This function is used to select the grid's reference standard (see Figure 7.16).
YES=<ENT> NO=<ESC>
Standard:AUS-Q-0.8
Figure 7.16
7.5.1 Selecting Standard
7.5 Advanced Settings - Technicians Only
Select Advanced Settings from the Main Menu to access the following options:
1. Select Standard 2. Grid ON/OFF 3. Clear Energy 4. New Password
5. Power Control 6. Calibrate Energy 7. Special Settings 8. STD. Mode Settings
9. Restore Settings 10. HMI Updater 11. Reset HMI 12. Debug Parameter
13. Fan Test 14. Power Parameter
NOTE:
Access to this area is for fully qualified and accredited technicians only.
Please follow 7.4 to enter password to access this menu.
7. Operation
7. Operation
Selecting the “User-Def” menu will access to the following submenu (see Figure 7.17).
Figure 7.17
OV-G-V1: 260V
OV-G-V1-T: 1S
Below is the setting range for “User-Def”. Using this function, the limits can be changed
manually.
OV-G-V1: 236---335V OV-G-F1: 50.2-53Hz(60.2-63Hz)
OV-G-V1-T: 0.1---9s OV-G-F1-T: 0.1---9s
OV-G-V2: 248---341V OV-G-F2: 51-53Hz(61-63Hz)
OV-G-V2-T: 0.1---1s OV-G-F2-T: 0.1---9s
UN-G-V1: 173---236V UN-G-F1: 47-49.5Hz(57-59.5Hz)
UN-G-V1-T: 0.1---9s UN-G-F1-T: 0.1---9s
UN-G-V2: 132---219V UN-G-F2: 47-49Hz(57-59Hz)
UN-G-V2-T: 0.1---1s UN-G-F2-T: 0.1---9s
These two functions are applicable by maintenance personnel only, wrong
operation will prevent the inverter from working properly.
.35.
.34.
NOTE:
The " User-Def" function can be only used by the service engineer and
must be allowed by the local energy supplier.
NOTE:
For different countries, the grid standard needs to be set as different
according to local requirements. If there is any doubt, please consult
Solis service technicians for details.
Range for User-Def
7.5.2 Grid ON/OFF
Grid ON
Grid OFF
Figure 7.18 Set Grid ON/OFF
Screens can be scrolled manually by pressing the UP/DOWN keys. Press the ENTER key
to save the setting. Press the ESC key to return to the previous menu.
This function is used to start up or stop the power generation of the inverter. (see Figure 7.18).
Enter the current password before setting a new password. Press the DOWN key to move the
cursor. Press the UP key to change the digit. Press the ENTER key to execute the setting.
Press the ESC key to return to the previous menu.
7.5.4 New Password
Figure 7.19 Set new password
YES=<ENT> NO=<ESC>
Password: 0000
7.5.3 Clear Energy