background image

Manual 07504208 

Model 4208 

Page 15 

 

O

peration Manual

 

 

 
 

REGISTER: 8000h 

MODE: 32 bit 

FUNCTION: Control Matrix K1 through 32 

BIT 

FUNCTION 

CONNECTION 

RELAY 

COMMENT 

K1 

J1-56,28 TO J1-48,20 

K1 

Group 1 1x8 

K2 

J1-55,27 TO J1-48,20 

K2 

Group 1 1x8 

K3 

J1-54,26 TO J1-48,20 

K3 

Group 1 1x8 

K4 

J1-53,25 TO J1-48,20 

K4 

Group 1 1x8 

K5 

J1-52,24 TO J1-48,20 

K5 

Group 1 1x8 

K6 

J1-51,23 TO J1-48,20 

K6 

Group 1 1x8 

K7 

J1-50,22 TO J1-48,20 

K7 

Group 1 1x8 

K8 

J1-47,19 TO J1-39,11 

K8 

Group 1 1x8 

K9 

J1-46,18 TO J1-39,11 

K9 

Group 2 1x8 

K10 

J1-45,17 TO J1-39,11 

K10 

Group 2 1x8 

10 

K11 

J1-44,16 TO J1-39,11 

K11 

Group 2 1x8 

11 

K12 

J1-43,15 TO J1-39,11 

K12 

Group 2 1x8 

12 

K13 

J1-42,14 TO J1-39,11 

K13 

Group 2 1x8 

13 

K14 

J1-41,13 TO J1-39,11 

K14 

Group 2 1x8 

14 

K15 

J1-40,12 TO J1-39,11 

K15 

Group 2 1x8 

15 

K16 

J1-39,11 TO J1-39,11 

K16 

Group 2 1x8 

16 

K17 

J1-38,10 TO J1-30,2 

K17 

Group 3 1x8 

17 

K18 

J1-37,9 TO J1-30,2 

K18 

Group 3 1x8 

18 

K19 

J1-36,8 TO J1-30,2 

K19 

Group 3 1x8 

19 

K20 

J1-35,7 TO J1-30,2 

K20 

Group 3 1x8 

20 

K21 

J1-34,6 TO J1-30,2 

K21 

Group 3 1x8 

21 

K22 

J1-33,5 TO J1-30,2 

K22 

Group 3 1x8 

22 

K23 

J1-32,4 TO J1-30,2 

K23 

Group 3 1x8 

23 

K24 

J1-31,3 TO J1-30,2 

K24 

Group 3 1x8 

24 

K25 

J2-56,28 TO J2-48,20 

K25 

Group 4 1x8 

25 

K26 

J2-55,27 TO J2-48,20 

K26 

Group 4 1x8 

26 

K27 

J2-54,26 TO J2-48,20 

K27 

Group 4 1x8 

27 

K28 

J2-53,25 TO J2-48,20 

K28 

Group 4 1x8 

28 

K29 

J2-52,24 TO J2-48,20 

K29 

Group 4 1x8 

29 

K30 

J2-51,23 TO J2-48,20 

K30 

Group 4 1x8 

30 

K31 

J2-50,22 TO J2-48,20 

K31 

Group 4 1x8 

31 

K32 

J2-49,21 TO J2-48,20 

K32 

Group 4 1x8 

 
 

 

 

Summary of Contents for 4208

Page 1: ...Manual 07504208 Model 4208 Page 1 Operation Manual Model 4208 6 1x8 2 wire Multiplexer 90900050 ...

Page 2: ...925 328 4700 On the Internet www gigatronics com Warranty Giga tronics Series 3000 Switching Modules are warranted against defective materials and workmanship for three years from date of shipment or as detailed in the warranty section of this manual Giga tronics will at its option repair or replace products that are proven defective during the warranty period This warranty DOES NOT cover damage r...

Page 3: ...N61010 1 1993 Electrical Safety EN61326 1 1997 EMC Emissions and Immunity Manufacturer s Name Manufacturer s Address Giga tronics Incorporated 4650 Norris Canyon Road San Ramon California 94583 U S A Type of Equipment Model Series Number Switching Module 4208 Declaration of Conformity on file Contact Giga tronics at the following Giga tronics Incorporated 4650 Norris Canyon Road San Ramon Californ...

Page 4: ... are issued as Technical Publication Change Instructions TPCI When you are issued a TPCI do the following 1 Insert the TPCI at the front of the manual binder 2 Remove the pages from the manual binder that are noted in the TPCI 3 Replace the page s removed in the previous step with the corrected page s 4 Record the changes in the table below TPCI Number TPCI Issue Date Date Entered Comments ...

Page 5: ...Manual 07504208 Model 4208 Page 5 Operation Manual Revision History Revision Description of Change Chg Order Approved By A Initial Release 5 98 JL B Updated C Reformatted 3 12 RCW ...

Page 6: ...tions 7 1 1 1 Product Reference 7 1 1 2 Personal Safety Alert 7 1 1 3 Equipment Safety Alert 7 1 1 4 Notes 7 1 1 5 Electrical Safety Precautions 7 Chapter 2 Functional Description 8 2 1 Introduction 8 2 2 General Description 8 Chapter 3 Block Diagram 9 Chapter 4 Specifications 10 Chapter 5 Register Map 11 5 1 Introduction 11 ...

