8
Model: OVH-10-FB & 11-FB
Installation
2-04.
Electrical Requirements
Power Rating for Hood Only, if Appliance is on Separate Circuit & Interlocked Through
Separate Contactor
Model
Voltage
Hz
Phase
Hood Power
(Amps)
Breaker
OVH-10-FB
208 - 240
60
1
2.1 - 1.8
15
OVH-11-FB
208 - 240
60
1
4.4 - 3.8
15
• Consult a qualified electrician to ensure that all electrical specifications have been met and that the unit is
properly grounded.
• Improper installation, adjustment, alteration, service or maintenance could result in serious injury or even death,
damage to equipment or property, and void the warranty.
!
WARNING
Power Rating for Hood & Appliance** on Same 208-240V Circuit
Voltage
Hz
Phase
Field Provided
Appliance Power
(Amps)
Hood Power
(Amps)
Branch Circuit Breaker
(Amps) if Connecting
Hood & Appliance on
Same Circuit
OVH-10-FB
OVH-11-FB
208 - 240
60
1 or 3
0 - 10.5
2.1 - 1.8
4.4 - 3.8
15
10.6 - 14.5
2.1 - 1.8
4.4 - 3.8
20
14.6 - 22.5
2.1 - 1.8
4.4 - 3.8
30
22.6 - 38.5
2.1 - 1.8
4.4 - 3.8
50
38.6 - 46.5
2.1 - 1.8
4.4 - 3.8
60
46.7 - 50
*
2.1 - 1.8
4.4 - 3.8
70
* Load exceeding 50A must have a circuit separate from the Hood; this circuit must be interlocked through
the Hood contactor coil.
** Appliance provided and rated separately from Hood.
Summary of Contents for OVH-10-FB
Page 2: ......
Page 4: ......
Page 10: ...viii Model OVH 10 FB OVH 11 FB Safety ...
Page 20: ...10 Model OVH 10 FB 11 FB Installation 2 04 2 Hood Appliance Wiring Configurations ...
Page 22: ...12 Model OVH 10 FB 11 FB Overview ...
Page 24: ...Overview Model OVH 10 FB OVH 11 FB 14 3 01 Control Panel 2 1 ILS Only Not Shown 6 5 3 4 8 7 ...
Page 26: ...16 Model OVH 10 FB Overview 3 02 Hood Front Filter Chamber 1 4 3 2 5 6 ...
Page 30: ...20 Model OVH 10 FB OVH 11 FB Overview NOTES ...
Page 38: ...NOTES Operation Filter Maintenance Model OVH 10 FB 11 FB 28 ...
Page 42: ...Notes Hood Cleaning Maintenance Model OVH 10 FB 11 FB 32 ...
Page 52: ...42 Parts List NOTES Model OVH 10 FB 11 FB ...
Page 53: ......