7.3 Settings
The following submenus are displayed when the Settings menu is selected:
1. Set Time.
2. Set Address.
7.3.1 Set Time
This function allows time and date setting. When this function is selected, the LCD will
display a screen as shown in Figure 7.3.
NEXT=<ENT> OK=<ESC>
01-01-2016 16:37
Figure 7.3 Set Time
Press the UP/DOWN keys to set time and date. Press the ENTER key to move from one
digit to the next (from left to right). Press the ESC key to save the settings and return to
the previous menu.
7.3.2 Set Address
This function is used to set the address when multiple inverters are connected to single
datalogger.
The address number can be assigned from “01”to “99”(see Figure 7.4). The default address
number of Solis Three Phase Inverter is “01”.
7.4 Advanced Info - Technicians Only
1. Alarm Message 2. Running message 3. Version 4. Daily Energy 5. Monthly Energy
6. Yearly Energy 7. Daily Record 8. DSP Communication Data 9. Warning Message
The screen can be scrolled manually by pressing the UP/DOWN keys. Pressing the ENTER
key gives access to a submenu. Press the ESC key to return to the Main Menu.
7.4.1 Alarm Message
The display shows the
latest alarm messages (see Figure 7.6). Screens can be scrolled
100
manually by pressing the UP/ DOWN keys. Press the ESC key to return to the previous
menu.
Alarm001: OV-G-V
Time: 27-11 Data: 7171
Figure 7.6 Alarm Message
NOTE:
Access to this menu is for fully qualified and accredited technicians only.
Entrance to “Advanced Info” and “Advanced Settings” requires a password.
YES=<ENT> NO=<ESC>
Password:0000
Figure 7.5 Enter password
Select “Advanced Info.” from the Main Menu. The screen will require the password as below.
The default password is “0010". Please press “down” to move the cursor, press “up” to
change the digit.
YES=<ENT> NO=<ESC>
Set Address: 01
Figure 7.4 Set Address
Press the UP/DOWN keys to set the address. Press the ENTER key to save the settings.
Press the ESC key to cancel the change and return to the previous menu.
7. Operation
7. Operation
.31.
.30.
Figure 7.2 Locks and Unlocks the Screen of LCD
(b)
(a)
Pressing the ESC key returns to the Main Menu. Pressing the ENTER key locks
(Figure 7.2(a)) or unlocks (Figure 7.2 (b)) the screen.
5.2 Stop the Inverter
7.2.1 Lock screen
7.4.2 Running Message
This function is for maintenance personnel to get running message such as internal
temperature, Standard NO. etc.
Screens can be scrolled manually by pressing the UP/DOWN keys.