Model: PO-VH & OVH-10
Installation
2.
Installation
1.
Do not obstruct the exhaust air outlet. Maintain a minimum clearance of 12 inches (304.8mm)
between the Hood air outlet (located on top of the unit) and the ceiling or any obstruction,
18”
(457.2mm) clearance is recommended.
This section provides a summary of procedures necessary to install your new PO-VH or OVH-10. Before
installing or servicing this equipment, please read the contents of this manual thoroughly. Following these
procedures will help ensure a safe and proper installation.
2-01. Location
NOTE:
•
The decibel level of the hood when operating is approximately 65 dB’s.
•
DO NOT MODIFY, ALTER OR ADD ATTACHMENTS TO THIS EQUIPMENT
!
CAUTION
NOTE:
•
An HVAC specialist may be required for installations to confirm proper air
exchange and the heat load capabilities of the on site AC system.
•
Exhaust ventilation is recommended for areas in which recirculating hoods are used. We recommend
50 CFM per lineal ft. of hood.
•
This amount could vary based on local codes and the site specific installation requirements.
Summary of Contents for OVH-10
Page 3: ......
Page 11: ...2 Model PO VH OVH 10 Introduction 1 4 Specifications 1 4 1 Overall Dimensions for PO VH UCM ...
Page 12: ...3 Model PO VH OVH 10 Introduction 1 4 2 Overall Dimensions for OVH 10 UCM ...
Page 27: ...Model PO VH OVH 10 Overview 18 3 01 Control Panel 6 5 4 3 2 1 Interlocking Start ILS Only ...
Page 33: ...24 Model PO VH OVH 10 Overview Notes ...
Page 45: ...Notes Operation Filter Maintenance Model PO VH OVH 10 36 ...
Page 53: ...44 Model PO VH OVH 10 Parts List 7 3 Filter Compartment PO VH Not shown UV Only 2 4 3 3 1 5 ...
Page 57: ...48 Model PO VH OVH 10 Parts List 7 5 Filter Compartment OVH 10 Not shown UV Only 2 4 3 3 1 5 ...
Page 59: ...50 Model PO VH OVH 10 Parts List Notes ...