![GILES OVH-10-FB Operation & Service Manual Download Page 36](http://html.mh-extra.com/html/giles/ovh-10-fb/ovh-10-fb_operation-and-service-manual_2227257036.webp)
26
Model: OVH-10-FB & 11-FB
Operation & Filter Maintenance
To maintain peak performance, the EAC Filter Cell
must
be cleaned daily, or as otherwise recommended. Failure to
do so will eventually lead to filter system failure and will reduce Charcoal Filter life, leading to increased operating
costs. Follow the procedure below for effective cleaning.
The EAC cell is NOT designed to withstand washing in commercial dishwashers.
1.
Add
64 ozs.
of a mild degreaser concentrate, such as
Simple Green
or
Clear Magic
, to the provided Soak Tank
... add water to the fill line
etched on the inside of the Tank’s back and mix thoroughly.
2.
Grasp the Contact Plate
and carefully lower the EAC Cell
into
the mixed degreasing solution.
3.
Allow the Cell to soak for 30 minutes. After that time, hold cell by the
Contact Plate
, lift it and agitate up and down in the solution several
times to dislodge grease residue.
4.
Carefully remove the Cell from the Soak Tank and rinse thoroughly in a
sink, using hot water spray.
5.
Stand cell on end on a drain board with Contact Plate up and allow it to air
dry overnight.
Must be completely dry before use.
6. Inspect cell for broken wires or bent fins. Broken wires need to be
replaced promptly. If needed, bent fins may be gently straightened by
hand.
2
2
1
3
1
2
3
•
Avoid bending the collection fins or breaking the fine ionizer wires on the Cell. This will
prevent the collecting cell from performing properly and potentially void the warranty.
•
Never place a wet EAC Cell into the Hood for operation ... it must be completely dry.
!
CAUTION
4-03.2.
EAC Filter Cell Cleaning
NEVER attempt to clean and re-use the Charcoal Filter. Damage to the unit could result.
The Charcoal Filter cannot be cleaned ... it is a one-use consumable item to be replaced
ONLY
with a new filter
.
Replacement frequency is variable depending on type of cooking activity and amount of usage. Typically, the
Charcoal Filter will require replacement between 30 and 90 days. Replacement Part No. 94486.
It is advised
that the installation date be recorded in the space provided on the new filter label.
Failure to use Giles OEM parts and OEM replacement Filters may void the factory warranty.
4-03.3.
Charcoal Filter Maintenance
With proper care, cleaning, and handling, the EAC cell is designed to provide years of service. It is
important that it be cleaned as described above.
The degreasing solution can
be used for up to 30 days, or
until a greasy film is visible on
top of the liquid. Always ensure
that the solution completely
covers the cell ... add water if
needed.
CAUTION
Summary of Contents for OVH-10-FB
Page 2: ......
Page 4: ......
Page 10: ...viii Model OVH 10 FB OVH 11 FB Safety ...
Page 20: ...10 Model OVH 10 FB 11 FB Installation 2 04 2 Hood Appliance Wiring Configurations ...
Page 22: ...12 Model OVH 10 FB 11 FB Overview ...
Page 24: ...Overview Model OVH 10 FB OVH 11 FB 14 3 01 Control Panel 2 1 ILS Only Not Shown 6 5 3 4 8 7 ...
Page 26: ...16 Model OVH 10 FB Overview 3 02 Hood Front Filter Chamber 1 4 3 2 5 6 ...
Page 30: ...20 Model OVH 10 FB OVH 11 FB Overview NOTES ...
Page 38: ...NOTES Operation Filter Maintenance Model OVH 10 FB 11 FB 28 ...
Page 42: ...Notes Hood Cleaning Maintenance Model OVH 10 FB 11 FB 32 ...
Page 52: ...42 Parts List NOTES Model OVH 10 FB 11 FB ...
Page 53: ......