Operation
MetPak II User Manual
Last Change
©
Gill Instruments Ltd
20 August, 2010
Page 27
Command
Parameters
Description and examples
SERIAL
Used to report the MetPak II serial number.
e.g. 00000008
SWVER
Returns the MetPak II Firmware version e.g. SWVER = 2436 V1.00
UNITS
WIND
PRESS
TEMP
DEWPOINT
RH
Valid values are dependent on sensor type. A UNITS command with no
parameter shall display a line of test showing the selected units of the
current output string. Changes the output units for an individual sensor.
UNITS <no parameter> - returns the current value, e.g.
e.g. UNITS = -,DEG,MS,HPA,%,C,C,V,-,-
UNITS WIND MS - selects metres/second for the wind reading.
UNITS PRESS HPA - Selects hectoPascals for the pressure reading.
UNITS TEMP C - selects centigrade for temperature reading.
UNITS DEWPOINT C - selects centigrade for dewpoint reading.
UNITS RH % - selects percentage for relative humidity
See Table 10 for a list of unit abbreviations.
Table 10
Abbreviations used in UNIT configuration command
UNITS
measurement
parameter
Unit
Abbreviation
Metres per Second
MS
Nautical Miles per Hour
KNOTS
Miles per Hour
MPH
Kilometres per Hour
KPH
WIND
Feet per Minute
FPM
Celsius
C
Fahrenheight
F
TEMP
and
DEWPOINT
Kelvin
K
HectoPascals
HPA
MilliBars
MB
Inches of Mercury
INHG
PRESS
Millimetres of Mercury
MMHG
RH
Relative Humidity
%
3.2.2
Configuring MetPak II for SDI-12
To configure a MetPak II unit for SDI-12:
1.
Place the MetPak II into SETUP MODE as described on page 24.
2.
Type
COMMS SDI12
and press Enter. Until the unit is restarted, the
COMMS setting will remain unchanged.
3.
Shut down the MetPak II unit.
4.
Change the hardware connections for SDI-12.
5.
Restart the unit and restart the MetPak unit.