IMPORTANT SAFEGUARDS 

• Use this appliance only as described in this instruction manual. As with all electrical equip­

ment,  whilst the instructions aim to cover as many eventualities as possible,  caution and

common sense should be applied when operating and installing this appliance.

• This appliance is designed far home air conditioning and must not be used far other pur­

poses

• lt is dangerous to modify or alter the characteristics of the appliance in any way.

• The appliance must be installed in confarmity with national legislation regulating electrical

equipment and installations.

• lf the appliance requires repair, contact a Service Centre authorised by the manufacturer

only.  Repairs carried out by unauthorised personnel may be dangerous.

• This appliance must be used exclusively by adults.

• The appliance must be connected to an efficient earth system.  Have your electrical circuit

checked by a qualified electrician.

• Do not use extension cables.

Befare cleaning or maintenance, always unplug the appliance from the mains socket.

• Never unplug the appliance by pulling on the power cable.

• Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sour­

ces of heat

• Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or pres-

surised containers (eg aerosol cans).

• Do not rest heavy or hot objects on top of the appliance.

• Clean the air filter at least once a week.

• Avoid using heating appliances near the air conditioner.

• Always transport the appliance upright or resting on one side.  Befare moving the applian­

ce, empty the interna! circuit completely of water. After moving the appliance, wait at least

1  hour befare starting it.

• When putting the appliance away, do not cover with plastic bags.

• The materials used for packaging can be recycled. You are therefore recommended to dis­

pose of them in special differentiated waste collection containers.

• At the end of its working life, consign the appliance to a specialist collection centre.

• lf the power cable is damaged, it must be replaced by the manufacturer or an authorised

technical service centre in arder to avoid all risk.

• This appliance is not intended far use by persons (including children) with reduced physical,

sensory or mental capabilities, or lack of experience and knowledge, unless they have been

given supervision or instruction concerning use of the appliance by a person responsible far

their safety.  Children should be supervised to ensure that they do not play with the appliance.

Summary of Contents for Giatsu GIA-PC-09P15

Page 1: ......

Page 2: ...4 Description Of The Display Screen 5 Operating From The Control Panel 5 Self diagnosis 8 Manual of Remate control 9 Tips Far Correct Use 12 Water Drainage Method 12 Cleaning 14 Start End Of Season O...

Page 3: ...sulphur Do not install near sour ces of heat Keep the appliance at least 50 cm away from flammable substances alcohol etc or pres surised containers eg aerosol cans Do not rest heavy or hot objects o...

Page 4: ...erials to be recove red to obtain significant savings in energy and resources As a reminder of the need to dispose of household appliances separately the product is marked with a crossed out wheeled d...

Page 5: ...le 6 Castors 7 Control panel 8 lntake grille 9 Air exhaust hose housing 10 Condensar drain 11 Power cable 12 Air exhaust hose 13 Hose outlet 14 Hose inlet 15 Castor locks 16 Suckers 17 Window slider 1...

Page 6: ...ndow ar French window Adjust the length of the hose to reach the window Make sure the air exhaust hose is unobstructed Open the window ar French window slightly and position the outlet fig 2 lf you ha...

Page 7: ...ol 6 Temperature indicator OPERATING FROM THE CONTROL PANEL The control panel is on the top of the appliance enables you to manage part functions without remate controller but to fully exploit its pot...

Page 8: ...ailable Maximum speed to achieve the target tempe rature as rapidly as possible Medium speed reduces noise levels but still maintains a good level of comfort Low speed for silent operation u L I The m...

Page 9: ...ng the appliance in this mode the air hose does not need to be attached To set this mode correctly Press the M button a number of times until the symbol appears Select the required fan speed by pressi...

Page 10: ...number of malfunctions Error messages are displayed on the appliance display 1F IS DISPLAYED 111 Low TEMPERATURE frost prevention PROBE FAILURE sensor damaged 111 FULL TANK safety tank full WHAT SHOU...

Page 11: ...en legislation as they are harmful to the environment TURNING THE APPLIANCE ON Plug into the mains socket then the appliance is standby Press he button to make he appliance turn on The las function ac...

Page 12: ...play The tank cap mus be extracted and emptied Run off all water left into a basin When all the water has been drained pul the cap back in place When the tank has been emptied the appliance starts up...

Page 13: ...s another 1 C alter 2 hours and then keeps the same in following period Switch the unit of temperatura In cooling or heating mode press he C F bullan can change he unit of temperature Far example Befa...

Page 14: ...use the appliance outdoors Make sure the air conditioner is standing on a level surface if necessary place the castor locks under the front wheels WATER DRAINAGE METHOD clase doors and windows curtain...

Page 15: ...from he front until no more water drains from the outlet Restar he air conditioner by pressing he on off bullan Ensure that he unit is in COOL DRY or HEAT mode The compressor will start approximately...

Page 16: ...ance v Never spray insecticide liquids or similar CLEANING THE AIR FILTERS To keep your air conditioner working efficiently you should clean the filter every week of operation The evaporator filter ca...

Page 17: ...cap fig 32 Run off all water left into a basin When all the water has been drained put the cap back in place Clean the filter and dry thoroughly before putting back TECHNICAL SPECIFICATIONS Mains vol...

Page 18: ...e technical specification of he appliance is not adequa te for he room in which it is located airfilter clogged he interna compressor safety device prevents the applian ce from being restarted until t...

Page 19: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 0034 93 390 42 20 Fax 0034 93 390 42 05 info giatsu com www giatsu com...