Page 7: ...njury 1 1 3 Equipment Safety Alert CAUTION Indicates a situation which can damage or adversely affect the product or associated equipment 1 1 4 Notes Notes are denoted and used as follows NOTE Highlights or amplifies an essential operating or maintenance procedure practice condition or statement 1 1 5 Electrical Safety Precautions Any servicing instructions are for use by service trained personnel...

Page 8: ...semblies This allows of ease in design of complex switch systems The Series 4000 host VXI module contains sixteen 2 wire analog back plane to allow connections between card assemblies without the need of external cabling This architecture produces a high performance switch system without the usual custom designs or external wiring and integration efforts The interface and mechanical construction o...

Page 9: ...Manual 07504208 Model 4208 Page 9 Operation Manual Chapter 3 Block Diagram Analog Groundplane Typical 1x8 Multiplexer 1 of 6 ...

Page 10: ...s Max Switching Power 60 W Life expectancy Signal 1 0V 0 010A 1 000 000 Contact resistance 0 05 ohm Mechanical Thickness 0 6 inches Width 7 825 inches Length 10 75 inches Weight 1 lbs Connectors Connector Airborn type WTB56PR Environmental Specifications Temperature Operating 0º to 55ºC Storage 40º to 75ºC Relative Humidity Operating 0 to 90 non condensing Storage 0 to 95 non condensing ...

Page 11: ... register map for the relay or relays in the register that is being closed When the data bit is true the relay chosen will be closed The state of the relays in a register can be determined by reading the desired register The data read back represents the value at the coil of the relay This allows verification that the program register has correctly controlled the relay coil The following register ...

Page 12: ...FFCh 06h assigned by Resource Manager Control Bit 3Eh 0 Low true output to enable coil driver IC s 1 When low enables readback of coil state 2 High true EEPROM write enable factory only 3 15 Don t care MSB LSB REG 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 8000h K16 K15 K14 K13 K12 K11 K10 K9 K8 K7 K6 K5 K4 K3 K2 K1 8002h K32 K31 K30 K29 K28 K27 K26 K25 K24 K23 K22 K21 K20 K19 K18 K17 8004h K48 K47 K46...

Page 13: ... J1 30 2 K20 Group 3 1x8 4 K21 J1 34 6 TO J1 30 2 K21 Group 3 1x8 5 K22 J1 33 5 TO J1 30 2 K22 Group 3 1x8 6 K23 J1 32 4 TO J1 30 2 K23 Group 3 1x8 7 K24 J1 31 3 TO J1 30 2 K24 Group 3 1x8 8 K25 J2 56 28 TO J2 48 20 K25 Group 4 1x8 9 K26 J2 55 27 TO J2 48 20 K26 Group 4 1x8 10 K27 J2 54 26 TO J2 48 20 K27 Group 4 1x8 11 K28 J2 53 25 TO J2 48 20 K28 Group 4 1x8 12 K29 J2 52 24 TO J2 48 20 K29 Group...

Page 14: ...27 26 25 24 23 22 21 20 19 18 17 16 8000h K32 K31 K30 K29 K28 K27 K26 K25 K24 K23 K22 K21 K20 K19 K18 K17 LSB REG 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 8000h K16 K15 K14 K13 K12 K11 K10 K9 K8 K7 K6 K5 K4 K3 K2 K1 MSB REG 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 LSB REG 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 8004h K48 K47 K46 K45 K44 K43 K42 K41 K40 K39 K38 K37 K36 K35 K34 K33 ...

Page 15: ...13 J1 42 14 TO J1 39 11 K13 Group 2 1x8 13 K14 J1 41 13 TO J1 39 11 K14 Group 2 1x8 14 K15 J1 40 12 TO J1 39 11 K15 Group 2 1x8 15 K16 J1 39 11 TO J1 39 11 K16 Group 2 1x8 16 K17 J1 38 10 TO J1 30 2 K17 Group 3 1x8 17 K18 J1 37 9 TO J1 30 2 K18 Group 3 1x8 18 K19 J1 36 8 TO J1 30 2 K19 Group 3 1x8 19 K20 J1 35 7 TO J1 30 2 K20 Group 3 1x8 20 K21 J1 34 6 TO J1 30 2 K21 Group 3 1x8 21 K22 J1 33 5 TO...

Page 16: ...15 TO J2 39 11 K37 Group 5 1x8 5 K38 J2 42 14 TO J2 39 11 K38 Group 5 1x8 6 K39 J2 41 13 TO J2 39 11 K39 Group 5 1x8 7 K40 J2 40 12 TO J2 39 11 K40 Group 5 1x8 8 K41 J2 38 10 TO J2 39 11 K41 Group 6 1x8 9 K42 J2 37 9 TO J2 30 2 K42 Group 6 1x8 10 K43 J2 36 8 TO J2 30 2 K43 Group 6 1x8 11 K44 J2 35 7 TO J2 30 2 K44 Group 6 1x8 12 K45 J2 34 6 TO J2 30 2 K45 Group 6 1x8 13 K46 J2 33 5 TO J2 30 2 K46 ...

Page 17: ...e offset address for the Model 4208 is 8000h The total offset of the card is dependent on the location of the card in the host VXI module Series 4000 The offset is x8000h where x is the card location number in hexidecimal refer to the program guide in the Series 4000 host VXI module manual for programing this card ...

Reviews: