Control System
Control System
6
1.1.3 Other operations
FOLLOW ME function
The air conditioner has FOLLOW ME function, when the function is operated, the remote controller will
detect the temperature near the remote controller and compare with the temperature you set
automatically, and control the operation of the air conditioner according to the contrastive result, and
make the temperature near the remote controller reaches the setting temperature. This function is valid
only under COOL, HEAT, AUTO mode and the unit has follow me function. This helps making the room
environment more comfortable and the temperature accurate.
Notes:
To carry on the FOLLOW ME function, please keep the RM02A pointing directly to the indoor unit.
Remote controller cannot be placed near the heat source or low temperature source, otherwise will
affect its temperature gathering precision and then affect the follow me function.
Setting addresses
For the V4 plus system, the RM02A can set the indoor units’ addresses. This function helps the user
assign the address to the indoor units freely. V4 series do not have this function.
Press the Fan speed button and ECO button simultaneously for more than 5 seconds, then the
controller gets into address setting mode.
Press the ON/OFF button to start transmitting signal in the address setting mode. If the transmitting
signal icon has been turned on, then step can be omitted. When working in address setting mode,
press ON/OFF will not turn the controller off.
In the address setting mode, there are 2 main functions:
Querying address: Please point the remote controller to the indoor unit, then press MODE button, the
corresponding indoor unit will display its address.
Setting address: Use the UP and DOWN buttons to choose an address you want. Then point the
remote controller to the indoor unit and then press the FAN button to set the indoor unit’s address.
The corresponding indoor unit will display the new address and record it. After about 4 seconds, this
displaying will fade out and the indoor units turn to normal display mode.
Notes:
the address cannot be repeated in the same system.
After setting all the addresses, users can press the Fan button and ECO button simultaneously again
for 5 seconds to exit the address setting mode.
Keyboard lock
The RM02A allows users to lock the keyboard to prevent mistaken operation or keep the kids from
changing the parameters randomly. Press the
"
MODE
"
and
"
TIMER
"
button simultaneously for 5s, and
then can operate keyboard locking. In the locking mode, all the buttons are ineffective. Pressing the
MODE and TIMER button for a period and the