background image

 

 

Carry out the test with clean needles, clean nozzle and clean device. After filling the tank with 

liquid,  we  recommend  at  least  ten  spraying  cycles  before  checking  the  total  volume  being 

sprayed in order to determine the exact ratio between set value and actual volume of liquid 

being sprayed. 

In fact the pump always carried out the number of rotations you have programmed, while the 

sprayed quantity also depends on the liquid viscosity and the load losses of the nozzle. 

 

 

Notes 

Always set the required value on the device (whenever you switch it on, the default setting is 

fixed and could be different from the requirements). 

During  the  operation  always  check  the  needle  is  not  clogged,  which  could  modify  both  the 

spraying time and sprayed quantity alike. 

Clean the appliance thoroughly after each use. 

Always cap all the needles after use and after cleaning. 

The lithium ion batteries do not have the unpleasant “memory effect” that plagued NI-Cd bat-

teries. Therefore we recommend you charge them after each operating cycle. This will extend 

the battery life and avoid being interrupted while working because of voltage loss. 

When  the  batteries  are  fully  charged  (charger  lamp  green)  we  recommend  you  unplug  the 

battery charger even if there would be no overload risks. 