MDE-4288 Encore® USB Printer Kit M04489K00X • October 2004
Page 11
Installing the M04489K004/M04489K005 Kit
16
Connect the USB cable to the CRIND Control Node PCA, connect side 1 cable plug to P3120
(bottom) and side 2 cable plug to P3122 (top) as shown in Figure 9.
Note: If the unit is being updated from a CCN1 to CCN3, these connections can be made after
the CCN3 has been installed.
Figure 9: USB Printer Cable Connection to CRIND Control Node
17
Connect J4 jack of the power cable (side A) to P3502A of the M02774A001 power supply
PCA and J5 jack (side B) to P3502B cable jack J4 to Plug P4 and side 2 cable jack J5 to plug
P5.)
Figure 10: Connection to Power Supply
Side 2 Printer USB
Cable Plug
Side 1 Printer USB
Cable Plug
P3502B - side 2
printer connection
P3502A - side 1
printer connection