- 105 -
BIOS Setup
Parameter
Description
NBIO RAS Common Options
(continued)
System Hub Watchdog Timer
–
Enter a value. This value specifies the timer interval of the
SYSHUB watchdog timer in miliseconds.
SLINK Read Response OK
–
This value specifies whether SLINK read response errors are
converted to an Okay response. When this value is set to TRUE,
read response errors are converted to Okay responses with data
of all FFs. When set to FALSE read response errors are not
converted.
– Options available: Enabled/Disabled. Default option is Disabled.
SLINK Read Response Error Handling
–
This value specifies whether SLINK write response errors are
converted to an Okay response. When this value is set to 0, write
response errors will be logged in the MCA. When set to 1, write
response errors will trigger an MCOMMIT error. When this value is
set to 2, write response errors are converted to Okay responses.
– Options available: Enabled/Trigger MCOMMIT Error/Log Errors in
MCA. Default option is Log Errors in
MCA
.
Log Poison Data from SLINK
–
This value specifies whether poison data propogated from SLINK
will generate a deferred error. When this value is set to TRUE,
deferred errors are enabled. When set to FALSE, errors are not
generated.
– Options available: Enabled/Disabled. Default option is
Disabled
.
PCIe Aer Reporting Mechanism
– This value selects the method of reporting AER errors from PCI
Express. A value of 0 indicates that the hardware will report the
error through MCA. A value of 1 allows OS First handling of the
errors through generation of a system control interrupt (SCI). A
value of 2 provides for Firmware First handling of errors through
generation of a system management interrupt (SMI).
– Options available: OS First/MCA/Auto. Default option is
Auto
.
Edpc Control
– (0) Disabled; (1) Enabled; (3) Auto.
– Options available: Disabled/Enabled/Auto. Default option is
Disabled
.
NBIO Poison Consumption
– Options available: Auto/Enabled/Disabled. Default option is
Auto
.
Summary of Contents for R182-Z90
Page 10: ... 10 This page left intentionally blankThis ...
Page 17: ... 17 Hardware Installation 1 3 System Block Diagram ...
Page 18: ...Hardware Installation 18 ...
Page 26: ...System Appearance 26 This page left intentionally blank ...
Page 32: ...System Hardware Installation 32 CPU 4 5 6 2 3 1 7 ...
Page 40: ...System Hardware Installation 40 5 6 6 ...
Page 46: ...System Hardware Installation 46 R182 Z90 HDD Backplane Board Power Front Panel IO ...
Page 47: ... 47 System Hardware Installation R182 Z90 Front Panel USB ...
Page 48: ...System Hardware Installation 48 3 12 2 Cable Routing for R182 Z91 Onboard SATA NVME ...
Page 50: ...System Hardware Installation 50 R182 Z91 Front Panel IO Front Panel USB ...
Page 52: ...System Hardware Installation 52 R182 Z92 NVMe Card 4 5 NVMe Card 6 7 Top Bo om Bo om Top ...
Page 53: ... 53 System Hardware Installation R182 Z92 NVMe Card 8 9 HDD Backplane Board Signal ...
Page 54: ...System Hardware Installation 54 R182 Z92 HDD Backplane Board Power Front Panel IO ...
Page 55: ... 55 System Hardware Installation R182 Z92 Front Panel USB ...
Page 56: ...System Hardware Installation 56 This page intentionally left blank ...
Page 81: ...BIOS Setup 82 5 2 11 SATA Configuration ...
Page 86: ... 87 BIOS Setup 5 2 16 Intel R I350 Gigabit Network Connection ...