3.2.3
SDI-12 Commands
Command Summary
aM!
Wind speed/direction (Wind Speed in Metres/Sec, Direction in
Degrees) and 2 digit Status Code.
aM1!
Temperature (Degrees C).
aM2!
Pressure (Hecto-Pascals/Milli-bars).
aM3!
Humidity (%).
aM4!
Dew Point (Degrees C).
aM5!
For future use.
aM6!
For future use.
aM7!
For future use.
aM8!
For future use.
aM9!
Power Supply Voltage (Volts).
aD0!
Request a line of the above data.
Command Details
Command
Description
Response
Example
am!
Command for
Wind speed/direction
(Wind Speed in
Metres/Sec, Direction in
Degrees) and Status
Code.
atttn<CR><LF>
a is unit identifier.
ttt is time in seconds.
n is number of data values.
Measurement command to retrieve a
reading of the maximum time the
MetPak II will take to complete a
measurement, have data ready and the
number of data values.
00053<CR><LF>
0 is unit identifier.
005 is 5 sec. measurement.
3 is the number of data
readings (Speed, Direction
and Status).
0D0!
Retrieve a line of the
above data.
a<dir><mag><status><CR><LF>
0+156+000.46+00<CR><LF>
am1!
Temperature (Degrees C)
atttn<CR><LF>
00051<CR><LF>
0D0!
Retrieve a line of the
above data.
a<temperature><CR><LF>
0+26.2<CR><LF>
am2!
Pressure (Hecto
Pascals/Millibars)
atttn<CR><LF>
00051<CR><LF>
0D0!
Retrieve a line of the
above data.
a<pressure><CR><LF>
0+1019.1<CR><LF>
am3!
Humidity (%)
atttn<CR><LF>
00051<CR><LF>
0D0!
Retrieve a line of the
above data.
a<humidity><CR><LF>
0+37.7<CR><LF>
am4!
Dewpoint (Degrees C)
atttn<CR><LF>
00051<CR><LF>
0D0!
Retrieve a line of the
above data.
a<dewpoint><CR><LF>
0+10.7<CR><LF>
am9!
Power Voltage (Volts)
atttn<CR><LF>
00051<CR><LF>
0D0!
Retrieve a line of the
above data.
a<voltage><CR><LF>
0+12.0<CR><LF>