VEGA SURGICAL ASPIRATOR is a medical device powered by 230V ~ 50Hz electricity, to be used for nasal, 

oral, tracheal aspiration of body fluids, such as mucus, phlegm and blood, in adults or children. Luminaire 

designed to offer ease of transport and continuous use.

Thanks to these features and its performance, this product is particularly suitable for use in hospital wards, for 

minor surgery applications and post-operative treatments at home. Built with a plastic body with high thermal 

and electrical insulation in compliance with European safety regulations, the appliance is supplied with a com-

plete suction tank in sterilizable polycarbonate, with overflow valve, and is equipped with a suction regulator 

and vacuum gauge placed on the front panel.

 GENERAL WARNING

Read instruction manual carefully before use. 

The device is for use by qualified personnel (surgeon / professional nurse / assistant) 

The use of the device at home is restricted to an adult in full possession of mental faculties and / or home 

carers 

The instrument must not disassembled. For technical service always contact Gima S.p.A.

IMPORTANT SAFETY RULES

1. Check the condition of the unit before each use. The surface of the unit should carefully be inspected for 

visual damage. Check the mains cable and do not connect to power if damage is apparent; 

2. Before connecting the appliance always check that the electric data indicated on the data label and the type 

of plug used, correspond to those of the mains electricity to which it’s to be connected; 

3. Respect the safety regulations indicated for electrical appliances and particularly:

-  Use original components and accessories provided by the manufacturer to guarantee the highest effi-

ciency and safety of the device; 

-  The device can be used only with the bacteriological filter;

-  Never immerge the appliance into water;

-  Do not place or store the aspirator in places where it may fall or be pulled into the bathtub or washbasin. 

In the event it is accidentally dropped, do not attempt to remove the device from the water whilst the plug 

is still connected: disconnect the mains switch, remove the plug from the power supply and contact the 

GIMA technical service department. Do not attempt to make the device work before it has been thorough-

ly checked by qualified personnel and/or the GIMA technical service department. 

-  Position the device on stable and flat surfaces in a way that the air inlets on the back aren’t obstructed;

-  To avoid incidents, do not place the aspirator on unstable surfaces, which may cause it to accidentally fall 

and lead to a malfunction and/or breakage. Should there be signs of damage to the plastic parts, which 

may expose inner parts of the energised device, do not connect the plug to the electrical socket. Do not 

attempt to make the device work before it has been thoroughly checked by qualified personnel and/or the 

GIMA technical service department. 

-  Don’t use in the presence of inflammable substances such as anaesthetic, oxygen or nitrous oxide;

-  Don’t touch the device with wet hands and always prevent the appliance coming into contact with liquids;

-  Don’t leave the appliance connected to the power supply socket when not in use;

-  Don’t pull the power supply cable to disconnect the plug remove the plug from the mains socket correctly;

-  Store and use the device in places protected against the weather and far from any sources of heat. After 

each use, it is recommended to store the device in its own box away from dust and sunlight. 

-  In general, it is inadvisable to use single or multiple adapters and/or extensions. Should their use be 

necessary, you must use ones that are in compliance with safety regulations, however, taking care not to 

exceed the maximum power supply tolerated, which is indicated on the adapters and extensions.

-  Prevent children from using the device without proper supervision;

4. For repairs, exclusively contact technical service and request the use of original spare parts. Failure to 

comply with the above can jeopardise the safety of the device; 

5. Use only for the purpose intended. Don’t use for anything other than the use defined by the manufacturer. 

The manufacturer will not be responsible for damage due to improper use or connection to an electrical 

system not complying with current regulation. 

6. The  medical  device  requires  special  precautions  regarding  electromagnetic  compatibility  and  must  be 

installed and used in accordance with the information provided with the accompanying documents: the 

VEGA SUCTION UNIT device must be installed and used away from mobile and portable RF communica-

Summary of Contents for 28210

Page 1: ...HIRURGISCHER ABSAUGER VEGA ASPIRADOR QUIR RGICO VEGA APARELHO DE SUC O CIR RGICO VEGA M28210 M Rev 7 12 20 PROFESSIONAL MEDICAL PRODUCTS Gima S p A Via Marconi 1 20060 Gessate MI Italy gima gimaitaly...

Page 2: ...rtment Do not attempt to make the device work before it has been thorough ly checked by qualified personnel and or the GIMA technical service department Position the device on stable and flat surfaces...

Page 3: ...nce they contain small parts that may be swallowed 14 Do not leave the device unattended in places accessible to children and or persons not in full possession of mental facultiesas they may strangle...

Page 4: ...on pump is used on patients in unknown pathological situations and where an assess ment of indirect contamination is not possible The filter is not manufactured to be decontaminated dismantled and or...

Page 5: ...of local laws and regulations The jug and lid can be further disinfected using a common disinfectant strictly following the instructions and dilution values provided by the manufacturer At the end of...

Page 6: ...nents list descriptions setting in structions and any other information that can help the technical assistance staff for product repair BEFORE EVERY CHECKING OPERATION IN CASE OF ANOMALIES OR BAD FUNC...

Page 7: ...the presence of liquids or other visible contamination secretions In the presence of liquids or other visible contamination immediately replace the medical device due to the risk of an insufficient v...

Page 8: ...d cables sold by the appliance and system manufacturer as spare parts can lead to an increase in emissions or in a decrease of the immunity of the device or system The following tables supply informat...

Page 9: ...ains power quality should be that of a typi cal commercial environment or hospital If the user of the VEGA SUCTION UNIT request that the appliance operates continuously the use of a continuity unit is...

Page 10: ...es such as changing the device s direction or positioning may be necessary b The field intensity on an interval frequency of 150 kHz to 80 MHz should be less than 3 V m Recommended separation distance...

Page 11: ...EEE disposal Class II applied Serial number Temperature limit Fuse Atmospheric Pressure limit IP21 Covering Protection rate Alternating current ON Hz Mains frequency OFF Humidity limit SYMBOLS Disposa...

Reviews: