with a radio-control pushbutton for switching 
and dimming the light control can also be activated lo-
cally: when the presence detector is programmed into 
the device, the light control can be terminated by de-
pressing briefly either the upper or the lower rocker of 
the pushbutton.

6.3 Manual deactivation of the light control

An active light control (load on) can be deactivated by 
a brief actuation of a programmed radio-control trans-
mitter.

Using a radio-control push-button for switching and 
dimming also permits to deactivate the light control lo-
cally by hand: when the presence detector has been 
programmed, the light control can also be terminated 
by a brief depression of the upper or the lower rocker.

The actuator remains off as long as presence is being 
detected (e.g. slide presentation). If no presence is 
detected and a reset time of about 2 min. has elaps-
ed, the actuator will return to the automatic mode.

i

Important

When the actual brightness drops below the refer-
ence brightness during the shut-off delay, the load is 
switched on even if no presence is detected.

i

Important

If no presence is detected for a period of at least 2 
minutes after manual activation, the dimming actua-
tor is switched off.

Summary of Contents for 0318 02

Page 1: ... If no movements are detected anymore the detector switches off after the preset shut off delay The detec tor is equally switched off when the upper brightness limit is exceeded For monitoring of large areas several presence de tectors can be used in common in the same system In this case one presence detector works as the mas ter unit main unit whereas all other presence detec tors work as slave ...

Page 2: ...ttach the presence detector to the baseplate only af ter having installed the batteries and programmed the presence detector into a radio control receiver To install the presence detector proceed as follows 1 Fasten the baseplate to the room ceiling using the screws supplied fig 2 c c 2 Turn the presence detector on the baseplate ap prox 45 counterclockwise until it is heard to en gage 2 c i Impor...

Page 3: ...ng of a radio control presence de tector the sensitivity of the radio control receivers is reduced to approx 5 m The distance between the re ceiver and the radiocontrol presence detector should therefore be not less than 0 5 m and not more than 5 m Programming procedure 1 When programming the first presence detector into the radiocontrol receiver make sure the brightness control fig 2 f i does not...

Page 4: ...be used to blank out undesired zones of detection The mask is snapped onto the sensor window Cut out the mask only along the marked lines fig 3 c The following data are referred to a fitting height of ca 2 50 m In this case the detection field on the floor has a diameter of ca 8 00 m 3 c Cutting out the mask changes the diameter of the de tection field on the floor as follows Full mask without cut...

Page 5: ...e radio actuator only after activation of the light control test mode After performing the setting put the ornamental ring back in place The protruding light sensor must fit into the corresponding recession in the ornamental ring 5 Setmodes 5 1 Light control test mode The light control test mode is used to preset the refer ence brightness of the presence detector Fine tuning can be done later by r...

Page 6: ...ds Activating the movement test mode To activate the movement test mode for about 10 mi nutes depress the button fig 5 c f shortly 1 s In the movement test mode the LED fig 5 c c flash es 6 times during each transmission Deactivating the movement test mode The movement test ends automatically after about 10 minutes or can be terminated by a brief depression 1 s of the button 6 Light control with a...

Page 7: ... light control manually when the load is switched off without presence detection depress briefly a key on any of the radio control transmitters programmed into the radio control If used with a radio control pushbutton for switching and dimming the light control can also be activated lo cally when the presence detector is programmed into the device the light control can be terminated by de pressing...

Page 8: ...held transmitter programmed into the dimming actuator Depress channel key 8 or of channel group C longer 1 s fig 6 b With a radio control push button for switching and dimming the temporary reference brightness value can be stored as permanent reference brightness value by depressing both rockers together double sided actuation for at least 3 seconds when the lamp is on fig 6 c This storage is con...

Page 9: ...utes has elapsed the dimming actuator switches off and returns to automa tic operation If the additional functions are terminated by switching off the dimming actuator switches off for at least 2 minutes It returns to automatic operation when no presence is detected anymore and after a fixed reten tion time of 2 minutes has elapsed 7 Light control with a switching actuator A radio control switchin...

Page 10: ...ff for 2 hours Switching on and off for 2 hours with a switching ac tuator is the same as described for the dimming actu ator cf section 6 6 7 5 Permanent change of the brightness reference value The current actual brightness can be stored in the dimming actuator as permanent reference brightness This value overwrites the reference brightness adjust ed manually on the presence detector with a hand...

Page 11: ...tion All OFF When a programmed All OFF key is pressed the ac tuator integrated into light control switches off for at least 2 minutes If no presence is detected anymore and after elapsing of a fixed retention time of 2 min utes the actuator switches off and returns to automa tic operation Master key special functions during lightscape operation The special functions during lightscape operation lis...

Page 12: ...ed brief depression of key 4 8 f The lightscape is switched off and remains in this state as long as presence is detected e g slide show This is only possible when the lightscape key last pressed is programmed in the actuator If no presence is detected and after the shut off delay of 2 minutes has passed the actuator involved in light control returns to automatic operation Returning to automatic i...

Page 13: ...s When programming the presence detectors into the radio control receiver cf section 2 Programming a detector into a radio control receiver make sure the presence detector specified as master unit is pro grammed first The brightness reference control must therefore not be set to minimum moon symbol since the detector would otherwise be identified as slave which means that it cannot be programmed a...

Page 14: ... Micro LR03 AAA Alkaline Note Never use carbon zinc batteries R 03 or rechargeable batteries Transmit frequency 433 42 MHz Modulation ASK Transmitting range max 100 m free field Coding 1 billion Angle of detection 360 Nominal range at desk level approx Ø 5 m at floor level approx Ø 8 m Fitting height for nominal range 2 5 m Shut off delay approx 2 min 1 h Brightness approx 3 2000 lx Temperature ra...

Page 15: ...d with the detector 12 Acceptance of guarantee We accept the guarantee in accordance with the corresponding legal provisions Please return the unit postage paid to our central service department giving a brief description of the fault Gira Giersiepen GmbH Co KG Service Center Dahlienstrasse 12 D 42477 Radevormwald Gira Giersiepen GmbH Co KG Postfach 1220 D 42461 Radevormwald Telefon 49 21 95 602 0...

Reviews: