Gibson LP STD LTD Manual v1.0
Page 26
The
setup
menu
allows
access
to
setup
parameters
and
functions
that
control
the
system
behavior.
6.0
Entering
Function
Mode
●
If
Les
Paul
Standard
2010
Limited
is
not
powered
‐
up,
pull
the
MCK
out
and
push
Enter
four
times
briefly,
in
quick
succession.
Each
press
must
be
within
a
half
‐
second
of
the
previous
press.
●
If
Les
Paul
Standard
2010
Limited
is
already
in
a
Bank
other
than
the
Red
Bank,
push
Enter
briefly
in
quick
succession
until
the
Red
Bank
appears.
6.1
Selecting
Setup
Mode
1.
Once
Les
Paul
Standard
2010
Limited
is
in
the
Red
Bank,
rotate
the
MCK
fully
counter
‐
clockwise
to
the
b#
position.
The
Display
Matrix
shows
a
filled
‐
in
circle.
2.
Push
Enter
for
longer
than
one
second;
the
Display
Matrix
shows
a
while
“enter”
symbol
(an
arrow
with
a
right
‐
angle
tail).
3.
Push
Enter
again
for
longer
than
one
second.
The
Display
Matrix
now
shows
a
cyan
enter
symbol
4.
To
change
a
setup
parameter,
you
first
need
to
enter
its
ID
number,
and
then
the
value.
Enter
ID
numbers
sequentially
by
turning
the
MCK
to
the
first
digit
and
pushing
Enter
briefly.
If
the
ID
number
has
two
digits,
rotate
the
MCK
to
the
next
digit
and
push
Enter
briefly.
If
the
ID
number
has
three
digits,
rotate
the
MCK
again
to
the
third
digit,
and
push
Enter
briefly.
When
you
press
Enter
after
selecting
a
digit,
the
number
in
the
Display
Matrix
flashes
red
briefly
for
confirmation.
5.
After
entering
the
ID
number,
turn
the
MCK
fully
counterclockwise
to
the
Enter
position
(cyan
arrow
with
right
‐
angle
tail)
and
push
Enter
briefly.
The
MCK
will
show
the
entered
ID
number,
then
a
question
mark
to
indicate
that
you
can
now
enter
the
parameter
value.
6.
Enter
the
parameter
value
the
same
way
as
you
entered
the
setup
function
ID:
Rotate
the
MCK
to
the
desired
number,
and
push
Enter
briefly
(repeat
for
multi
‐
digit
values).
After
pushing
Enter,
the
number
in
the
Display
Matrix
will
flash
red
for
confirmation.
7.
After
entering
the
value,
turn
the
MCK
fully
counter
‐
clockwise
to
the
Enter
position
(cyan
arrow
with
right
‐
angle
tail)
and
push
Enter
briefly.
The
Display
Matrix
will
show
the
entered
parameter
value,
then
flash
all
outer
LEDs
green
to
confirm
that
the
value
has
been
accepted.
8.
Exit
the
Setup
menu
by
pushing
Enter
for
more
than
one
second.
The
following
set
of
tables
shows
the
various
user
‐
editable
Functions
available
in
Function
Mode,
but
please
notes
the
following
important
points.
Note
1:
The
function's
“clickstream”
shown
in
each
chart
abbreviates
the
MCK
operations
needed
to
edit
the
function.
To
save
space
and
text:
●
It's
assumed
you've
already
completed
steps
1
‐
3
under
Selecting
Setup
Mode.
●
The
§
symbol
means,
“rotate
the
MCK
fully
counter
‐
clockwise
then
push
Enter
briefly.”