background image

INSTALLATION INSTRUCTIONS

IFW 66 SERIES INFRA RED WARMER

5925 Heisley Road • Mentor, OH 44060-1833

Decorator Hood

IFW 66 Series

FL-2194

Rev. 5 (07/10)

Page 1 of 2

Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

ELECTRICAL SPECS:

VOLTS WATTS

AMPS

HERTZ PHASE

NEMA

120

250

2.0

60

1

5-15

240

275

1.1

60

1

6-15

Warmer should be installed by an experienced 
electrician.

U.L. REQUIREMENTS:

A. Wires of warmers to be connected to 75°C wire.

B. Wires are to be installed in conduit.

C. Warmers are not to be installed any closer than 1” from 

a wall.

D. Warmers must be 

at least

 16” above a combustible 

surface.

HOW TO INSTALL:

Numbers in parentheses correspond to numbers in callouts.

Remove the two screws from the canopy and pull off 

1. 

the canopy.

Run the cord (1) up through the canopy, through the 

2. 

strain relief and the threaded nipple. Tighten the strain 
relief. Cut the cord to the desired length.

Mount the strap to the electrical outlet box with two 

3. 

screws provided.

Wire the warmer leads to the outlet box leads.

4. 

Attach the ground wire to the ground hold in the strap 

5. 

with the green ground screw.

Re-attach the canopy with the two screws.

6. 

Screw the bulb (4) into socket.

7. 