- 85 -
Appendix
•
Manually Rebuilding RAID 1 in the Operating System
You can manually rebuild a RAID 1 array without setting the new hard drive as a Spare drive in the RAID setup
utility first. While in the operating system, open the Marvell Storage Utility and login.
Under
Virtual Disk 0
, the
Property
tab displays the
rebuild progress on the right of the
Background Activity
Progress
item, indicating that the RAID volume is being
rebuilt. When completed, the status will display as
Done
.
Step 1:
Under
Virtual Disk 0
, click the
Operation
tab and select
Rebuild
.
Step 2:
The screen will display the new hard drive. Click on the
hard drive to select it and click the
Submit
button to
begin the rebuild.
Step 3:
Make sure you have installed the Marvell RAID driver and Marvell Storage Utility from the motherboard driver
disk. While in the operating system, launch the Marvell Storage Utility from Start\All Programs\Marvell Storage
Utility\Marvell Tray, right-click on the
icon in the notification area, and select
Open MSU
. Then login the
Marvell Storage Utility.
Summary of Contents for GA-X79-UP4
Page 1: ...GA X79 UP4 User s Manual Rev 1001 12ME X79UP4 1001R...
Page 2: ...Motherboard GA X79 UP4 Jul 27 2012 Jul 27 2012 Motherboard GA X79 UP4...
Page 56: ...BIOS Setup 56...
Page 96: ...Appendix 96...
Page 97: ...97 Appendix...
Page 98: ...Appendix 98...