background image

 

Operator

s Manual

 

MO080-IT 

12/09/2017 

Rev.3 

Page 7 of 20 

 

1.5  Warranty Certificate

 

1.

 

The Product is covered by an 18-month warranty, including electrical parts 

2.

 

The warranty begins on the date of product shipment from the GIMA warehouse to the buyer. 

3.

 

In case of disputes, the date indicated on the “transport document” attached to the goods shall be deemed 
valid. 

4.

 

The  warranty  only  covers  the  sending  of  Product  spare  parts  to  the  buyer  or,  in  the  event  of  GIMA 

considering the replacement of spare parts not  feasible, the replacement of the entire product, after fabrication 
faults have been properly ascertained at the undisputable judgement of GIMA . The warranty does not therefore 
cover any other costs or expenses (including, by way of example but without limitation, labour costs, packaging 
costs and transport costs, etc.). 
5.

 

The guarantee does not include the components subject to normal wear, such as halogen bulbs, LEDs, fuses, 

relays, ball bearings, etc.) 
6.

 

The warranty does not cover: 

-

 

malfunctions due to failure to comply with all instruction manuals; 

-

 

malfunctions due to installation and/or maintenance errors; 

-

 

malfunctions or faults caused by carelessness, negligence, incorrect use or other causes not attributable to 
GIMA; 

-

 

malfunctions or faults due to the fact that the electrical system of the premises where the device is installed 
is not in compliance with CEI 64-8 standards (standards for electrical systems in premises used for medical 
purposes) and similar standards. 

7.

 

GIMA GIMA shall repay direct damages suffered by the buyer and which are documented as attributable to 

its product, caused within the warranty period, for an amount not above 40% of the net value of the product as 
indicated on the buyer’s invoice. GIMA’s liability is expressly ruled out for indirect damages or consequential 
damages (including cases of the lamp not being used) deriving from the supply. 
8.

 

This warranty certificate replaces legal warranties for faults and non-conformities and rules out any other 

possible liability of GIMA originating from the supplied products. 
9.

 

The payment of any damages to persons or things due to product malfunction or faults shall be limited to 

the maximum amount of GIMA’s insurance coverage for civil liability. 
10.

 

The warranty shall be automatically invalidated in the event of: 

-

 

the Product having been tampered with or modified by the buyer or third parties; 

-

 

the  Product  having  been  repaired  by  the  buyer  or  third  parties,  without  following  the  instructions  in  the 

instruction manuals; 

 

the Product serial number having been cancelled, defaced or removed; 

 

the buyer not being up to date with payments. 

11.

 

For jobs to be done under warranty, the buyer shall contact GIMA only. 

12.

 

The component parts replaced under warranty must only be returned to  GIMA, if so requested by GIMA, 

carriage free and suitably packed. 
13.

 

In case of failure to return a part requested by GIMA, the cost of the component part will be charged. 

14.

 

GIMA cannot accept returns from end users or in any case from parties other than the buyer. 

15.

 

Products  returned  to  GIMA  must  be  complete  with  documentation  authorising  such  return  and  another 

document describing the malfunction. 
16.

 

For everything not indicated on this warranty certificate, reference shall be made to the laws of Italy 

17.

 

For all disputes deriving from or related to  the orders to which this warranty certificate applies and which 

cannot be amicably settled between the parties, the only competent law court shall be that of Milan. 

Summary of Contents for PRIMALED SO

Page 1: ...ing the structure to the wall tube 8 2 3 Connecting up the electrical system 8 2 4 Handpiece fitting 9 2 5 First switch on 9 2 6 Check the result of Product installation and testing before use 9 3 Importance of personal safety 9 3 1 Intended use 9 3 2 Environmental conditions 9 3 3 Safety conditions secondary effects 10 3 4 Controls to be performed every time before the lamp is used 10 4 Descripti...

Page 2: ... Italian reference shall always be made to the Italian edition of this operator s manual 1 General information THE EM Electro Medical DEVICE to which this manual refers is a LAMP for diagnosis or observation For ease of description in this manual this EM EQUIPMENT will be called Product This manual is an integral part of the Product as indicated by European Directives 93 42 EEC and 2007 47 EC Alwa...

Page 3: ...cations provided by the insert manufacturers and shown below for your better information Anchor tie rod do mm t mm hs mm l mm Mt Nm SW mm x mm HSL 3 G M 8 20 12 80 60 98 25 13 20 do Nominal drill bit diameter Mt Closing bending moment t Minimum drilling depth Sw Key opening hs Minimum insertion depth Anchor tie rod length x Fastening height 1 Using the paper template provided and attached to this ...

Page 4: ...tances in the environment separate the various internal component parts such as iron aluminium plastic and electrical material and dispose of these through authorized channels so as to ensure correct recycling 1 2 Packaging transport storage and characteristics of installation premises Boxes containing the Product together with operator s manual Transport is made by GIMA or any road hauler as long...

Page 5: ...IT 12 09 2017 Rev 3 Page 5 of 20 Do not stack packaging Weight of packaging Protect from rain Weight of packaging I ON power Weight of packaging Stand By O OFF power L Line lead connection point N Neutral lead connection point ...

Page 6: ...sis Part 2 General requirements for basic safety and essential performance Collateral Standard Electromagnetic disturbances Requirements and tests Classification with reference to article 9 and Annex IX of Directives 93 42 EEC and 2007 47 EC DURATION Short term duration Annex IX Par 1 Definitions art 1 subsection 1 1 DESCRIPTION Non invasive medical device Annex IX Par 1 Definitions art 1 subsecti...

Page 7: ... not above 40 of the net value of the product as indicated on the buyer s invoice GIMA s liability is expressly ruled out for indirect damages or consequential damages including cases of the lamp not being used deriving from the supply 8 This warranty certificate replaces legal warranties for faults and non conformities and rules out any other possible liability of GIMA originating from the suppli...

Page 8: ...to the desired size in relation to the height of the room make the cut on the side of the tube 3 opposite to that bearing the fastening holes 4 of the horizontal arm To define the correct length of the tube use the table shown the suggested distance between floor and lamp headpiece is 200cm Drawing 56 Fit the anchor tube 1 until it is up against the hub of the ceiling plate 2 keeping the cut side ...

Page 9: ... M4 screws which sustain the horizontal arm are tight 6 Check the Product earth connection and make sure the clamps are well tightened 7 Make sure movement mechanisms are working properly 8 After switch on the Product must emit light from the headpiece Installer s stamp and signature 3 Importance of personal safety 3 1 Intended use The Product has been designed to light up the area of the patient ...

Page 10: ...uate intensity The flexible arm remains in the selected position without falling 4 Description and operation 4 1 Description The Product locally lights up the patient s body thanks to 9 LEDs focalized by means of specific lenses 3 non focalized LEDs are also fitted to permit using a courtesy or reading light Positioning the light beam is made easy thanks to the articulated arm and is done manually...

Page 11: ...use disinfectants which are chlorine and halogen free to prevent the plastic parts becoming fragile use only disinfectants with low alcohol content dose the disinfectants so no liquids penetrate inside the lamp elements and into the support arm system Clean the Product with a damp but not wet cloth The Product is best disinfected every time before use To clean the lamp the support need not be remo...

Page 12: ...uses If any one of the fuses is damaged replace it as indicated in section 6 6 If the product still does not work contact the assistance service 2 The Product does not remain in position See par 10 If after adjustment the product still fails to remain in position contact the GIMA after sales service 3 The light flickers Contact the after sales service 4 The light beam is not focalised Contact the ...

Page 13: ...ption Order code Fuse T1AH 250V 5x20 Z400208 Sterilisable grip Z100848 Drawing 190 To access the fuses loosen the 3 dowels 1 of the ring 2 Remove the bar cover 3 by pulling downwards Drawing 191 Remove the fuse carrier 6 from the terminal board and replace the fuse 7 making sure it is replaced with another of the same type ...

Page 14: ...mance Distribution of minimum and adequate lighting luminous flux emitted by the ME equipment does not vary by more than 20 during use and the colour temperature and the colour rendering index are stable and are within the range 3000K 6700K and 85 100 respectively Limitation of energy in the operating field UV irradiance for wavelengths below 400 nm does not exceed 10 W m2 and the total irradiance...

Page 15: ...Operator s Manual MO080 IT 12 09 2017 Rev 3 Page 15 of 20 8 Wiring diagram ...

Page 16: ... uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF Emissions CISPR 11 Class A The Product is suitable for use in all establishments other than domestic and may be used in domestic establishments and those directly connected to the public low voltage power supply network that supplies ...

Page 17: ...that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT For 0 5 cycle 40 of UT 60 dip in UT For 5 cycles 70 of UT 30 dip in UT For 25 cycles 5 UT 95 dip in UT For 5 sec 5 UT 95 dip in UT For 0 5 cycle 40 of UT 60 dip in UT For 5 cycles 70 of UT 30 dip in UT For 25 cycles 5 UT 95 dip in...

Page 18: ...tion distance d 1 2 P 150 KHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 2 3 P 80 MHz to 2 5 GHz where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacture and d is the recommended separation distance in meters m Field strengths from fixed transmitters as determined by an electromagnetic site survey should be less than the compliance leave in each ...

Page 19: ...of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 24 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable ...

Page 20: ... the small moving arms ROTATION JOINTS ADJUSTMENT PROCEDURE Using the Allen key adjust the screw alongside the joint in question Turn clockwise to increase the force of the clutch and stiffen movement Turn anti clockwise to reduce the force of the clutch and loosen movement After making adjustment movement should be smooth and uniform The clutches on the horizontal arm can also be adjusted To adju...

Page 21: ...Drawing code Rev Data 052 1 2 3 ...

Page 22: ...Drawing code Rev Data 053 1 2 3 ...

Page 23: ...Drawing code Rev Data 054 2 1 3 4 ...

Page 24: ... B 2 Tube length list mm Tabella lunghezze tubo mm L H mm L mm 2440 200 2450 210 2500 260 2550 310 2600 360 2650 410 2700 460 2750 510 2800 560 2850 610 2900 660 2950 710 3000 760 3050 810 3100 860 3150 910 3200 960 1 1 3 4 2000 L H ...

Page 25: ...Drawing code Rev Data 056 2 1 3 4 5 ...

Page 26: ...Drawing code Rev Data 057 3 1 2 ...

Page 27: ...Drawing code Rev Data 058 2 1 3 4 ...

Page 28: ...Drawing code Rev Data 1 2 7 3 4 5 6 153 ...

Page 29: ...Drawing code Rev Data 190 1 2 3 4 5 6 8 7 ...

Page 30: ...Drawing code Rev Data 191 1 2 4 5 3 6 7 ...

Page 31: ......

Page 32: ......

Reviews: