10. Specification

10. Specification

.51.

3/PE,480

Max. DC input voltage (Volts)

MPPT voltage range (Volts)
Max.  input current (Amps) 

MPPT number/Max input strings number

Rated grid voltage (Volts)

Power Factor (at rated output power)

Operating frequency range (Hertz)
Max.efficiency
EU efficiency

Model

Dimensions

Weight
Topology

630W*700H*357D (mm)

1100

4*22

4*34.3

4/8

50

61kg

Transformerless

Rated output power (Watts) 
Max. output power (Watts) 
Max. apparent output power (VA) 

720

50000
55000
55000

60.2

Solis-50K-HV

THDi (at rated output power)

<3% 

200...1000

Startup voltage (Volts)

200

Max short circuit input current (Amps)

Rated DC voltage (Volts)

Rated grid frequency (Hertz)

Operating ambient temperature range

Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude

IP65

<30 dBA 

Natural convection

4000m

Self consumption (night)

Relative humidity

0~100%

DC connection

Safety/EMC standard

AC connection
Display
Communication 
Warranty

OT terminal

LCD,2×20 Z.

RS485 , Optional: Wi-Fi, GPRS

 

5 years  (Extand to 20 years)

45...55

MC4 connector

Grid connection standard

Rated grid output current (Amps) 
Max. output current (Amps) 

66.2

>

0.99 (0.8 leading - 0.8 lagging)

-

25

...

+60

3/PE,480

Max. DC input voltage (Volts)

MPPT voltage range (Volts)
Max.  input current (Amps) 

MPPT number/Max input strings number

Rated grid voltage (Volts)

Power Factor (at rated output power)

Operating frequency range (Hertz)
Max.efficiency

EU efficiency

Model

Dimensions

Weight
Topology

630W*700H*357D (mm)

1100

4*28

.

5

4*44

.

5

4/12

50

63kg

Transformerless

Rated output power (Watts) 
Max. output power (Watts) 
Max. apparent output power (VA) 

720

60000
66000
66000

72.2

Solis-60K-HV

THDi (at rated output power)

<3% 

200...1000

Startup voltage (Volts)

200

Max short circuit input current (Amps)

Rated DC voltage (Volts)

Rated grid frequency (Hertz)

Operating ambient temperature range

Ingress protection
Noise emission (typical)

Cooling concept
Max.operation altitude

IP65

4000m

Self consumption (night)

Relative humidity

0~100%

DC connection

Safety/EMC standard

AC connection
Display
Communication 
Warranty

OT terminal

LCD,2×20 Z.

RS485 , Optional: Wi-Fi, GPRS

 

5 years  (Extand to 20 years)

<60 dBA 

Intelligent redundant fan-cooling

45...55

MC4 connector

Grid connection standard

Rated grid output current (Amps) 
Max. output current (Amps) 

80.0

>

0.99 (0.8 leading - 0.8 lagging)

-

25

...

+60

AS/NZS 4777.2, IEC 62116, IEC 61727, 

IEC 60068, IEC 61683, EN 50530

IEC 62109-1/-2, IEC 61000-6-2/-4

AS/NZS 4777.2, IEC 62116, IEC 61727, 

IEC 60068, IEC 61683, EN 50530

IEC 62109-1/-2, IEC 61000-6-2/-4

98.8%
98.4%

98.8%
98.4%

<1 W

<1 W

Summary of Contents for Solis

Page 1: ...blem on the inverter please find out the inverter S N and contact us we will try to respond to your question ASAP Ginlong Technologies Co Ltd No 57 Jintong Road Binhai Industrial Park Xiangshan Ningbo...

Page 2: ...allation 5 1 Select a Location for the Inverter 5 2 Mounting the Inverter 5 3 Electrical Connections 6 Start and Stop 6 1 Start the Inverter 6 2 Stop the Inverter 11 11 13 15 27 27 27 5 3 2 DC side co...

Page 3: ...Settings Technicians Only 7 5 1 Select Grid Standard 7 5 2 Grid ON OFF 8 Maintenance 9 Trouble Shooting 10 Specification 31 31 32 32 32 34 34 35 41 43 48 7 4 2 Running Message 31 7 5 3 Clear Energy 3...

Page 4: ...ous injury or death Improper use may result in potential electric shock hazards or burns This manual contains important instructions that should be followed during installation and maintenance Please...

Page 5: ...ce technician only Warranty may be voided if any unauthorized removal of cover CAUTION The surface temperature of the inverter can exceed 75 C 167 F To avoid risk of burns DO NOT touch the surface whe...

