background image

24

Model:  OVH-10-FB & 11-FB

Operation & Filter Maintenance

To reinstall Filters, align it with the filter
channel and slide straight into Hood until
filter hits a stop.

Note airflow direction arrows on filters
when reinstalling.

Reinstall Access Door in the reverse
order of removal.  Be sure tab on right
edge of Door properly engages the door
interlock switch.

4-02.3.

Filter Installation - Baffle, EAC Cell & Charcoal

If the Baffle or Charcoal Filter is missing, or not properly positioned, the

Charcoal or Baffle Filter Missing

light 

will illuminate.  The Hood

continues to run, but power to the appliance under the hood is shutdown
until the condition is corrected.  The amber 

Appliance Powered

light will

turn 

OFF

.

1

4-02.4.

Charcoal or Baffle Filter Missing

1

A

I

R

FLO

W

AI

R

FLO

W

4-02.5.

EAC Filter Cell Missing

If the EAC Filter Cell is missing or not properly positioned, all 3 EAC Status

lights 

will illuminate.  After approximately 2 minutes, an intermittent

tone (beeping) alarm will sound and within a short time, power to the

appliance under the hood is shutdown until the condition is corrected.  The

Hood continues to run, but the amber 

Appliance Powered

light will turn

OFF.

Other conditions can also cause this issue, see Section 4-02.6 for

further information.

2

2

Summary of Contents for OVH-10-FB

Page 1: ... 2750 Gunter Park Drive West Montgomery AL 36109 USA Phone 334 272 1457 Fax 334 239 4117 www gfse com Toll Free 800 554 4537 USA Canada Only OVH 10 FB OVH 11 FB Operations Service Manual Form 65873 B Rel Jun 2013 Rev B Aug 2016 Model OVH 11 FB with Removeable Front Side Skirts ...

Page 2: ......

Page 3: ...y authorized serv ice representatives to repair recondition replace or inspect units of its manufacture with such labor being rendered without cost to owner for 24 months from the date of installation Otherwise serv ice including labor and transportation charges or other expenses in connection with the removal or installation of any part or parts supplied under this Limited Warranty are specified ...

Page 4: ......

Page 5: ... 04 2 Regulatory Listings 3 1 04 3 Hood Weight 3 2 Installation 4 2 01 Unpacking 4 2 02 Location 5 2 02 1 Clearance to Combustibles 6 2 03 Cooking Appliance Limitations Clearances 7 2 04 Electrical Requirements 8 2 04 1 Electrical Connections 9 2 04 2 Hood Appliance Wiring Configurations 10 2 04 3 Installation with Plug Receptacle Option 11 3 Overview 13 3 01 Control Panel 14 3 02 Hood Front Filte...

Page 6: ...ctrical Components OVH 11 FB 38 7 04 Hood Front Filter Compartment 40 4 Operation Filter Maintenance 21 4 01 Hood Operation 21 4 01 1 Starting the Hood Regular 21 4 01 2 Starting the Hood ILS Model 21 4 02 Hood Filter System 22 4 02 1 Filter Table 22 4 02 2 Filter Removal Baffle EAC Charcoal 23 4 02 3 Filter Installation Baffle EAC Charcoal 24 4 02 4 Charcoal or Baffle Filter Missing 24 4 02 5 EAC...

Page 7: ... situation which if not avoided will result in severe injury or even death Use of this is limited to the most extreme situations DANGER Indicates a potentially hazardous situation which if not avoided may result in serious injury or even death WARNING Indicates a potentially hazardous situation which if not avoided may result in minor to moderate injury Also alerts against unsafe practices CAUTION...

Page 8: ...with these WARNING notices could result in serious injury or even death and equipment or property damage WARNING DO NOT block or obstruct the discharge area around the exhaust air diverter on top of the Hood Doing so may restrict airflow through the Hood and significantly reduce capture performance It is recommended to maintain a sufficient clearance between the top of air diverter and the ceiling...

Page 9: ...freight company It is generally the customer s responsibility to negotiate freight damage claims As an aid for electricians and installers an electrical wiring diagram is provided with the unit Refer to the wiring diagram during installation or while servicing Comply with all appropriate state and or local heath regulations regarding cleaning and sanitation of foodservice equipment Giles recommend...

Page 10: ...viii Model OVH 10 FB OVH 11 FB Safety ...

Page 11: ...dicates that the Baffle Filter and or the Charcoal Filter is missing or not properly installed Charcoal or Baffle Filter Clogged light indicates that the Baffle Filter and or the Charcoal Filter is possibly clogged and restricting airflow through the Hood to a level below the minimum required Filters Baffle Filter captures and collects the largest particulate entrained in the air stream Electronic...

