Where 

P

 is the maximum nominal output voltage of the

transmitter in Watt (W) depending on the manufactur-

er of the transmitter and the recommended separation 

distance in metres (m). The intensity of the field from 

the  fixed  RF  transmitters,  as  determined  by  an  elec-

tro-magnetic study of the site

a)

, could be lower than the 

level of conformity of each frequency interval 

b)

It is possible to check for interference in 

proximity to devices identified by the fol-

lowing symbol:

Note 1:

 

At 80 MHz and 800 MHz the interval with the highest frequency is applied

Note 2:

 

These guide lines may not be applicable in all situations. The electro-magnetic propagation is influenced by the

absorption and by reflection from buildings, objects and people.
a) The field intensity for fixed transmitters such as the base stations for radiotelephones (mobile and cordless) and terres-

trial mobile radio, amateur radio devices, radio AM and FM transmitters and TV transmitters can not be theoretically and 

accurately foreseen. To establish an electro-magnetic environment generated by fixed RF transmitters, an electro-magnet-

ic study of the site should be considered. If the field intensity measured in the place where the device will be used surpass-

es the above mentioned applicable level of conformity, the normal functioning of the device should be monitored. If abnor-

mal performance arises, additional measures such as changing the device’s direction or positioning may be necessary.

b) The field intensity on an interval frequency of 150 kHz to 80 MHz should be less than 3 V/m.

Recommended separation distance between portable and mobile radio-communication devices and the monitor
The VEGA SUCTION UNIT surgical aspirator is intended to operate in an electro-magnetic environment where RF irra-

diated interferences are under control. The client or operator of the VEGA SUCTION UNIT device can help prevent elec-

tro-magnetic interference by keeping a minimum distance between the portable and mobile RF communication devices 

(transmitters) and the VEGA SUCTION UNIT device, as recommended below, in relation to the radio-communication 

maximum output power.
Maximum nominal

output power of the

Transmitter W

Separation distance from the frequency transmitter (m)

150KHz to 80MHz

80MHz to 800MHz

800MHz to 2,7GHz 

0,01

0,12

0,12

0,23

0,1

0,38

0,38

0,73

1

1,2

1,2

2,3

10

3,8

3,8

7,3

100

12

12

23

For transmitters with a maximum nominal output power not shown above, the recommended separation distance in metres 

(m) can be calculated using the equation applicable to the transmitter frequency, where 

P

 is the maximum nominal output 

power of the transmitter in Watt (W) depending on the transmitter’s manufacturer.

Note 1: At 80 MHz and 800 MHz the interval with the highest frequency is applied

Note 2: These guide lines may not be applicable in all situations. The electro-magnetic propagation is influenced by the

absorption and by the reflection from buildings, objects and people

3,5

 V

1

√P

d

=

12

 E

1

√P

d=

 

23

 E

1

√P

d=

Summary of Contents for 28210

Page 1: ...HIRURGISCHER ABSAUGER VEGA ASPIRADOR QUIR RGICO VEGA APARELHO DE SUC O CIR RGICO VEGA M28210 M Rev 7 12 20 PROFESSIONAL MEDICAL PRODUCTS Gima S p A Via Marconi 1 20060 Gessate MI Italy gima gimaitaly...

Page 2: ...rtment Do not attempt to make the device work before it has been thorough ly checked by qualified personnel and or the GIMA technical service department Position the device on stable and flat surfaces...

Page 3: ...nce they contain small parts that may be swallowed 14 Do not leave the device unattended in places accessible to children and or persons not in full possession of mental facultiesas they may strangle...

Page 4: ...on pump is used on patients in unknown pathological situations and where an assess ment of indirect contamination is not possible The filter is not manufactured to be decontaminated dismantled and or...

Page 5: ...of local laws and regulations The jug and lid can be further disinfected using a common disinfectant strictly following the instructions and dilution values provided by the manufacturer At the end of...

Page 6: ...nents list descriptions setting in structions and any other information that can help the technical assistance staff for product repair BEFORE EVERY CHECKING OPERATION IN CASE OF ANOMALIES OR BAD FUNC...

Page 7: ...the presence of liquids or other visible contamination secretions In the presence of liquids or other visible contamination immediately replace the medical device due to the risk of an insufficient v...

Page 8: ...d cables sold by the appliance and system manufacturer as spare parts can lead to an increase in emissions or in a decrease of the immunity of the device or system The following tables supply informat...

Page 9: ...ains power quality should be that of a typi cal commercial environment or hospital If the user of the VEGA SUCTION UNIT request that the appliance operates continuously the use of a continuity unit is...

Page 10: ...es such as changing the device s direction or positioning may be necessary b The field intensity on an interval frequency of 150 kHz to 80 MHz should be less than 3 V m Recommended separation distance...

Page 11: ...EEE disposal Class II applied Serial number Temperature limit Fuse Atmospheric Pressure limit IP21 Covering Protection rate Alternating current ON Hz Mains frequency OFF Humidity limit SYMBOLS Disposa...

Reviews: