- 13 -
Hardware Installation
Soc
ket
Socket
Sec
uri
ty
Security
Power Supply
2 x 1600W redundant PSUs; 80 PLUS Platinum
AC Input:
- 100-240V~/ 12-7A, 50-60Hz
- 200-240V~/ 9.5A, 50-60Hz
DC Input: 240Vdc/8A
DC Output:
- Max 1000W/ 100-240V~
+12V/ 80.5A
+12Vsb/ 3A
- Max 1600W/ 200-240V~ or 240Vdc input
+12V/ 130.4A
+12Vsb/ 3A
Soc
ket
Socket
Sec
uri
ty
Security
System
Management
Aspeed® AST2500 management controller
GIGABYTE Management Console (AMI MegaRAC SP-X) web interface
Dashboard
HTML5 KVM
Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.)
Sensor Reading History Data
FRU Information
SEL Log in Linear Storage / Circular Storage Policy
Hardware Inventory
Fan Profile
System Firewall
Power Consumption
Power Control
LDAP / AD / RADIUS Support
Backup & Restore Configuration
Remote BIOS/BMC/CPLD Update
Event Log Filter
User Management
Media Redirection Settings
PAM Order Settings
SSL Settings
SMTP Settings
Soc
ket
Socket
Sec
uri
ty
Security
Operating
Properties
Operating temperature: 10°C to 35°C
Operating humidity: 8% to 80% (non-condensing)
Non-operating temperature: -40°C to 60°C
Non-operating humidity: 20% to 95% (non-condensing)
Summary of Contents for S472-Z30
Page 1: ...S472 Z30 4U 50 Bay Single Processors Storage Server User Manual Rev 1 0...
Page 14: ...14 Hardware Installation 1 3 System Block Diagram...
Page 56: ...56 BIOS Setup 5 2 4 1 Serial Port 1 2 Configuration...
Page 64: ...64 BIOS Setup 5 2 8 PCI Subsystem Settings...
Page 75: ...75 BIOS Setup 5 2 17 Intel R i350 Ethernet Controller...