Page 12: ...2 Model OVH 10 FB OVH 11 FB Introduction 1 04 Specifications 1 04 1 Overall Dimensions Dimension OVH 10 FB OVH 11 FB A 39 7 8 1012 8 42 3 16 1071 5 B 30 5 16 769 9 34 13 16 844 4 A B Inches mm ...

Page 13: ... Model OVH 10 FB 11 FB Introduction 1 04 2 Regulatory Listings 1 04 3 Hood Weight Hood Crated Weight Uncrated Weight OVH 10 FB 221 lbs 100 2 kg 130 lbs 58 9 kg OVH 11 FB 235 lbs 106 6 kg 165 lbs 74 8 kg ...

Page 14: ...id and set aside 4 The unit is extremely heavy Using suitable lifting equipment or adequate manpower lift the unit and remove it from the shipping skid See Section 1 4 3 Hood Weights 5 Properly dispose of all shipping materials 2 01 Unpacking The unit is very heavy Exercise due caution when handling to avoid personal injury or damage to the equipment Exercise care when removing the wooden framing ...

Page 15: ...des and site specific situations The Hood and it s companion appliance must be positioned in a suitable indoor location on a level floor and placed as near as possible to the power source wall receptacle disconnect box etc which will be supplying the Hood and appliance power Consider that the sound level of the Hood while operating is approximately 65 dB DO NOT block or obstruct the discharge area...

Page 16: ...6 Model OVH 10 FB 11 FB Installation 2 02 1 Clearance to Combustibles Dimension OVH 10 FB OVH 11 FB A 39 7 8 1012 8 42 3 16 1071 5 B 30 5 16 769 9 34 13 16 844 4 A B ...

Page 17: ...pplied by a circuit separate from the Hood which has a separate contactor that is interlocked through the Hood s internal contactor coil B C Dimension OVH 10 FB OVH 11 FB B 39 7 8 1012 8 42 3 16 1071 5 C 30 5 16 769 9 34 13 16 844 4 APPLIANCE RESTRICTIONS APPLIANCE TYPE MAX ELECTRIC INPUT kW WATTS A MAX INCH mm OVENS 11 5 11 500 30 762 ROTISSERIES 6 2 6 200 6 152 A ...

Page 18: ...d result in serious injury or even death damage to equipment or property and void the warranty WARNING Power Rating for Hood Appliance on Same 208 240V Circuit Voltage Hz Phase Field Provided Appliance Power Amps Hood Power Amps Branch Circuit Breaker Amps if Connecting Hood Appliance on Same Circuit OVH 10 FB OVH 11 FB 208 240 60 1 or 3 0 10 5 2 1 1 8 4 4 3 8 15 10 6 14 5 2 1 1 8 4 4 3 8 20 14 6 ...

Page 19: ...d by customer 4 Connect Hood and Appliance wiring to Hood terminal blocks Adhere to all local electrical code Several different wiring configuration options are possible depending on specific installation situations See Section 2 04 2 for specific details of these options If you have questions call Giles Technical Services 800 554 4537 for assistance 5 Replace all Panels and Covers 6 Turn main bre...

Page 20: ...10 Model OVH 10 FB 11 FB Installation 2 04 2 Hood Appliance Wiring Configurations ...

Page 21: ...ance route the appliance s power cord to the rear of the unit Here again if the appliance plug prong configuration does not match that of the Hood s receptacle a qualified electrician should be consulted 6 Connect the appliance plug securely into the Hood receptacle 7 Connect the Hood power plug securely into the facility wall receptacle 8 Both Hood and appliance are ready for use Available Plug a...

Page 22: ...12 Model OVH 10 FB 11 FB Overview ...

Page 23: ...verview of the components functions and accessories of the OVH 10 FB OVH 11 FB Ventless Hood Please review this section carefully before attempting to operate the unit 3 Overview Hood Exhaust Air Diverter Control Panel Filter Access Door Removeable Side Skirts Model OVH 11 FB ...

Page 24: ...Overview Model OVH 10 FB OVH 11 FB 14 3 01 Control Panel 2 1 ILS Only Not Shown 6 5 3 4 8 7 ...

Page 25: ...ioning normally 6 WASH CHECK Indicator EAC Status The WASH CHECK indicator lights will illuminate to signal an abnormal condition with the EAC cell Typically this results from the cell becoming excessively dirty but it can also indicate a damaged cell faulty wiring or component poor electrical contact etc When these lights are on the EAC is not effectively cleaning the air Within 2 minutes an alar...

Page 26: ...16 Model OVH 10 FB Overview 3 02 Hood Front Filter Chamber 1 4 3 2 5 6 ...

Page 27: ...Filter helps to eliminate cooking aromas from the discharged air This Filter should be replaced every 30 to 90 days depending on cooking activity and volume This filter is a single use consumable item NEVER attempt to clean and re use the Charcoal Filter replace with new filter 5 Exhaust Air Diverter The Exhaust Diverter directs filtered exhaust air to the rear and sides There is no minimum cleara...

Page 28: ...er Function Baffle Filter P N 45096 Captures large grease particulate removing it from the airstream EAC Filter Cell P N 22360 Electrostatically removes fine grease particulate from the airstream Charcoal Fiber Filter P N 94486 Helps to remove cooking aromas and odors from the discharged air ...

Page 29: ...19 Model OVH 10 FB 11 FB Overview 3 03 Accessories Standard Part Description Part Number Function EAC Soak Tank P N 39327 Used for soaking and cleaning the EAC Filter Cell ...

Page 30: ...20 Model OVH 10 FB OVH 11 FB Overview NOTES ...

Page 31: ... Sections of this Manual 4 3 1 Confirm that all Filters are in place and properly seated before attempting to operate the hood The Filter Access Door must be in place and secure NOTE The hood will NOT start if the Filter Access Door is not installed or not properly positioned 4 Operation Filter Maintenance 4 01 Hood Operation 1 The following section describes Hood operation Filter maintenance and ...

Page 32: ... Section 4 02 03 Charcoal Filter Replace periodically 30 90 days depending on cooking activity and volume Section 4 02 02 Never clean Replace with New Only Section 4 03 03 Section 4 02 03 The OVH 10 FB and OVH 11 FB Hood Filter System consist of three 3 stages The following section describes filter maintenance and cleaning procedures necessary to keep the air cleaning system operating at peak perf...

Page 33: ...1 Place Power Switch in OFF position 3 To remove Filters simply slide the desired Filter straight out of the Filter Chamber track 2 Remove Filter Access Door Grasp Handle lift and slide Door straight up so that bottom edge will clear flange Pull bottom edge toward you then pull Door downward to remove ...

Page 34: ...will illuminate The Hood continues to run but power to the appliance under the hood is shutdown until the condition is corrected The amber Appliance Powered light will turn OFF 1 4 02 4 Charcoal or Baffle Filter Missing 1 A IRFLOW AIRFLOW 4 02 5 EAC Filter Cell Missing If the EAC Filter Cell is missing or not properly positioned all 3 EAC Status lights will illuminate After approximately 2 minutes...

Page 35: ...d When the WASH CHECK lights are ON the cell is too dirty to function and power to the appliance is about to be shutdown ON Light is ON to indicate the EAC Filter Cell is in place powered and operating properly to clean the airstream through the Hood This is the only status light illuminated during normal operation WASH CHECK When these 2 lights are illuminated an abnormal condition exists with th...

Page 36: ... wires need to be replaced promptly If needed bent fins may be gently straightened by hand 2 2 1 3 1 2 3 Avoid bending the collection fins or breaking the fine ionizer wires on the Cell This will prevent the collecting cell from performing properly and potentially void the warranty Never place a wet EAC Cell into the Hood for operation it must be completely dry CAUTION 4 03 2 EAC Filter Cell Clean...

Page 37: ...ce Filter 4 02 2 4 02 3 Continuous tone Alarm sounds Charcoal or Baffle Filter Clogged lamp illuminates and power to the appliance is shutdown Appliance Powered light is OFF Baffle Filter dirty or otherwise clogged Remove and clean Filter 4 02 2 4 02 3 4 03 1 Intermittent beeping tone Check Wash lights are illuminated alarm sounds and after approx 2 minutes power to the appliance is shutdown Appli...

Page 38: ...NOTES Operation Filter Maintenance Model OVH 10 FB 11 FB 28 ...

Page 39: ... Place power switch in the OFF position remove the EAC Filter Cell see Section 4 02 2 Replace Access Door and turn ON power All three EAC status lights should illuminate and after approximately 2 minutes an intermittent tone beeping alarm should sound The Appliance Powered light should turn OFF Confirm that the under hood appliance cannot operated Turn power switch OFF and reinstall EAC Filter Cel...

Page 40: ... dry or wipe dry with clean dry cloth 7 Clean filters as needed and replace in Hood 8 Restore supply power to Hood 5 02 Hood Cleaning DO NOT wash down hood with water from a spray hose DO NOT steam clean or use any type pressure washer DO NOT use products containing chlorine or other caustic chemicals DO NOT use abrasive products steel wool or scouring pads CAUTION 5 02 1 Weekly Cleaning As a mini...

Page 41: ... 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 1 2 3 4 5 1...

Page 42: ...Notes Hood Cleaning Maintenance Model OVH 10 FB 11 FB 32 ...

Page 43: ...st 5 seconds Press hold down PUSH TO START button for 5 secs c Power Switch is faulty Replace Power Switch d Improper supply voltage Connect unit to proper electrical supply e Not properly connected to power source Confirm connections correct f Blown fuse or tripped circuit breaker Check fuse in hood and main breaker panel Charcoal or Baffle Filter Missing light illuminated at Initial Start up a B...

Page 44: ...haust is clear and area around diverter is clear c Vacuum Switch clogged filter sensor is out of adjustment Have vacuum switch adjusted d Kinked or blocked vacuum line Remove vacuum line kinks or blockage e Fan running slow or blades are loaded with grease film Check voltage and inspect blower clean if needed Cooking appliance will not operate Hood Power light ON WASH CHECK lights ON APPLIANCE POW...

Page 45: ...e highest quality service and assistance possible To help us accomplish this please have the following information readily available when calling along with the nature of the problem you are encountering This information is recorded on a Serial Plate or Label attached to the unit Record information here for quick future reference Model Name ______________________________________ Serial Number ____...

Page 46: ...36 Model OVH 10 FB 11 FB Parts List 7 02 Rear Electrical Components OVH 10 FB 8 2 1 10 3 6 4 7 14 12 15 16 13 18 ILS Model Only Not Seen 17 9 5 17 11 REAR PANEL SIDE PANEL ...

Page 47: ...UM SWITCH DUNGS 0 4 4 0 WC 6 23782 1 SONALERT CONTINUOUS TONE 250V 7 22950 1 SONALERT INTERMITTENT TONE 250V 8 21950 2 FUSE HOLDER 300V 15A SC 0 15 9 21875 2 FUSE 6 AMP SC 6 10 20312 1 RELAY BASE PLUG IN DIN MOUNT 11 20318 1 RELAY 240 VAC 10A ELECTRO MECH 12 20320 1 TERMINAL BLOCK GROUND AWG 8 24 13 20319 5 TERMINAL BLOCK 50 AMP AWG 8 24 14 20304 2 TERMINAL BLOCK GROUND 4 12 GA WIRE 15 20303 6 TER...

Page 48: ...38 Model OVH 10 FB 11 FB Parts List 7 03 Rear Electrical Components OVH 11 FB REAR PANEL 9 1 10 4 13 14 18 12 2 3 11 6 17 16 8 5 7 ILS Model Only Not Seen 15 19 SIDE PANEL ...

Page 49: ...A 7 21950 2 FUSE HOLDER 300V 15A SC 0 15 8 21875 2 FUSE 6 AMP SC 6 9 20312 1 RELAY BASE PLUG IN DIN MOUNT 10 20318 1 RELAY 240 VAC 10A ELECTRO MECH 11 20473 1 VACUUM SWITCH DUNGS 0 4 to 4 0 WC 12 20320 1 TERMINAL BLOCK GROUND AWG 8 24 13 20319 5 TERMINAL BLOCK 50 AMP AWG 8 24 14 20304 2 TERMINAL BLOCK GROUND 4 12 GA WIRE 15 20303 6 TERMINAL BLOCK 4 12 GA WIRE 16 91717 1 RAIL DIN 3 7 00 IN 17 22950...

Page 50: ...40 Parts List 7 04 Hood Front Filter Compartment 3 4 6 10 9 12 13 8 14 5 1 2 7 11 ILS Model Only Model OVH 10 FB 11 FB ...

Page 51: ...E A C FILTER 16 5 45096 1 BAFFLE FILTER 12 X 16 STAINLESS STEEL 6 21125 1 CONTACT BOARD E A C 7 24237 2 PLUNGER SWITCH 250V 15A 8 21157 1 LIMIT SWITCH 250V 15A 9 20398 1 INDICATOR LIGHT GREEN 250V 0 5W 10 20399 1 INDICATOR LIGHT AMBER 250V 0 5W 11 20402 2 INDICATOR LIGHT RED 250V 0 5W 12 24209 1 L E D CLUSTER E AC FILTER 13 21190 1 ROCKER SWITCH D P S T 250V 10A 14 23173 1 PUSH BUTTON SWITCH MOMEN...

Page 52: ...42 Parts List NOTES Model OVH 10 FB 11 FB ...

Page 53: ......

Page 54: ...les Enterprises Inc 2750 Gunter Park Drive West Montgomery Al 36109 USA Phone 334 272 1457 Toll Free 800 554 4537 USA Canada Only FAX 334 239 4117 www gfse com Form No 65873 B Rel Jun 2013 Rev B Aug 2016 ...

Reviews: