Capacitor voltage may be hazardous

. To

discharge capacitor, hold insulated handle screwdriver 

by

the handle

and short capacitor terminals together. Do not

touch metal screwdriver blade or capacitor terminals.

3. With one 7/16” wrench in place on motor shaft, place

second wrench on shaft hex at pump end and unscrew
impeller stack by turning counter-clockwise.

4. Once loose from motor shaft, hold shaft by snap ring

using a pliers or similar tool, and pull stack from shell.
You may have to apply a back and forth motion to break
stack loose from shell.

To assemble with replacement impeller stack, keep pump in
the vertical position, motor down, and reverse instructions 1
through 4.

Assembly hints:

A. Apply a soapy water solution to suction and dischage

O-Rings to ease seating of shell.

B. Make sure mechanical shaft seal spring is in proper

position on motor shaft.

C. On three-phase models, apply Loctite No. 271 to

motor shaft threads before reinstalling stack.

Mechanical Seal Changeout 

(refer to Figures 1 and 2)

This procedure is best completed with the pump held in a
vertical position, motor down.

First complete 

“Disassembly”

instructions 1 through 5 under

“Impeller Stack Changeout.”

(see Figure 1, Page 2).

5. Remove 4 capscrews holding pump body to motor. 

6. Unscrew pump shell from pump body, turning clockwise

(left hand threads).

7. Remove mechanical shaft seal spring and rotating half

from motor shaft. Use care not to scratch motor shaft
when removing rotating half.

8. Remove pump body from motor and place on flat surface,

face down. Again, use care not to scratch motor shaft.

9. Use a screwdriver to push ceramic seat out from seal

cavity as shown.

10. Installation of ceramic seat:

A. Turn pump body over so seal cavity is up; clean

cavity thoroughly.

B. Clean polished surface of ceramic seat with a clean

cloth.

Ceramic Seat

3/4" pipe or
3/4" socket
with extender 

Polished
Face

Rotating
Half

Cardboard
washer (supplied
       w/seal)

Rotating Half
of Mechanical
Seal

Remove shell;
turn clockwise.

Push ceramic
seat out of
pump body

Remove
Pump Body

5

6

7

8

9

10

11

1212 0894 GS

Figure 2 – Mechanical seal changeout.

Summary of Contents for SGS327

Page 1: ...n damage internal parts overheat pump which can cause burns to people handling or servicing pump and will void warranty Do not pump chemicals or corrosive liquids with pump Hazardous Pressure A High pressure discharge stream is dangerous To avoid injury DO NOT stand in front of the discharge stream B BE SURE that the pump suction pipe pressure plus the pump discharge pressure does not exceed the p...

Page 2: ...lockwise reverse any two leads to the starter The rotation will now be correct GROUNDING THE MOTOR Ground the pump permanently using a wire of size and type specified by local or National Electrical Code MAINTENANCE Pump Disassembly Hazardous voltage Can shock burn or cause death Disconnect power to pump before servicing Tools required 1 7 16 open end wrench 2 required 2 Flat blade screwdriver wit...

Page 3: ...alling stack Mechanical Seal Changeout refer to Figures 1 and 2 This procedure is best completed with the pump held in a vertical position motor down First complete Disassembly instructions 1 through 5 under Impeller Stack Changeout see Figure 1 Page 2 5 Remove 4 capscrews holding pump body to motor 6 Unscrew pump shell from pump body turning clockwise left hand threads 7 Remove mechanical shaft s...

Page 4: ...py water Place cardboard washer over polished face of seat and press into seal cavity using a 3 4 socket or a piece of 3 4 standard pipe D Be sure polished surface of seat is free of dirt and has not been damaged by insertion Re move excess soapy water Dispose of card board washer 11 Installation of rotating half and spring A Reinstall pump body on motor using extreme caution not to hit ceramic po...

Reviews: