GIMA D 500
cap_3 GIMA D500 GB
3.5
For each function do as follows:
-
press
SET
: the two arrows appear
-
through the keys
UP
and/or
DOWN
choose the new value for the months
-
press
F
to confirm and go out of the menu
or
-
press
SET
to confirm and remain into the function
3.4 Alarm messages
In case of some functioning problem, the alarm system shows lighting messages on the display, stopping the
thermoregulator functioning.
Stop immediately the pouches infeed ( the pouches transport is still activated )
When an alarm occurs, the system stops immediately the pouches transport; so, if some pouches are
blocked into the machine, to avoid possible rests of melt material, do the expulsion command (par.
3.2.3)
3.4.1 Sealing bars temperature control message
Display visualization:
The message origins every time the actual bars temperature is higher or lower than the allowed range of functioning.
Action
: the machine stops the pouches transport until the temperature re-enter the allowed range of functioning (
5°
than the SET)
RESET Procedure: wait
The appearance of the message is normal every new change of the SET temperature
3.4.2 Message control battery data maintenance
display visualization :
- - - - - - - -
Action
: the machine doesn’t do corrective actions
RESET Procedure: change battery data maintenance (see electric diagram).
When the battery is discharged you loose the following data:
-
current hour
-
current data
which must be inserted every new switch on of the machine.
1 7 2 ° C
1 6 0 !