Page 6: ...e Down keys The two line Liquid Crystal Display LCD is located on the front panel of the Inverter which displays the following information 1 Inverter operation status and data 2 Service messages for o...

Page 7: ...osive materials to avoid damage to the inverter enclosure Inspect packaging regularly If packaging is damaged wet pest damage etc repackage the inverter immediately Store the inverter s on a at hard s...

Page 8: ...can be mounted to the wall or metal strut of module The mounting holes should be consistent with the size of the bracket or the dimensions shows below 1 According to the figure 5 2 select the mountin...

Page 9: ...see figure 1 2 are listed in Table 5 1 All electrical installations must be in accordance with all local and national standards Table 5 1 Electrical connection symbols GRID COM1 Connecting terminal of...

Page 10: ...istance of the grounding terminal we recommend that the External grounding terminal should be coated with silica gel or paint for protection after the installation of the grounding cable Important Fig...

Page 11: ...verter Asmall click will confirm connection as shown by the red area in Figure 5 16 Cable type Outside diameter of cable mm 4 0 6 0 5 5 9 0 Traverse area mm Range Industry generic PV cable model PV1 F...

Page 12: ...listed as follows For all AC connections 16 35mm 105 cable is accept to be used 2 Please make sure the resistance of cable is lower than 1 5 ohm If the wire is longer than 20m it s recommended to use...

Page 13: ...vice A There are 3 communication terminals for Solis inverter COM1 COM3 are all for RS485 communication COM1 is a 4 pin connector which matches with the Wi Fi or GPRS wireless communication products C...

Page 14: ...eter 9mm internal resistanc 1 5 10m and shielded RJ45 connectors are recommended Figure 5 24 RJ45 port and Terminal board 5 Installation 5 Installation Steps for connecting the RS 485 cable RS485A1 RS...

Page 15: ...When both the DC and the AC sides supply to the inverter it will be ready to generate power Initially the inverter will check both its internal parameters and the parameters of the AC grid to ensure...

Page 16: ...ows input 01 voltage value I_DC1 Shows input 01 current value V_A Shows the grid s voltage value I_A Shows the grid s current value Status Shows instant status of the Inverter Power Shows instant outp...

Page 17: ...4 1 Alarm Message The display shows the latest alarm messages see Figure 7 6 Screens can be scrolled 100 manually by pressing the UP DOWN keys Press the ESC key to return to the previous menu Alarm00...

Page 18: ...9D 55 Figure 7 14 Communication Data 7 4 7 Daily Record The screen shows history of changing settings Only for maintenance personnel The screen shows the internal data of the Inverter see Figure 7 15...

Page 19: ...1 173 236V UN G F1 47 49 5Hz 57 59 5Hz UN G V1 T 0 1 9s UN G F1 T 0 1 9s UN G V2 132 219V UN G F2 47 49Hz 57 59Hz UN G V2 T 0 1 1s UN G F2 T 0 1 9s These two functions are applicable by maintenance pe...

Page 20: ...9 IgZero_COMP Set 10 PI Set 11 IgADCheckPRO Set 12 NoSmallPulse Set This function is applicable by maintenance personnel only 7 5 8 STD Mode Settings This function is applicable by maintenance person...

Page 21: ...setting Press the ESC key to cancel changes and returns to the previous menu Figure 7 22 7 Operation 7 5 13 Fan Test Figure 7 24 Fan Test have the submenu shown below This function is applicable to ma...

Page 22: ...l lead to frequent false alarms or malfunctions Solis is not responsible for any further damages caused by unauthorized modifications The fan and filter should be regularly cleaned so as to improve th...

Page 23: ...inverter is designed in accordance with the relevant international grid tie standards along with and safety and electromagnetic compatibility requirements Before delivering to the customer the invert...

Page 24: ...t with permission from utility Check LCD voltage reading may be a bad measurement circuit Test DC Switch ON Check grid standard Replace inverter 9 Troubleshooting Alarms Cause Solution Inverter detect...

Page 25: ...ar irradiance reduces and confirm the string current is less than 0 5A with a clip on ammeter and then turn off the DC switches Please note that any damages due to wrong operations are not covered in...

Page 26: ...S 5 years Extand to 20 years IEC 62109 1 2 IEC 61000 6 2 4 10 Specification Max DC input voltage Volts MPPT voltage range Volts Max input current Amps MPPT number Max input strings number Rated grid v...

Page 27: ...5 60 3 PE 480 Max DC input voltage Volts MPPT voltage range Volts Max input current Amps MPPT number Max input strings number Rated grid voltage Volts Power Factor at rated output power Operating freq...

Reviews: