5. Install the rocker 

Take  out  the  rocker  and  hang  it  onto  the  upright  post,  stick  the  sliding 

cover  into  the  hole  on  the  top  of  the  rocker,  then  install  the  horizontal 

sliding rod and tighten it with the screw. At last, fix the rocker locker to 

the rocker, make sure that the rocker can run softly and comfortably. 

 

 

 

 

6. Install the bend lamp tube 

Connect the power line in the bend lamp tube with the power line on the 

top  of  the  upright  post  according  to  the  same  color  and  push  the 

connected power line into the upright post, then fix the bend lamp tube to 

the upright post. 

 

 

 

 

 

 

 

 

Summary of Contents for GRT-700

Page 1: ...USER S MANUAL ...

Page 2: ...haracteristics of waterproof dampproof durable and never distort 1 The operating board which can horizontally rotate 90 uses quality environmental protection materials that is high temperature endurable abrasion proof corrosion resistance solid and bearable It can provide power input 2 The design of the hand operated rocker is more human because the rocker can randomly swing up and down left and r...

Page 3: ...gh temperature exposed to sunshine and so on 5 When there is something wrong with the instrument maintain it under the professional s instruction referring to this manual if the circuit needs to be adjusted you must shut off the power and let the professional do it 6 You must change the fuse or lamp according to the original accessories specifications and models in the state of shutting off the po...

Page 4: ...st 3 4 Assembly Process 6 5 Operating Manual 8 6 Possible Failure And Repair 9 7 Electric Principle Map 10 8 Electric System Map 11 This document is supplied according to the exist products We reserve the right to make changes or take back this document anytime without prior notice ...

Page 5: ...ctrical Parameters 1 Input voltage 110V 220V AC 50Hz 60Hz 2 Motor power 55W 24V DC 3 Lamp 16W 110V 220V AC 4 Fuse 5A 250V AC 5 Power without load 1W 6 Pressure test 2KV 7 Working mode S1 8 Main wire 10A 250V 9 Working temperature 30 50 10 Relative humidity less than 90 11 Force of pressing key 1N 5N 12 Cooling mode nature cooling Installation Dimensions 1 Figure size 1150mm 865mm 2030mm 2 Machine ...

Page 6: ... 1 lamp 9 pedal 2 rocker locker 10 horizontal sliding rod 3 rocker 11 projector arm 4 projector tray 12 chair 5 upright post 13 operating board big 6 control panel 14 base 7 tools boxes 8 main box 9 8 7 13 12 11 10 14 2 1 3 4 5 6 ...

Page 7: ...3 Packing List ID Name Qty Figure 1 mainframe 1 2 chair 1 3 rocker 1 4 rocker locker 1 5 sliding cover 1 6 horizontal sliding rod 1 ...

Page 8: ...7 bend lamp tube 1 8 lamp 1 9 projector bracket 1 10 upright post 1 11 power line 1 12 computer connecting line 1 13 reset switch 1 ...

Page 9: ...14 fuse 4 15 wrench of size 17 1 16 hexagon spanners 6 17 decorative ring 1 18 certification instruction manual 1 ...

Page 10: ...ir corresponding holes on the chair connecting plate then fix them with the screws 4 Install the upright post Put the decorative ring around the upright post shaft make the power lines of the projector and lamp go through the holes on the chassis then put the upright post around the shaft in this step you should keep the upright post vertical to the ground Then open the back cover of the chassis t...

Page 11: ...tighten it with the screw At last fix the rocker locker to the rocker make sure that the rocker can run softly and comfortably 6 Install the bend lamp tube Connect the power line in the bend lamp tube with the power line on the top of the upright post according to the same color and push the connected power line into the upright post then fix the bend lamp tube to the upright post ...

Page 12: ...g the eyesight detector onto the horizontal sliding rod tighten the knob then adjust the eyesight detector to a suitable position 10 Place the computer or other related instruments on the operating board connect it to the outlet below the board with the prepared power line 11 Power on to test the wire connection check the keys function of the control panel if the connection is correct fit the back...

Page 13: ...a level You can also use the up down switch on the front of the operating board to do the same operation In addition there is chair up inhibiting device below the operating board to protect the subject s legs 4 When you need it you can rotate the lamp knob on the panel 5 Press the projector key on the control panel and refer to a manual of the projector 6 You should refer to a manual of the eyesig...

Page 14: ...ork The voltage dosen t meet the required Test ang confirm The circuit is connected wrongly Check the circuit and fix the breakdown The projector has no power The projector s power line is short circuit Change the power line The lamp is damaged Change the lamp The lamp has no light The circuit is connected wrongly Check the circuit and fix the breakdown The chair can go down but cann t rise The up...