Gilson VALVEMATE User Manual Download Page 33

2-20

Installation

2

Checking V

alve Position and Liquid Flow

Checking Valve Position and
Liquid Flow

Refer to the appropriate procedures below.

Hamilton 86905 valve. To verify that the valve is

properly installed:

1 Fill a syringe.

2 Connect the syringe to the top left-side port and

dispense liquid into the port.

3 Verify that the liquid exits the top right-side port.

If it does not, remove the valve, orient the valve

in its home position, and install the valve again.

(Refer to page 

2-12

.) Then repeat steps 1–3.

4 Press the up arrow key.

5 Dispense additional liquid into the top left-side

port.

6 Verify that the liquid exits the bottom left-side

port.

Hamilton 86913, 86915, or 86918 valve. To verify

that the valve is properly installed:

1 Fill a syringe.

2 Connect the syringe to the center port and

dispense liquid into the port.

3 Verify the liquid exits the right-side port. If it

does not, remove the valve, orient the valve in

its home position, and install the valve again.

(Refer to page 

2-13

.) Then repeat steps 1–3.

4 Press the up arrow key.

5 Dispense additional liquid into the center port.

6 Verify that the liquid exits the port that is one

position counterclockwise from the previous

port.

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for VALVEMATE

Page 1: ...ess underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demo...

Page 2: ...VALVEMATE Valve Actuator User s Guide LT3331 2002 Gilson Inc All rights reserved December 2002 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 4: ...te 2 11 Valve Installation or Replacement 2 12 Before You Begin 2 12 Placing Replacement Valve In Its Home Position 2 12 Attaching the Valve Adapter 2 15 Removing the Installed Valve 2 18 Selecting th...

Page 5: ...d Accessories High Pressure Valves Stainless Steel A 1 High Pressure PEEK Valves A 2 Low Pressure Teflon Valves A 2 Low Pressure Hamilton Valves A 2 Replacement Valves A 3 Mounting Adapter Kits A 4 Ac...

Page 6: ...s le Bel France Type of Equipment Laboratory Equipment Model VALVEMATE Valve Actuator Beginning with Serial Number 330K0A207 Month and Year of Manufacture October 2000 Place Middleton WI USA Michael J...

Page 7: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 8: ...You can change the valve position by pressing the up or down arrow key on the front panel Unit ID mode You use this mode to view and modify the identification number assigned to the VALVEMATE Baud rat...

Page 9: ...ediately Many carriers must receive concealed damage claims within seven days of delivery VALVEMATE module with appropriate valve installed if the valve was ordered along with the VALVEMATE GSIOC cont...

Page 10: ...or if you are in the United States call the Gilson Customer Service Department at 800 445 7661 or 608 836 1551 You can also contact the Customer Service Department via its e mail address service gilso...

Page 11: ...LVEMATE generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of the...

Page 12: ...1 5 Introduction 1 Repair and Return Policies Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 13: ...1 6 Introduction 1 Technical Specifications Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 14: ...2 1 2 Installation This section takes you through the steps for setting up your VALVEMATE Valve Actuator Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 15: ...Installation 2 Electrical Setup Electrical Setup Electrical connections are marked on the VALVEMATE s rear panel Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg...

Page 16: ...ory package containing the 2 0 amp fuses 3 Install the fuse s into the fuse drawer The fuse drawer for 100 120V accepts one fuse The fuse drawer for 220 240V accepts two fuses 4 Insert the fuse drawer...

Page 17: ...nection Locate the appropriate power cord for your line voltage Discard the other power cord Use the power cord to connect the VALVEMATE to an AC power source Artisan Technology Group Quality Instrume...

Page 18: ...rolling the VALVEMATE via the input contacts send pulse signals These signals momentarily close activate and open deactivate a contact The duration of the pulse must be at least 0 1 second Items you w...

Page 19: ...correct orientation of the terminal block connector relative to its receptacle on the rear panel Attach all wires before joining the terminal block connector to its receptacle 3 Insert the terminal b...

Page 20: ...requires a 25 pin male D connector Refer to the back panel of your computer or its documentation to determine which type of D connector it requires RS 232 cables are available from Gilson and your lo...

Page 21: ...o link the VALVEMATE to other GSIOC modules Refer to the diagram below Use the female connector located individually at one end of the cable to connect the GSIOC cable to another GSIOC cable in the sy...

Page 22: ...ake sure the tubing presses against the bottom of the port before you tighten the nut Hamilton valve A Hamilton valve does not include fittings The fittings you will use depend on the OD of the tubing...

Page 23: ...ore information about the GSIOC At the factory Gilson set the VALVEMATE s unit ID to 35 There is no need to change this number unless it conflicts with another unit s ID number For example if you had...

Page 24: ...the VALVEMATE is controlled via the RS 232 change the baud rate to the value set for the controlling device Valid baud rates are 9600 and 19200 Do not use External If the VALVEMATE is controlled via...

Page 25: ...the VALVEMATE If the valve adapter is not installed also locate the following 9 64 Allen or hex wrench supplied with a Rheodyne high pressure valve or the Gilson manufactured adapter wrench supplied...

Page 26: ...e selector knob is installed remove the knob by removing the screw that secures the knob to the valve 2 Use an adjustable wrench to align the valve shaft s flat edge with port 4 Rheodyne 7000 7010 703...

Page 27: ...n the valve shaft and rotate until the flat edge on the shaft is aligned with port 1 Rheodyne 7610 valve To place the valve in its home position 1 If the selector knob is installed remove the knob by...

Page 28: ...ence install the valve adapter When joining the adapter to the valve ensure that the valve adapter s groove faces upward the valve s flat edge faces the left and is perpendicular to the valve adapter...

Page 29: ...ve adapter s flat edge face away from the valve 4 To attach the valve and its adapter insert and tighten the two flat head screws supplied with the adapter Rheodyne 7000 7010 7030 7040 7710 9010 9030...

Page 30: ...er s flat edge face away from the valve 4 To secure the valve and adapter insert and tighten the two socket head screws Rheodyne 7610 valve To install the valve adapter 1 Refer to the diagram to insta...

Page 31: ...ng screws Just loosen the screws until the valve can be removed Do not over loosen the screws Selecting the Replacement Valve in the VALVEMATE Software Before inserting the replacement valve 1 Press M...

Page 32: ...accessed via the two access holes in the right side of the VALVEMATE 2 Take turns tightening the internal coupling screws via the access holes in the right side of the VALVEMATE 3 Insert the handle o...

Page 33: ...nse additional liquid into the top left side port 6 Verify that the liquid exits the bottom left side port Hamilton 86913 86915 or 86918 valve To verify that the valve is properly installed 1 Fill a s...

Page 34: ...he center port 7 Verify that the liquid exits port 2 Rheodyne 5031 5032 7030 or 9030 valve To verify that the valve is properly installed 1 If the valve has a loop remove the loop 2 Fill a syringe 3 C...

Page 35: ...d into the port 4 Verify that the liquid exits port 3 If it does not remove the valve orient the valve in its home position and install the valve again Refer to pages 2 13 and 2 14 Then repeat steps 1...

Page 36: ...ews accessed via the holes on the right side of the VALVEMATE If this occurs 1 Remove the valve if it is installed 2 ENSURE THAT ALL TOOLS HAVE BEEN REMOVED FROM THE VALVEMATE 3 Turn power on to the V...

Page 37: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 38: ...on Serial Input Output Channel GSIOC Note If a Rheodyne 5000 series valve is installed in the VALVEMATE check and if necessary tighten the screws located on the front of the valve before each run Thes...

Page 39: ...r information 2 REMOTE This indicator illuminates when the VALVEMATE is being externally controlled via its RS 232 or GSIOC port 3 POWER This indicator illuminates when the rear panel MAINS switch is...

Page 40: ...osition In unit ID mode use these keys to select a unit ID from 30 to 39 The default is 35 You need to change the VALVEMATE s unit ID if it and another VALVEMATE are being externally controlled via th...

Page 41: ...ssage indicating that the non volatile memory is being checked VALVEMATE V1 11 Checking NV RAM If the VALVEMATE passes the software check you see the following message VALVEMATE V1 11 System OK Next y...

Page 42: ...rns it in a clockwise direction For a 2 position valve pressing either arrow key turns the valve to its other position Continue to press an arrow key until the desired number is displayed after Positi...

Page 43: ...ding contact signals These examples assume that the contact device s output 2 is connected to the VALVEMATE s CCW input Example 1 If your contact device can issue pulse signals use the following examp...

Page 44: ...ld require maintenance please refer to the instruction sheet supplied with the valve Note If a Rheodyne 5000 series valve is installed in the VALVEMATE check and if necessary tighten the screws locate...

Page 45: ...3 Insert a small screwdriver into the notch located below the fuse drawer 4 Twist the screwdriver to open and remove the fuse drawer The fuse drawer contains one 2 0A T Slo Blo fuse 5 x 20 mm size fo...

Page 46: ...the VALVEMATE refer to the following pages If you cannot solve or isolate the problem contact Gilson or your local Gilson representative See Before Calling Us on page 5 5 Artisan Technology Group Qua...

Page 47: ...sheet supplied with the valve 12 Homing Error The VALVEMATE cannot home the valve Ensure that the appropriate valve is selected in the VALVEMATE software Check that the valve is secure within the coup...

Page 48: ...TE Remove the valve and use an adjustable wrench to place it in home position and then re install the valve refer to Section 2 Input functions not operating Make sure wire connections into the termina...

Page 49: ...apter is attached refer to Section 2 The valve may be incorrectly plumbed refer to the instruction sheet supplied with the valve Fluid may not be reaching the valve if connected to a pumping system lo...

Page 50: ...connections valve installed in the VALVEMATE list of other electrical connections in the room Warranty Repair Units covered under warranty will be repaired and returned to you at no charge If you hav...

Page 51: ...y is assumed by Gilson for damage caused by improperly packaged instruments Indicate the authorization on the carton and on the packing slip Always insure for the replacement value of the unit Include...

Page 52: ...0 2 Position 6 Port 4 Way Valve Assembly with attached mounting adapter and fittings 33035405 Rheodyne 7060 6 Position Selection Valve Assembly with attached mounting adapter and fittings 33035406 Rhe...

Page 53: ...1 2 Position 6 Port 3 Way Valve Assembly with attached mounting adapter and fittings 33035414 Rheodyne 5032 2 Position 6 Port 3 Way Valve Assembly with attached mounting adapter and fittings 33035415...

Page 54: ...ngs 4967610 Rheodyne 7610 2 Position 10 Port Switching Valve Assembly and fittings Note If you are ordering the valve assembly directly from Rheodyne you must specify that you want a 7610 401 valve as...

Page 55: ...te on page A 5 4973H66 Hamilton 86915 HVXD 6 5 6 Position Selection Valve Assembly without fittings see Note on page A 5 4973H88 Hamilton 86918 HVXD 8 5 8 Position Selection Valve Assembly without fit...

Page 56: ...ss steel tubing 0 8 mm 0 03 ID x 1 5 mm 1 16 OD 50 cm 19 5 long 49933609 Stainless steel tubing 0 8 mm 0 03 ID x 1 5 mm 1 16 OD 60 cm 23 4 long 49933809 Stainless steel tubing 0 8 mm 0 03 ID x 1 5 mm...

Page 57: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 58: ...B 1 B Valve Flow Path Diagrams Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 59: ...Appendix B Valve Flow Path Diagrams Rheodyne Valves The following graphics are provided courtesy of Rheodyne L P Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg...

Page 60: ...B 3 Appendix B Valve Flow Path Diagrams Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 61: ...B 4 Appendix B Valve Flow Path Diagrams Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 62: ...B 5 Appendix B Valve Flow Path Diagrams Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 63: ...B 6 Appendix B Valve Flow Path Diagrams Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 64: ...pendix B Valve Flow Path Diagrams HamiltonValves The following graphics are provided courtesy of Hamilton Company Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisant...

Page 65: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 66: ...it ID to another number Refer to Checking the VALVEMATE s Configuration in Section 2 for information on how to change the VALVEMATE s unit ID and the baud rate setting To control one or more VALVEMATE...

Page 67: ...equest status information from the VALVEMATE These commands are executed immediately temporarily interrupting other GSIOC commands in progress and return the requested information When issuing GSIOC c...

Page 68: ...rror 10 NV RAM checksum not matched 11 Missing motor step 12 Home position detection error 14 Illegal position command H B Moves valve to home position I I Reads status of input contacts Returns ab wh...

Page 69: ...the VALVEMATE or a valve has been in use Nx B Sets the counter that tracks the number of hours that either the VALVEMATE or a valve has been in use Replace x with a number from 0 to 99999 For example...

Page 70: ...t buffered Wn x x command If a buffered Wn x x command has not been sent the immediate W command returns the upper line If the immediate command is sent again it returns the lower line Wn x x B Discon...

Page 71: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 72: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: